2CPX041418R9999 ABB MA390T XT1/3 Expansion 3PW

2CPX041418R9999 ABB MA390T XT1/3 Expansion 3PW

ABB MA390T 2CPX041418R9999 is a three-panel-width CombiLine N expansion module for up to three fixed-mounted ABB Tmax XT1 or XT3 circuit breakers, with 699 mm useful width and a maximum rated current of 250 A.

SKU: 2CPX041418R9999Alt SKU: MA390TMPN: 2CPX041418R9999
Price
List Price £255.83 ex VAT
Your Price (ex VAT) Save 25%
£191.87 25% OFF
You save £63.96 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £191.87
Trade pricing is personalised to your account

Manufacturer Lead Time

£191.87

Why Choose the ABB MA390T XT1/3 Expansion 3PW?

The ABB MA390T, order code 2CPX041418R9999, is a mounted CombiLine N Tmax circuit breaker expansion module designed for ABB electrical sub-distribution systems. Part of the DESUJ Sub Distribution product group, it provides a purpose-designed installation platform for fixed-mounted ABB Tmax XT1 and XT3 moulded-case circuit breakers within professional low-voltage distribution cabinets.

The MA390T has a 2 RE / 300 mm height and a three-panel-width / 750 mm width, providing 72 space units. It is supplied unequipped and provides installation capacity for up to three ABB Tmax XT1 or XT3 circuit breakers, including compatible three- and four-pole configurations, with a generous 699 mm useful equipment width.

Designed for applications with a maximum rated current of 250 A, the MA390T incorporates a mounting cross beam with M4 slide nuts for secure circuit-breaker installation. Plastic covers with equipment cut-outs, 90-degree press-and-turn closures and a RAL 7035 light-grey finish complete the assembly, while the module is designed for installation on an ABB WR mounting frame in cabinets from 275 mm depth.

Key Advantages

  • Purpose-designed Tmax XT1/XT3 circuit breaker expansion module for ABB CombiLine N systems.
  • Provides installation capacity for up to three ABB Tmax XT1 or XT3 circuit breakers.
  • Suitable for compatible 3-pole and 4-pole fixed-mounted circuit breakers.
  • Maximum rated current of 250 A.
  • Generous 699 mm useful equipment width.
  • Three-panel-width, 750 mm design with 72 space units.
  • Mounting cross beam with M4 slide nuts supports secure equipment installation.
  • Designed for integration with an ABB WR mounting frame.

Key Features

  • ABB CombiLine N interior expansion system.
  • MA390T Tmax XT1/XT3 expansion module.
  • 2 RE / 300 mm module height.
  • 3 panel widths / 750 mm overall width.
  • 72 space units.
  • 699 mm useful equipment width.
  • 687 mm cover cut-out width.
  • Unequipped for installation of up to three Tmax XT1 or XT3 circuit breakers.
  • Supports fixed-mounted 3-pole and 4-pole devices.
  • 250 A maximum rated current.
  • Mounting cross beam with M4 slide nuts.
  • Plastic covers with equipment cut-outs.
  • Remaining unused cover openings can be closed with suitable cover strips.
  • 90-degree press-and-turn closures.
  • Light-grey RAL 7035 finish.
  • Suitable from a minimum cabinet depth of 275 mm.
  • Designed for an ABB WR mounting frame.

Structured Tmax XT1 and XT3 Circuit Breaker Integration

Moulded-case circuit breakers provide switching, isolation and overcurrent protection for higher-current distribution circuits. The ABB MA390T provides a coordinated mounting platform for fixed-mounted Tmax XT1 and XT3 devices, with installation capacity for up to three compatible circuit breakers across its three-panel-width CombiLine N configuration.

With a 699 mm useful equipment width, 72 space units and a maximum rated current of 250 A, the MA390T is suited to commercial and industrial distribution assemblies requiring multiple MCCBs within a structured cabinet layout. Its mounting cross beam, M4 slide nuts and 687 mm equipment cut-out provide a practical installation interface, while the WR mounting-frame format supports robust cabinet construction.

Typical Applications

  • Commercial and industrial sub-distribution boards.
  • ABB Tmax XT1 and XT3 circuit breaker installations.
  • Multiple outgoing feeder protection applications.
  • Incoming and distribution circuit protection.
  • Electrical distribution cabinets and switchboards.
  • Low-voltage circuit protection and isolation.
  • ABB CombiLine N cabinet expansion and interior fit-out.

Technical Specifications

Tick the specs you need, then view products that match.

Current 250 A
Product Series S&J CombiLine N
Device Type Mounting / Expansion Module
Series CombiLine N
Order code 2CPX041418R9999
Product group DESUJ Sub Distribution
Product type Tmax circuit breaker expansion module
Configuration Mounted and installed in cabinet
Equipment supplied Unequipped
Compatible equipment ABB Tmax XT1 and XT3
Installation type Fixed mounted
Supported poles 3-pole or 4-pole
XT1 width 76.2 mm (3-pole) / 101.2 mm (4-pole)
XT3 width 105 mm (3-pole) / 140 mm (4-pole)
Installation capacity Up to 3 circuit breakers
Maximum rated current 250 A
Number of poles 4
Grid units 2 RE
Module height 300 mm
Field width 3 panel widths
Overall width 750 mm
Overall depth 260 mm
Space units 72
Useful equipment width 699 mm
Cover cut-out width 687 mm
Minimum cabinet depth 275 mm
Mounting equipment Cross beam with M4 slide nuts
Mounting frame WR
Cover material Plastic
Cover design With cut-out
Closure 90-degree press-and-turn closure
Colour Light grey / RAL 7035
Fire-protection housing suitability Not suitable
Commodity code 85381000
EAN / GTIN 4011617414186
Country of origin Germany

Frequently Asked Questions

What is the ABB MA390T used for?

The ABB MA390T is a CombiLine N Tmax circuit breaker expansion module designed for integrating fixed-mounted ABB Tmax XT1 and XT3 moulded-case circuit breakers into professional electrical sub-distribution cabinets.

How many circuit breakers can the ABB MA390T accommodate?

The MA390T provides installation capacity for up to three ABB Tmax XT1 or XT3 circuit breakers in compatible three- or four-pole fixed-mounted configurations.

What is the maximum rated current of the ABB MA390T?

The MA390T supports a maximum rated current of 250 A.

How much useful installation width does the ABB MA390T provide?

The MA390T provides 699 mm of useful equipment width and a 687 mm cover cut-out within its three-panel-width, 750 mm-wide configuration.

Which mounting frame is compatible with the ABB MA390T?

The MA390T is designed for installation on an ABB WR mounting frame. The mounting frame must be ordered separately, and the module is suitable for cabinets from 275 mm depth.

Trusted ABB Distribution System Engineering

ABB CombiLine N Tmax expansion modules provide structured mounting solutions for professional low-voltage distribution assemblies, supporting dependable circuit protection, switching and organised cabinet construction.