ABB EPH-S17212 is a Protecta Home 12-way steel split-load consumer unit featuring a 100 A main switch-disconnector, one 80 A RCCB, one 63 A RCCB, a variable circuit split and nominal dimensions of 250 × 380 × 105 mm for residential electrical distribution.
£239.16
The ABB EPH-S17212 Protecta Home Consumer Unit, manufacturer order code 1TVC151800S3071, is a 12-way, 100 A main switch split-load consumer unit designed for residential low-voltage electrical distribution. Part of ABB's Protecta Home steel enclosure range, it combines a 100 A incoming isolator with two residual current circuit breakers (RCCBs), providing a coordinated foundation for domestic circuit protection.
Identified by ABB as EPH-S17212 12W 100A ISO 1x80A+63A RC, this consumer unit incorporates a 100 A main switch-disconnector, one 80 A RCCB and one 63 A RCCB. The two RCCBs provide separate residual current protection groups, allowing outgoing circuits to be distributed between independently protected sections according to the installation design.
The EPH-S17212 belongs to ABB's Protecta Home split-load (SL) consumer unit range. ABB identifies this configuration as a 100 A main switch assembly with 80 A and 63 A RCCBs, offering a variable split arrangement for its 12 outgoing circuit ways.
With nominal enclosure dimensions of 250 mm high × 380 mm wide × 105 mm deep, the ABB EPH-S17212 provides a compact distribution solution for installations requiring two RCCB-protected circuit groups. Its steel enclosure construction and coordinated ABB electrical components make it suitable for professional consumer unit assembly, refurbishment and replacement applications.
For electrical contractors and installers, the ABB 1TVC151800S3071 provides a convenient alternative to a main switch-only consumer unit where a dual-RCCB split-load arrangement is appropriate for the installation.
The ABB EPH-S17212 provides a practical electrical distribution solution where a 12-way split-load consumer unit is required. Its 100 A main switch provides central isolation, while the separate 80 A and 63 A RCCBs allow groups of outgoing circuits to benefit from residual current protection.
The dual RCCB configuration allows an electrical designer to allocate selected final circuits between two protected sections. This can help distribute circuits across separate residual current protection devices, although a fault affecting one RCCB group may disconnect all circuits supplied through that RCCB.
The 80 A and 63 A ratings identify the rated currents of the two RCCBs. They do not specify the residual operating current or the RCCB type. Those characteristics must be confirmed from the actual devices and manufacturer documentation before installation.
Unlike an RCBO, an RCCB does not provide individual circuit overcurrent protection. Each outgoing circuit must therefore have suitable overcurrent protection, typically through a compatible miniature circuit breaker selected for the circuit's design current, cable characteristics and fault protection requirements.
ABB describes the Protecta Home RCCB split-load consumer units as having a variable split arrangement. This allows the number of outgoing ways assigned to each RCCB section to be planned according to the installation requirements, subject to the manufacturer's approved busbar and assembly arrangements.
The 100 A incoming switch-disconnector provides a central means of isolating the consumer unit. Its rated current must not be confused with the separate RCCB current ratings or the permissible loading of individual outgoing circuits.
The EPH-S17212 uses a steel enclosure with nominal dimensions of 250 × 380 × 105 mm. The enclosure width accommodates the incoming switching arrangement, two RCCBs and the specified outgoing circuit capacity, making it important to allow adequate wall space and suitable cable entry arrangements.
Correct circuit allocation is essential in a split-load consumer unit. Each circuit's live and neutral conductors must be associated with the correct RCCB group, and neutral connections must not be interchanged between independently protected sections. Incorrect neutral allocation can cause unwanted tripping or compromise the intended protection arrangement.
For residential installations in the United Kingdom, the completed assembly must comply with the relevant requirements of BS 7671, including appropriate residual current protection, overcurrent protection, isolation, circuit identification and verification.
The ABB EPH-S17212 is particularly suitable where a conventional dual-RCCB split-load arrangement is appropriate. Installers should assess whether the circuit requirements call for additional measures, such as individual RCBO protection, surge protection or arc fault detection, before finalising the distribution board design.
Tick the specs you need, then view products that match.
| Material | Steel | |
|---|---|---|
| Device Type | Distribution Board | |
| Incomer | Main switch / isolator + RCCB | |
| Number of Outgoing Ways | 12 | |
| Current | 100 A | |
| Product Series | ABB Protecta Home | |
| Product group | Protecta Home | |
| Product range | Protecta Home Consumer Units | |
| Product series | Protecta Home SL | |
| Model / type | EPH-S17212 | |
| ABB manufacturer order code | 1TVC151800S3071 | |
| Manufacturer description | EPH-S17212 12W 100A ISO 1x80A+63A RC | |
| Product category | Residential consumer units | |
| Consumer unit configuration | Main switch with dual RCCB split load | |
| Number of outgoing ways | 12 | |
| Incoming main switch rated current | 100 A | |
| Incoming device function | Isolation / switching | |
| Number of RCCBs | 2 | |
| First RCCB rated current | 80 A | |
| Second RCCB rated current | 63 A | |
| RCCB combination | 1 × 80 A + 1 × 63 A | |
| Residual current protection configuration | Two RCCB-protected groups | |
| Split arrangement | Variable split | |
| Enclosure material | Steel | |
| Nominal enclosure height | 250 mm | |
| Nominal enclosure width | 380 mm | |
| Nominal enclosure depth | 105 mm | |
| Nominal dimensions (H × W × D) | 250 × 380 × 105 mm | |
| Outgoing circuit protection | Compatible protective devices selected to suit the installation | |
| Primary application | Residential low-voltage electrical distribution | |
| Manufacturer product family | ABB Protecta Home steel consumer units |
The ABB EPH-S17212 is a 12-way Protecta Home split-load consumer unit with a 100 A main switch, one 80 A RCCB and one 63 A RCCB, designed for residential electrical distribution.
The ABB manufacturer order code is 1TVC151800S3071, and the product model designation is EPH-S17212.
The EPH-S17212 provides 12 outgoing circuit ways, which can be allocated between the two RCCB-protected sections according to the approved split-load arrangement.
The consumer unit features a 100 A main switch-disconnector, providing a central means of isolation for the distribution assembly.
The EPH-S17212 includes two RCCBs: one rated at 80 A and one rated at 63 A.
It identifies the consumer unit's two residual current circuit breakers: one 80 A RCCB and one 63 A RCCB. These are used to provide separate residual current protection groups within the split-load arrangement.
A split-load consumer unit divides outgoing circuits into separate groups controlled by different residual current protection devices. The ABB EPH-S17212 uses an 80 A RCCB and a 63 A RCCB for this purpose.
ABB specifies nominal enclosure dimensions of 250 mm high × 380 mm wide × 105 mm deep.
The specified configuration includes the 100 A main switch and two RCCBs. Individual outgoing MCBs are not identified in the product description and should be selected according to the circuit protection requirements.
No. An RCCB provides residual current protection but does not replace the overcurrent protection required for outgoing circuits. Suitable circuit breakers must be incorporated into the installation.
ABB identifies the Protecta Home RCCB split-load range as having a variable split arrangement. The final circuit allocation must follow the manufacturer's approved configuration and the electrical installation design.
Both models are 12-way Protecta Home split-load consumer units with a 100 A main switch. The EPH-S16212 has two 63 A RCCBs, while the EPH-S17212 has one 80 A RCCB and one 63 A RCCB.
Both models use a 100 A main switch with 80 A and 63 A RCCBs. The EPH-S17208 provides 8 outgoing ways, while the EPH-S17212 provides 12 outgoing ways and a wider enclosure.
Yes. The EPH-S17212 belongs to ABB's Protecta Home residential consumer unit range. It must be configured and installed by a competent electrician in accordance with the applicable electrical installation regulations.
Yes, where its 12-way capacity, 100 A main switch, dual RCCB arrangement and enclosure dimensions are suitable for the installation. A qualified electrician must assess the existing circuits and required protective device configuration.
ABB Protecta Home split-load consumer units provide coordinated solutions for residential electrical distribution. The EPH-S17212 combines a 100 A main switch, 12 outgoing ways and separate 80 A and 63 A RCCB-protected sections, supporting organised circuit allocation and professional domestic electrical installation.