Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB OVR PV T1-T2 5-1500 P QS combined Type 1 and Type 2 pluggable photovoltaic surge protective device for 1500 V DC solar installations, with 5 kA impulse discharge current per protected path and 20 kA nominal discharge current.
£161.08
The ABB OVR PV T1-T2 5-1500 P QS is a combined Type 1 + Type 2 photovoltaic surge protective device (SPD) designed to protect high-voltage DC solar installations against damaging transient overvoltages and lightning surge currents. Identified by ABB order code 2CTB812050R1500, it is specifically engineered for photovoltaic applications with DC system voltages up to 1500 V DC.
As part of the ABB OVR PV QuickSafe surge protection range, this SPD provides coordinated Type 1 and Type 2 protection in a compact DIN rail format. It protects both L+ and L− photovoltaic conductors and uses pluggable protection cartridges, allowing damaged or end-of-life modules to be replaced without changing the complete installed base.
The OVR PV T1-T2 5-1500 P QS provides an impulse discharge current (Iimp) of 5 kA per protected path using a 10/350 µs waveform, a nominal discharge current (In) of 20 kA and a total 8/20 µs discharge capability of 30 kA. Its 5 kV voltage protection level and photovoltaic-specific DC design make it suitable for protecting solar arrays, combiner boxes, inverter inputs and associated DC distribution equipment.
Photovoltaic installations can be particularly exposed to transient overvoltages because of their extensive DC cabling and outdoor solar arrays. Combined Type 1 and Type 2 SPDs are designed to handle both lightning-current impulses and induced or switching surges, limiting the transient voltage transmitted towards photovoltaic inverters and other sensitive DC equipment.
The ABB OVR PV T1-T2 5-1500 P QS is designed specifically for modern high-voltage PV installations. Its 1500 V DC capability, 10/350 µs lightning-current performance and pluggable QuickSafe construction provide a practical solution for protecting photovoltaic strings, combiner equipment and inverter DC inputs while simplifying inspection and maintenance.
Tick the specs you need, then view products that match.
| Impulse Current Iimp (kA) | 5 kA | |
|---|---|---|
| Device Type | Surge protection device | |
| SPD Type | Type 1+2 | |
| Product Series | ABB OVR PV T1-T2 QuickSafe | |
| Series | OVR PV T1-T2 QuickSafe | |
| ABB order code | 2CTB812050R1500 | |
| Product group | Surge Protection Devices | |
| Product type | Photovoltaic surge protective device | |
| SPD classification | Type 1 + Type 2 | |
| Application | Photovoltaic DC systems | |
| Protection configuration | 1+1 DC | |
| Protected lines | L+ and L− | |
| Rated voltage | 1500 V DC | |
| Impulse discharge current (Iimp, 10/350 µs) | 5 kA per protected path | |
| Total impulse discharge current (Itotal) | 5 kA | |
| Nominal discharge current (In, 8/20 µs) | 20 kA | |
| 8/20 µs discharge-current capability | 30 kA | |
| Voltage protection level (Up) | 5 kV | |
| Photovoltaic short-circuit current (Iscpv) | 11 kA | |
| PV current capability (Icpv) | 50 A | |
| Short-circuit protection | No additional backup fuse required up to 11 kA Iscpv | |
| Status indicator | Yes | |
| Cartridge type | Pluggable | |
| Compatible L+ / L− replacement cartridge | OVR PV T1-T2 5-1500 C QS | |
| Replacement cartridge order code | 2CTB812052R1500 | |
| Protection rating | IP20 for indoor installation | |
| Operating temperature | -40 to +80 °C | |
| Mounting | DIN rail | |
| Terminal tightening torque (L+, L−, PE) | 4.5 N·m | |
| Standards | IEC 61643-11 / EN 50539-11 | |
| Dimensions (H × W × D) | 95 × 54 × 86 mm | |
| Weight | approx. 0.488 kg |
It is a combined Type 1 and Type 2 surge protective device designed to protect photovoltaic DC installations, solar inverters and associated equipment against lightning-current impulses and transient overvoltages.
The device is designed for high-voltage photovoltaic systems with a rated voltage of up to 1500 V DC.
The OVR PV T1-T2 5-1500 P QS provides an impulse discharge current (Iimp) of 5 kA per protected path using a 10/350 µs lightning-current waveform.
The nominal discharge current (In) is 20 kA using an 8/20 µs waveform, with a 30 kA 8/20 µs discharge-current capability.
Yes. The ABB OVR PV T1-T2 5-1500 P QS uses pluggable protection cartridges. The compatible L+ and L− replacement cartridge is the OVR PV T1-T2 5-1500 C QS, ABB order code 2CTB812052R1500.
ABB OVR PV surge protective devices are engineered for photovoltaic power systems, providing coordinated lightning-current and transient overvoltage protection for solar arrays, DC distribution equipment and sensitive inverter electronics.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.