RX9362.215 Rittal RilineX NH fuse-switch disconnector 400A, 3-pole

RX9362.215 Rittal RilineX NH fuse-switch disconnector 400A, 3-pole

Rittal RX9362.215 RiLineX NH size 2 fuse switch disconnector featuring a 400 A rating, 690 V AC operation, 3-pole design, M10 screw terminals and integrated electronic fuse monitoring.

SKU: RX9362.215Alt SKU: 9362215MPN: RX9362.215
Price
List Price £367.42 ex VAT
Your Price (ex VAT) Save 15%
£312.31 15% OFF
You save £55.11 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £312.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£312.31

Why Choose the Rittal RX9362.215 RiLineX NH Fuse Switch Disconnector?

The Rittal RX9362.215 is a high performance NH fuse switch disconnector engineered for safe switching, circuit isolation and overcurrent protection in industrial low-voltage power distribution systems. As part of the advanced Rittal RiLineX power distribution platform, it delivers reliable performance, flexible installation and seamless integration into modern switchgear and control panel assemblies.

Designed for NH size 2 fuse links, the RX9362.215 features integrated electronic fuse monitoring, visual fuse indication, dedicated voltage measuring points and a lockable cover prepared for lead sealing. A built-in maintenance park position allows safer servicing, while the cable outlet can be configured at either the top or bottom without tools for maximum installation flexibility.

With a 400 A rated operating current, 690 V AC rated operating voltage and a robust three-pole configuration, the RX9362.215 is ideal for industrial switchboards, motor control centres, machinery panels and OEM power distribution systems requiring dependable protection and safe isolation.

Key Advantages

  • Heavy-duty NH fuse switch disconnector for industrial power distribution.
  • 400 A rated operating current for demanding applications.
  • Suitable for NH size 2 fuse links.
  • Integrated electronic and visual fuse monitoring.
  • Compatible with Rittal RiLineX and RiLine60 busbar systems.
  • Tool-free top or bottom cable outlet conversion for flexible installation.

Key Features

  • Rittal RiLineX series.
  • 400 A rated operating current.
  • 690 V AC rated operating voltage.
  • Three-pole configuration.
  • NH size 2 fuse compatibility.
  • M10 screw terminal connection.
  • Integrated electronic fuse monitoring supplied as standard.
  • Suitable for RiLineX and RiLine60 60 mm busbar systems.

Reliable Protection for Industrial Power Distribution

NH fuse switch disconnectors provide a safe means of switching, isolating and protecting electrical distribution circuits against overloads and short circuits. They enable maintenance to be carried out safely while helping to maximise equipment uptime and system reliability.

The RiLineX platform has been engineered to simplify switchgear construction while improving operational safety. Integrated measuring points, electronic fuse monitoring, visual fuse indication and a maintenance park position help reduce installation and servicing time in demanding industrial environments.

Typical Applications

  • Industrial power distribution systems.
  • Low-voltage switchgear assemblies.
  • Motor control centres.
  • Machine control panels.
  • OEM electrical equipment.
  • Commercial and industrial electrical installations.

Technical Specifications

Tick the specs you need, then view products that match.

Product Series Rittal RiLineX
Device Type Terminal / feed-in
Current 400 A
Phase Three Phase
Poles 3-pole
Manufacturer Rittal
Series RiLineX
Model RX9362.215
Product type NH fuse switch disconnector
Rated operating current 400 A
Rated operating voltage 690 V AC
High voltage ready Up to 800 V
Fuse size NH 2
Number of poles 3
Electrical connection M10 screw terminal
Cable outlet Top / bottom
Protection rating IP2XB
Compatible busbar systems RiLineX, RiLine60
Busbar centre spacing 60 mm
Dimensions (H × W × D) approx. 349 × 209 × 135 mm
Operating temperature -5 °C to +35 °C
Storage temperature -25 °C to +70 °C
Maximum power loss 98 W
Weight approx. 4.2 kg
HS Code 85369095

Frequently Asked Questions

What is the Rittal RX9362.215 used for?

It is an NH fuse switch disconnector used for switching, isolating and protecting industrial low-voltage electrical distribution circuits.

Which fuse size is compatible with the RX9362.215?

The unit is designed for NH size 2 fuse links.

What is the rated operating current?

The RX9362.215 has a maximum rated operating current of 400 A.

Does the unit include electronic fuse monitoring?

Yes. The disconnector is supplied with integrated electronic and visual fuse monitoring together with voltage measuring points.

Which busbar systems is it compatible with?

The RX9362.215 is designed for use with Rittal RiLineX and RiLine60 60 mm busbar systems.

Trusted by Panel Builders Worldwide

Rittal RiLineX power distribution components are trusted worldwide by switchgear manufacturers, OEMs and industrial engineers for delivering safe, efficient and dependable electrical power distribution.