32722 Wohner busbar adapter 1320 A

32722 Wohner busbar adapter 1320 A

Wöhner 32722 EQUES 185Power 1320 A busbar adapter with bottom clamp connection for ABB Tmax T7, XT7, Emax E1.2 and Siemens 3VA27 circuit breakers.

SKU: 32722Alt SKU: 32722000AMPN: 32722000A
Price
List Price £1,890.37 ex VAT
Your Price (ex VAT) Save 20%
£1,512.30 20% OFF
You save £378.07 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,512.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,512.30

Why Choose the Wöhner 32722 EQUES 185Power Busbar Adapter?

The Wöhner 32722 is a high-performance 1320 A busbar adapter designed for integrating large-frame circuit breakers into the Wöhner EQUES 185Power busbar system. Also identified by the manufacturer part number 32722000A, this adapter provides a secure, space-saving and reliable connection for demanding industrial power distribution applications.

Designed with a bottom clamp connection and changed phase arrangement, the adapter is compatible with ABB Tmax T7 (1600 A), ABB XT7 (1600 A), ABB Emax E1.2 (1600 A) and Siemens 3VA27 (1600 A) circuit breakers. It supports copper busbars measuring 30, 40, 60, 80, 100 and 120 × 10 mm, providing excellent flexibility across a wide range of switchboard designs.

With a rated current of 1320 A, halogen-free construction and compliance with IEC 61439-1 and UL 508 requirements, the Wöhner 32722 is an ideal solution for OEM panel builders, industrial control systems and commercial low-voltage distribution assemblies.

Key Advantages

  • High-capacity 1320 A busbar adapter for demanding applications.
  • Designed specifically for the Wöhner EQUES 185Power system.
  • Compatible with ABB Tmax T7, XT7, Emax E1.2 and Siemens 3VA27 1600 A circuit breakers.
  • Bottom clamp connection provides secure installation.
  • Supports multiple copper busbar sizes from 30 × 10 mm to 120 × 10 mm.
  • Halogen-free construction for safer switchboard installations.

Key Features

  • Wöhner EQUES 185Power busbar adapter.
  • 1320 A rated current.
  • Bottom clamp connection.
  • Changed phase arrangement.
  • Suitable for ABB Tmax T7 (1600 A).
  • Suitable for ABB XT7 (1600 A).
  • Suitable for ABB Emax E1.2 (1600 A).
  • Suitable for Siemens 3VA27 (1600 A).
  • Compatible with 30, 40, 60, 80, 100 and 120 × 10 mm copper busbars.

Reliable High-Current Power Distribution

The Wöhner 32722 provides a secure mechanical and electrical interface between high-current moulded case circuit breakers and the EQUES 185Power busbar system. By mounting the breaker directly onto the busbar system, installation time is reduced while improving panel layout and reducing conventional cable connections.

Its modular design supports modern industrial switchgear requiring compact construction, high reliability and simplified maintenance. Compatibility with multiple ABB and Siemens breaker ranges makes it a versatile choice for OEMs, panel builders and electrical contractors.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main power distribution systems.
  • Motor control centres.
  • Commercial electrical installations.
  • OEM machinery and automation equipment.
  • Industrial distribution panels.

Technical Specifications

Tick the specs you need, then view products that match.

Current 1320 A
Rail / Busbar Profile 100 × 10 mm, 120 × 10 mm, 30 × 10 mm, 40 × 10 mm, 60 × 10 mm, 80 × 10 mm
Product Series Wöhner 185Power
Device Type Component adapter
Busbar Centre Distance (mm) 185 mm
Manufacturer Wöhner
Series EQUES 185Power
Model 32722
Alternative SKU 32722000A
Product type Busbar adapter
Rated current 1320 A
Rated operating voltage (IEC AC/DC) 800 V
Rated insulation voltage 1000 V
Rated impulse withstand voltage 12 kV
Connection type Bottom clamp connection
Phase arrangement Changed phase
Compatible circuit breakers ABB Tmax T7 (1600 A), ABB XT7 (1600 A), ABB Emax E1.2 (1600 A), Siemens 3VA27 (1600 A)
Compatible busbars 30, 40, 60, 80, 100 and 120 × 10 mm
Busbar spacing 185 mm
Dimensions (W × H × D) 300 × 652 × 76 mm
Material Halogen free
Standards IEC 61439-1:2020, UL 508
UL Type EQ185-A1600-C
EAN 4021267327224
Pack quantity 1

Frequently Asked Questions

What is the Wöhner 32722 used for?

The Wöhner 32722 is a 1320 A busbar adapter used to mount compatible ABB and Siemens circuit breakers directly onto the Wöhner EQUES 185Power busbar system.

Which circuit breakers are compatible with the 32722?

It is compatible with ABB Tmax T7 (1600 A), ABB XT7 (1600 A), ABB Emax E1.2 (1600 A) and Siemens 3VA27 (1600 A) circuit breakers.

What busbar sizes are supported?

The adapter supports copper busbars measuring 30, 40, 60, 80, 100 and 120 mm wide with a thickness of 10 mm.

What is the rated current?

The Wöhner 32722 has a rated current of 1320 A.

Which standards does the adapter comply with?

The adapter complies with IEC 61439-1:2020 and UL 508 and is approved for UL feeder circuits above 250 V.