ABB EPH-S66209-AF Protecta Home 9-way AFDD-compatible steel consumer unit featuring 18 modular positions, a 63 A main switch isolator, two 63 A RCCBs and a variable split-load arrangement in a 250 x 490 x 105 mm enclosure.
£263.04
The ABB EPH-S66209-AF is a 9-way, 63 A AFDD-compatible split-load consumer unit from the ABB Protecta Home range, designed for residential and light commercial electrical distribution. Featuring a 63 A main switch isolator and two 63 A residual current circuit breakers (RCCBs), this consumer unit combines central supply isolation with two separately protected residual current circuit groups.
Designed specifically for installations incorporating arc fault detection devices (AFDDs), the EPH-S66209-AF provides 9 outgoing circuit ways and 18 modular positions. Its AFDD-compatible layout accommodates the additional modular space required by suitable protective devices, making it a practical solution for electrical installations where arc fault protection forms part of the circuit design.
Housed in a robust steel enclosure measuring 250 × 490 × 105 mm, the ABB EPH-S66209-AF combines a compact single-row arrangement with flexible circuit distribution. Its two 63 A RCCBs, 63 A main switch and AFDD-ready configuration make it suitable for professionally designed electrical installations using compatible ABB circuit protection equipment.
The ABB EPH-S66209-AF is designed for electrical installations requiring the flexibility to incorporate arc fault detection devices alongside conventional circuit protection equipment. AFDDs are designed to detect characteristic electrical arcing conditions that may present a fire risk and disconnect the affected circuit when their specified operating criteria are met.
Unlike a conventional consumer unit designed primarily around single-module miniature circuit breakers, the EPH-S66209-AF provides 18 modular positions for 9 outgoing ways. This arrangement allows additional space for compatible AFDD-based protection devices, helping electricians plan circuits where arc fault detection is required or specified.
The consumer unit includes a 63 A main switch isolator, providing a central means of disconnecting the incoming supply. Downstream of the main switch, two 63 A RCCBs establish separate residual current protection groups. These groups allow outgoing circuits to be distributed according to the approved split-load arrangement.
The two RCCBs provide residual current protection for their respective circuit groups. Their 63 A ratings describe current-carrying capacity rather than residual current operating sensitivity. The actual residual current trip characteristics must be confirmed from the installed device specifications.
Importantly, RCCBs, MCBs and AFDDs perform different protective functions. RCCBs detect residual current imbalance, MCBs provide overcurrent protection, and AFDDs detect specified arcing faults. The protective functions available on an individual outgoing circuit depend on the exact combination or integrated type of protective devices selected.
The AF designation identifies the consumer unit's AFDD-compatible configuration; it does not establish that separate AFDD protective devices are included. Suitable AFDDs and other outgoing circuit protection devices should be selected according to ABB compatibility guidance and the electrical installation design.
The variable split-load arrangement allows circuit allocation between the two RCCB groups, subject to the approved busbar and device configuration. This can support improved organisation of electrical circuits, although a residual current fault on one circuit may still disconnect other circuits connected to the same RCCB.
With its steel enclosure and nominal dimensions of 250 × 490 × 105 mm, the EPH-S66209-AF provides a practical platform for indoor electrical distribution. Final device selection, circuit grouping, conductor sizing and installation methods must follow ABB instructions and applicable electrical installation regulations, including relevant BS 7671 requirements.
Tick the specs you need, then view products that match.
| Material | Steel | |
|---|---|---|
| Product Series | ABB Protecta Home | |
| Device Type | Consumer Unit | |
| Incomer | Main switch / isolator + 2× RCCB + AFDD | |
| Number of Outgoing Ways | 9 | |
| Current | 63 A | |
| Product range | Protecta Home | |
| Manufacturer description | EPH-S66209-AF 9W 63A ISO 2x63A RC AF | |
| Product type | AFDD-compatible split-load RCCB consumer unit | |
| ABB order code | 1TVC151800S3086 | |
| Product group | Protecta Home | |
| Number of outgoing ways | 9 | |
| Total modular capacity | 18 modules | |
| Consumer unit configuration | AFDD-compatible split load | |
| ABB configuration designation | AFSL | |
| Main switch type | Switch disconnector / isolator | |
| Main switch rated current | 63 A | |
| Number of RCCBs | 2 | |
| First RCCB rated current | 63 A | |
| Second RCCB rated current | 63 A | |
| RCCB configuration | 2 × 63 A | |
| Residual current protection groups | 2 | |
| Outgoing circuit arrangement | Variable RCCB split | |
| AFDD compatibility | Designed for compatible arc fault detection devices | |
| Enclosure material | Steel | |
| Enclosure arrangement | Single row | |
| Nominal height | 250 mm | |
| Nominal width | 490 mm | |
| Nominal depth | 105 mm | |
| Nominal dimensions (H × W × D) | 250 × 490 × 105 mm | |
| Installation application | Residential and light commercial electrical distribution | |
| Outgoing circuit protection | Compatible devices selected separately according to installation requirements | |
| Manufacturer product family | Protecta Home AFDD-compatible consumer units |
The ABB EPH-S66209-AF is a 9-way Protecta Home AFDD-compatible split-load consumer unit featuring a 63 A main switch isolator and two 63 A RCCBs. It provides 18 modular positions for compatible outgoing protection devices.
The EPH-S66209-AF provides 9 outgoing circuit ways and 18 modular positions. The additional modular capacity supports the installation of compatible AFDD-based circuit protection equipment.
Yes. The consumer unit is specified with two 63 A RCCBs and a separate 63 A main switch isolator. The RCCBs provide residual current protection for their respective circuit groups, while suitable outgoing protective devices must be selected according to circuit requirements.
The EPH-S66209-AF is an AFDD-compatible consumer unit, designed to accommodate suitable arc fault detection devices. The AF designation does not confirm that separate outgoing AFDD protective devices are supplied; these should be selected according to the required circuit configuration.
The ABB EPH-S66209-AF has nominal dimensions of 250 × 490 × 105 mm (height × width × depth). It features a steel enclosure and belongs to the ABB Protecta Home AFDD-compatible consumer unit range.
ABB Protecta Home consumer units provide flexible electrical distribution solutions for modern residential and light commercial installations. The EPH-S66209-AF combines 9 outgoing ways, 18 modular positions, a 63 A main switch isolator and two 63 A RCCBs in an AFDD-compatible split-load arrangement, supporting professional circuit protection design and organised electrical distribution.