RX9360.525 Rittal RilineX CB component adaptor 400A, 3-pole, Easy Fix

RX9360.525 Rittal RilineX CB component adaptor 400A, 3-pole, Easy Fix

Rittal RX9360.525 Easy-Fix 3-pole CB component adaptor for mounting compatible moulded-case circuit breakers up to 400 A on RiLineX and RiLine60 60 mm busbar systems.

SKU: RX9360.525Alt SKU: 9360525MPN: RX9360.525
Price
List Price £187.69 ex VAT
Your Price (ex VAT) Save 15%
£159.54 15% OFF
You save £28.15 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £159.54
Trade pricing is personalised to your account

Manufacturer Lead Time

£159.54

Why Choose the Rittal RX9360.525 RiLineX CB Component Adaptor?

The Rittal RX9360.525 is a heavy-duty 3-pole RiLineX CB component adaptor designed for mounting moulded-case circuit breakers directly onto RiLineX and RiLine60 60 mm busbar systems. Rated for currents up to 400 A, it provides a robust and efficient solution for integrating larger MCCBs into industrial switchgear and power distribution assemblies.

Featuring Rittal's Easy-Fix design, the RX9360.525 allows the circuit breaker and adaptor to be assembled independently outside the enclosure. The completed assembly can then be installed onto the busbar system using tool-free snap-on mounting, helping panel builders reduce wiring time, simplify production and improve installation consistency.

The adaptor automatically accommodates busbars with thicknesses of 5 mm or 10 mm and provides a convertible cable outlet for top or bottom connection. It supports a wide range of MCCBs from leading manufacturers, including ABB, Eaton, Schneider Electric, Siemens, Mitsubishi Electric, Hager, LS Electric and Rockwell Automation.

Key Advantages

  • Direct mounting of moulded-case circuit breakers onto the busbar system.
  • Maximum rated current of 400 A.
  • Easy-Fix design supports convenient external MCCB pre-assembly.
  • Tool-free snap-on mounting for faster panel construction.
  • Semi-automatic adjustment for 5 mm and 10 mm busbar thicknesses.
  • Convertible top or bottom cable outlet.
  • Compatible with RiLineX and RiLine60 busbar systems.
  • Suitable for MCCBs from numerous leading manufacturers.
  • Touch-safe construction providing IP2XB protection.

Key Features

  • Rittal RiLineX CB component adaptor.
  • 3-pole Easy-Fix configuration.
  • Designed for moulded-case circuit breakers up to 400 A.
  • Tool-free snap-on installation.
  • Screw M10 electrical connection.
  • Compatible with 15 mm, 20 mm and 30 mm-wide busbars.
  • Suitable for busbar thicknesses of 5 mm and 10 mm.
  • Top or bottom cable outlet.
  • Includes three terminal covers.
  • Polyamide PA 6 construction with UL 94 fire performance.

Efficient 400 A MCCB Installation with Easy-Fix Technology

The RX9360.525 enables the circuit breaker to be installed on the component adaptor before the complete assembly is fitted inside the enclosure. This external pre-assembly approach provides easier access to the fixing points, supports repeatable production processes and helps reduce the time required to build complex power distribution panels.

Once assembled, the adaptor snaps onto the busbar system without tools and adjusts to either 5 mm or 10 mm-thick busbars. Its M10 electrical connection, high current rating and integrated terminal covers make it particularly suitable for demanding feeder, distribution and machine-control applications.

Compatible MCCB Manufacturers and Models

The Rittal RX9360.525 supports selected moulded-case circuit breakers from numerous established manufacturers. Compatible ranges include models from:

  • ABB: S5, S5 400, T5, XT5, FG400 and FG630.
  • Chint: NM8N-400, NM8N-630, NXM-400S, NXM-630S, NXMS-400 and NXMS-630.
  • Eaton: NZM3.
  • Fuji Electric: BW400 series.
  • Hager: X630.
  • Hyundai Electric: 400AF, 400 and 630AF.
  • LS Electric: 400AF, TS400 and TS630.
  • Mitsubishi Electric: NF400-SW and NF630-SW.
  • OEZ: BH630.
  • Rockwell Automation: 140G-K0F3-D40 and 140G-M0F3-D63.
  • Schneider Electric: NSX400 and NSX630.
  • Schrack: MC3.
  • Siemens: 3VA23 and 3VA24.
  • Terasaki: S400, E630 and S630.

Circuit breaker compatibility should always be confirmed against the latest Rittal component adaptor selection guide before installation.

Typical Applications

  • Industrial low-voltage switchgear assemblies.
  • Moulded-case circuit breaker mounting.
  • Main feeder and outgoing circuit protection.
  • Power distribution boards.
  • Motor control centres.
  • Machine-building and OEM control systems.
  • Manufacturing and process automation installations.
  • RiLineX and RiLine60 busbar systems.

Technical Specifications

Tick the specs you need, then view products that match.

Product Series Rittal RiLineX
Busbar Centre Distance (mm) 60 mm
Device Type Component adapter
Current 400 A
Phase Three Phase
Poles 3-pole
Manufacturer Rittal
Series RiLineX
Model RX9360.525
Article number 9360525
Product type CB component adaptor
Design Easy Fix
Number of poles 3
Maximum rated current 400 A
UL rated current 400 A
Rated voltage 690 V AC / 690 V DC
UL rated voltage 600 V AC
Rated insulation voltage 1,000 V
Rated impulse withstand voltage 12 kV
Overvoltage category IV
Pollution degree 3
Electrical connection Screw M10
Laminated copper bar clamping area 29 × 6 mm
Cable outlet Top or bottom
Compatible busbar systems RiLineX and RiLine60
Busbar spacing 60 mm
Compatible busbar sizes 15 × 5/10 mm, 20 × 5/10 mm and 30 × 5/10 mm
Fundamental frequency 50–60 Hz
Protection rating IP2XB
Material Polyamide PA 6
Fire performance Corresponding to UL 94
Colours RAL 9005 and RAL 35745
Operating temperature -25°C to +55°C
Storage temperature -25°C to +75°C
Permissible humidity 10–90%, non-condensing
Width 145 mm
Height 325.8 mm
Net weight 4 kg
Gross weight 4.298 kg
Copper content 1.652 kg per unit
Pack quantity 1 piece
Customs tariff number 85369095
ETIM classification EC001531
EAN 4028177997127
Approvals UL and C-UL Listed
HS Code 85369095

Frequently Asked Questions

What is the Rittal RX9360.525 used for?

It is used to mount compatible moulded-case circuit breakers directly onto RiLineX and RiLine60 busbar systems with 60 mm busbar spacing.

What is the maximum rated current?

The RX9360.525 has a maximum rated current of 400 A under both IEC and UL specifications.

Which busbar sizes are compatible?

The adaptor is suitable for 15 mm, 20 mm and 30 mm-wide busbars with thicknesses of either 5 mm or 10 mm.

Can the cable outlet be positioned at the top or bottom?

Yes. The cable outlet can be converted to either the top or bottom to suit the switchboard layout.

Which circuit breaker brands are supported?

The adaptor supports selected MCCBs from ABB, Chint, Eaton, Fuji Electric, Hager, Hyundai Electric, LS Electric, Mitsubishi Electric, OEZ, Rockwell Automation, Schneider Electric, Schrack, Siemens and Terasaki.

What does the Easy-Fix design provide?

Easy-Fix allows the circuit breaker and adaptor to be assembled outside the enclosure before the complete assembly is snapped onto the busbar system.

Trusted for High-Current Circuit Protection

Rittal RiLineX Easy-Fix component adaptors help panel builders integrate high-current moulded-case circuit breakers quickly, safely and consistently within modern industrial power distribution systems.