ABB OVR PV T1-T2 12.5-1000 P TS QS is a pluggable Type 1+2 photovoltaic surge protection device with 12.5 kA total discharge current, 6.25 kA impulse current, 40 kA maximum discharge current, 1100 V DC maximum continuous operating voltage and remote signalling for 1000 V solar PV installations.
£192.80
The ABB OVR PV T1-T2 12.5-1000 P TS QS, order code 2CTB812121R1000, is a pluggable Type 1+2 photovoltaic surge protection device (SPD) designed to protect the DC side of solar PV installations against lightning currents and transient overvoltages. As part of the ABB OVR PV QuickSafe range, it combines Type 1 lightning-current protection with Type 2 surge protection for demanding photovoltaic applications.
Designed for 1000 V DC photovoltaic systems, the OVR PV T1-T2 12.5-1000 P TS QS uses a 1+1 DC protection configuration and provides a total discharge current (Itotal) of 12.5 kA and an impulse current (Iimp) of 6.25 kA with a 10/350 µs waveform. It also provides a maximum discharge current (Imax) of 40 kA and a nominal discharge current (In) of 20 kA with an 8/20 µs waveform.
With a 1100 V DC maximum continuous operating voltage (Ucpv) and a 3.8 kV voltage protection level (Up), this SPD is engineered for modern high-voltage photovoltaic systems. The TS version includes auxiliary remote signalling, while visual status indication and pluggable QuickSafe construction support convenient monitoring, inspection and maintenance in PV combiner boxes, DC distribution panels and inverter protection applications.
Photovoltaic installations can be exposed to high-energy lightning currents and induced transient overvoltages because solar arrays are often installed in exposed locations and connected through extensive DC cabling. Type 1+2 photovoltaic SPDs combine lightning-current handling with Type 2 surge protection, helping protect sensitive DC equipment against both 10/350 µs lightning impulses and 8/20 µs transient surge currents.
The ABB OVR PV T1-T2 12.5-1000 P TS QS combines a 12.5 kA total 10/350 µs discharge capability with a 40 kA maximum 8/20 µs discharge current. Its remote signalling facility allows SPD status to be integrated into monitoring or alarm systems, making it particularly suitable for photovoltaic installations where the condition of surge protection equipment needs to be monitored without direct visual inspection.
Tick the specs you need, then view products that match.
| Impulse Current Iimp (kA) | 6.25 kA | |
|---|---|---|
| Device Type | Surge protection device | |
| SPD Type | Type 1+2 | |
| Product Series | ABB OVR PV T1-T2 QuickSafe | |
| Series | OVR PV T1-T2 QuickSafe | |
| Order code / MPN | 2CTB812121R1000 | |
| Product group | Surge Protection Devices | |
| Product type | Photovoltaic Type 1+2 surge protection device | |
| SPD classification | Type 1+2 / Class I+II | |
| Application | Photovoltaic DC systems | |
| Protection configuration | 1+1 DC | |
| Current type | DC | |
| Nominal system voltage (Un) | 1000 V DC | |
| Maximum continuous operating voltage (Ucpv) | 1100 V DC | |
| Total discharge current (Itotal, 10/350 µs) | 12.5 kA | |
| Impulse current (Iimp, 10/350 µs) | 6.25 kA | |
| Nominal discharge current (In, 8/20 µs) | 20 kA | |
| Maximum discharge current (Imax, 8/20 µs) | 40 kA | |
| Voltage protection level (Up) | 3.8 kV | |
| PV short-circuit current rating (Iscpv) | 11 kA | |
| Status indication | Visual | |
| Remote signalling | Yes | |
| Auxiliary contact | Yes | |
| Mounting type | DIN rail | |
| Protection rating | IP20 | |
| Standards | IEC 61643-11 / EN 50539-11 / UL 1449 4th Edition | |
| Dimensions (H × W × D) | 110 × 64 × 84 mm | |
| Construction | Pluggable |
The ABB OVR PV T1-T2 12.5-1000 P TS QS is a Type 1+2 photovoltaic surge protection device designed to protect the DC side of 1000 V solar PV installations against lightning-current impulses and transient overvoltages.
The device provides a 12.5 kA total discharge current (Itotal) and a 6.25 kA impulse current (Iimp) with a 10/350 µs waveform.
The OVR PV T1-T2 12.5-1000 P TS QS has a 20 kA nominal discharge current (In) and a 40 kA maximum discharge current (Imax), measured using an 8/20 µs waveform.
The device is designed for 1000 V DC photovoltaic systems and has a maximum continuous operating voltage (Ucpv) of 1100 V DC.
Yes. The TS version includes an auxiliary contact for remote signalling, allowing the status of the surge protection device to be monitored remotely in addition to its local visual status indication.
ABB OVR PV surge protection devices are designed to protect photovoltaic DC installations against lightning currents and transient overvoltages, helping safeguard PV arrays, DC distribution equipment and inverter systems while supporting effective monitoring and maintenance.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.