2CTB802402R1000 ABB OVR PV T2 40-1000 C Type 2 PV Surge Protection Cartridge

2CTB802402R1000 ABB OVR PV T2 40-1000 C Type 2 PV Surge Protection Cartridge

ABB OVR PV T2 40-1000 C 2CTB802402R1000 is a pluggable Type 2 replacement surge protection cartridge for 1000 V DC photovoltaic systems with a 40 kA maximum discharge current and 20 kA nominal discharge current.

SKU: 2CTB802402R1000MPN: 2CTB802402R1000
Price
List Price £104.29 ex VAT
Your Price (ex VAT) Save 25%
£78.22 25% OFF
You save £26.07 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £78.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£78.22

Why Choose the ABB OVR PV T2 40-1000 C Replacement Cartridge?

The ABB OVR PV T2 40-1000 C, order code 2CTB802402R1000, is a Type 2 replacement surge protection cartridge designed for compatible ABB OVR PV surge protective devices used in photovoltaic installations. Part of the ABB OVR PV range and ABB's Surge Protection Devices product group, it provides a replaceable protection module for 1000 V DC photovoltaic systems.

The OVR PV T2 40-1000 C is rated for a maximum discharge current (Imax) of 40 kA and a nominal discharge current (In) of 20 kA using an 8/20 µs waveform. Its maximum continuous operating voltage is 1000 V DC, making it suitable for the high DC voltages encountered in modern photovoltaic arrays and associated power distribution equipment.

As a pluggable replacement cartridge, the OVR PV T2 40-1000 C allows the protection module in a compatible ABB OVR PV Type 2 SPD to be replaced while retaining the installed base and wiring. A built-in visual status indicator assists inspection and maintenance, while the compact 17.5 mm width helps minimise space requirements within photovoltaic distribution and protection equipment.

Key Advantages

  • Genuine replacement cartridge for compatible ABB OVR PV Type 2 SPDs.
  • Designed specifically for 1000 V DC photovoltaic applications.
  • 40 kA maximum discharge current (Imax) with an 8/20 µs waveform.
  • 20 kA nominal discharge current (In) for robust transient surge protection.
  • Pluggable construction enables convenient replacement without changing the compatible SPD base.
  • Integrated visual status indicator supports straightforward inspection.

Key Features

  • ABB OVR PV Type 2 surge protection range.
  • OVR PV T2 40-1000 C replacement cartridge.
  • ABB order code 2CTB802402R1000.
  • 1000 V DC nominal voltage.
  • 1000 V DC maximum continuous operating voltage.
  • 40 kA Imax maximum discharge current.
  • 20 kA In nominal discharge current.
  • 8/20 µs discharge current waveform.
  • IP20 protection rating.
  • Visual status indication for convenient maintenance checks.
  • Compact pluggable cartridge designed for photovoltaic surge protection.

Reliable Type 2 Surge Protection for Photovoltaic Systems

Photovoltaic arrays and their associated DC cabling can be exposed to transient overvoltages generated by indirect lightning activity and electrical switching events. Type 2 photovoltaic surge protective devices help limit these transient voltages and divert surge energy away from sensitive equipment such as inverters, monitoring systems and other components within the PV installation.

The OVR PV T2 40-1000 C provides the replaceable protection element for compatible ABB OVR PV Type 2 devices. Its 1000 V DC rating, 40 kA maximum discharge capability and pluggable construction make it a practical maintenance component for photovoltaic surge protection systems where rapid replacement and dependable protection are required.

Typical Applications

  • 1000 V DC photovoltaic installations.
  • Replacement cartridges for compatible ABB OVR PV Type 2 SPDs.
  • Solar PV array DC protection systems.
  • Photovoltaic inverter protection installations.
  • Solar combiner and distribution equipment.
  • Commercial and industrial photovoltaic installations.

Technical Specifications

Tick the specs you need, then view products that match.

SPD Type Type 2
Product Series ABB OVR PV T2
Device Type Replacement cartridge
Series OVR PV
Order code 2CTB802402R1000
Product group Surge Protection Devices
Product type Type 2 replacement surge protection cartridge
Application Photovoltaic DC systems
System configuration DC
Nominal voltage (Un) 1000 V DC
Maximum continuous operating voltage (Uc) 1000 V DC
Maximum discharge current (Imax) 40 kA
Nominal discharge current (In) 20 kA
Discharge current waveform 8/20 µs
Short-circuit current rating (Iscpv) 10,000 A
Voltage protection level (Up) 4 kV
Protection rating IP20
Status indicator Yes
Construction Pluggable replacement cartridge
Standard IEC 61643-31
Maximum operating altitude 2000 m
Dimensions (H × W × D) 57 × 17.5 × 47 mm
Net weight approx. 0.053 kg

Frequently Asked Questions

What is the ABB OVR PV T2 40-1000 C used for?

The ABB OVR PV T2 40-1000 C is a Type 2 replacement surge protection cartridge for compatible ABB OVR PV devices used in 1000 V DC photovoltaic installations.

What is the maximum discharge current of the ABB OVR PV T2 40-1000 C?

The cartridge has a maximum discharge current (Imax) of 40 kA using an 8/20 µs surge current waveform.

What is the nominal discharge current of this cartridge?

The OVR PV T2 40-1000 C has a nominal discharge current (In) of 20 kA.

What DC voltage is the ABB 2CTB802402R1000 designed for?

The cartridge is designed for photovoltaic applications with a nominal and maximum continuous operating voltage of 1000 V DC.

What is the ABB order code for the OVR PV T2 40-1000 C?

The ABB order code for the OVR PV T2 40-1000 C replacement surge protection cartridge is 2CTB802402R1000.

Trusted Photovoltaic Surge Protection from ABB

ABB OVR PV replacement cartridges provide a practical way to maintain compatible photovoltaic Type 2 surge protective devices, combining high DC voltage capability, robust surge current handling and pluggable construction for efficient servicing.