ABB T4V 250 TMA 100-1000 4P Fixed Front Terminals MCCB - 100 A - 1000 V DC (with jumper) - Photovoltaic/DC

ABB T4V 250 TMA 100-1000 4P Fixed Front Terminals MCCB – 100 A – 1000 V DC (with jumper) – Photovoltaic/DC

ABB T4V 250 TMA 100-1000 4P Fixed Front Terminals MCCB – 100 A – 1000 V DC (with jumper) – Photovoltaic/DC (ABB order code 1SDA082617R1).

SKU: 1SDA082617R1MPN: 1SDA082617R1
Price
List Price £1,800.00 ex VAT
Your Price (ex VAT) Save 25%
£1,350.00 25% OFF
You save £450.00 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,350.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,350.00

ABB 1SDA082617R1 T4V 250 TMA 100–1000 A 4-Pole 1000 V DC MCCB

The ABB 1SDA082617R1 is a T4V 250 moulded case circuit breaker designed for high-voltage DC applications, providing dependable overload and short-circuit protection for photovoltaic and DC distribution systems.

This fixed four-pole ABB Tmax T circuit breaker features a 100 A rated current, a 250 A frame size and a TMA thermomagnetic trip unit with an adjustable magnetic release range of 500–1000 A.

Rated for operation at 1000 V DC, the 1SDA082617R1 uses front terminals with a dedicated connection arrangement for 1000 V DC operation and provides a 20 kA ultimate short-circuit breaking capacity at 1000 V DC.

Key Advantages

  • 1000 V DC protection: Designed for high-voltage photovoltaic and DC distribution applications.
  • 100 A rated current: Provides reliable circuit protection for high-voltage DC feeders and equipment.
  • Adjustable magnetic protection: TMA trip unit provides a 500–1000 A magnetic release range.
  • Four-pole configuration: Suitable for multi-pole DC circuit protection and isolation arrangements.
  • Dedicated DC connection arrangement: Configured for 1000 V DC operation using the specified connection jumpers.
  • High short-circuit capability: Provides a 20 kA ultimate short-circuit breaking capacity at 1000 V DC.

Key Features

  • ABB SACE Tmax T4V 250 series
  • 100 A rated current
  • 250 A frame size
  • 1000 V DC rated operating voltage
  • Four-pole construction
  • TMA thermomagnetic trip unit
  • 500–1000 A adjustable magnetic release
  • Fixed installation version
  • Front terminal configuration
  • Connection-jumper arrangement for 1000 V DC operation
  • 20 kA ultimate short-circuit breaking capacity at 1000 V DC
  • 8 kV rated impulse withstand voltage
  • RoHS compliant

Photovoltaic and High-Voltage DC Circuit Protection

The ABB 1SDA082617R1 is intended for high-voltage DC electrical systems where dependable overload and short-circuit protection is required. Its TMA thermomagnetic trip unit combines thermal overload protection with adjustable magnetic protection for fault currents.

The four-pole T4V 250 configuration is specifically listed by ABB for use at 1000 V DC with connection jumpers, making the circuit breaker suitable for photovoltaic installations and other high-voltage DC distribution applications.

Typical Applications

  • Photovoltaic power generation systems
  • PV array and DC distribution protection
  • Solar inverter DC circuits
  • PV combiner and distribution equipment
  • High-voltage DC feeders
  • Renewable energy electrical installations
  • Industrial DC power distribution
  • 1000 V DC circuit overload and short-circuit protection

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 1000 V DC
Supply Type DC
Product Series ABB Tmax T4V
Mounting Type Fixed
Application Power distribution
Trip Unit Thermal-magnetic
Device Type MCCB
Poles 4-pole
Current 100 A
Manufacturer ABB
Part Number 1SDA082617R1
Series SACE Tmax T
Product Family Tmax 1000 V DC
Model T4V 250
Product Type Moulded case circuit breaker
Rated Current 100 A
Frame Rating 250 A
Rated Operating Voltage 1000 V DC
Number of Poles 4
Trip Unit TMA thermomagnetic
Magnetic Release 500–1000 A
Installation Version Fixed
Terminal Arrangement Front terminals
DC Connection Connection jumpers for 1000 V DC operation
Ultimate Short-Circuit Breaking Capacity 20 kA at 1000 V DC
Rated Impulse Withstand Voltage 8 kV
Dimensions (H × W × D) 205 × 140 × 103.5 mm
Mechanical Durability 20,000 cycles
Mechanical Operating Rate 240 cycles/hour
Compliance RoHS
Manufacturer part number 1SDA082617R1
Rated operational voltage 1000 V DC (with jumper)
Version Fixed (F), front terminals (F)

FAQs

What is ABB 1SDA082617R1?

ABB 1SDA082617R1 is a T4V 250 moulded case circuit breaker with a 100 A TMA thermomagnetic trip unit and four-pole configuration for 1000 V DC applications.

What is the rated current of ABB 1SDA082617R1?

The ABB 1SDA082617R1 has a rated current of 100 A and a 250 A frame rating.

What voltage is ABB 1SDA082617R1 designed for?

The 1SDA082617R1 is designed for operation at up to 1000 V DC, making it suitable for high-voltage photovoltaic and DC distribution systems.

What type of trip unit does ABB 1SDA082617R1 use?

The 1SDA082617R1 uses a TMA thermomagnetic trip unit with an adjustable magnetic release range of 500–1000 A.

Does ABB 1SDA082617R1 include the connection jumpers?

The ABB catalogue specifies the 1SDA082617R1 for 1000 V DC use with connection jumpers, but the jumpers are not supplied with the circuit breaker and must be ordered separately using code 1SDA082627R1.

Trusted by

ABB is a globally established manufacturer of electrical distribution and automation technology, with the SACE Tmax range providing circuit protection solutions for industrial, commercial and renewable-energy applications.
{ "@context": "https://schema.org", "@type": "Product", "name": "ABB 1SDA082617R1 T4V 250 TMA 100-1000 4P 1000 V DC", "sku": "1SDA082617R1", "mpn": "1SDA082617R1", "brand": { "@type": "Brand", "name": "ABB" }, "description": "ABB 1SDA082617R1 T4V 250 four-pole moulded case circuit breaker with a 100 A TMA thermomagnetic trip unit for 1000 V DC photovoltaic and high-voltage DC applications.", "category": "Moulded Case Circuit Breaker", "additionalProperty": [ { "@type": "PropertyValue", "name": "Rated Current", "value": "100 A" }, { "@type": "PropertyValue", "name": "Frame Rating", "value": "250 A" }, { "@type": "PropertyValue", "name": "Rated Operating Voltage", "value": "1000 V DC" }, { "@type": "PropertyValue", "name": "Poles", "value": "4" }, { "@type": "PropertyValue", "name": "Trip Unit", "value": "TMA" }, { "@type": "PropertyValue", "name": "Magnetic Release", "value": "500-1000 A" }, { "@type": "PropertyValue", "name": "Short-Circuit Breaking Capacity", "value": "20 kA at 1000 V DC" }, { "@type": "PropertyValue", "name": "Dimensions", "value": "205 x 140 x 103.5 mm" } ] } { "@context": "https://schema.org", "@type": "FAQPage", "mainEntity": [ { "@type": "Question", "name": "What is ABB 1SDA082617R1?", "acceptedAnswer": { "@type": "Answer", "text": "ABB 1SDA082617R1 is a T4V 250 moulded case circuit breaker with a 100 A TMA thermomagnetic trip unit and four-pole configuration for 1000 V DC applications." } }, { "@type": "Question", "name": "What is the rated current of ABB 1SDA082617R1?", "acceptedAnswer": { "@type": "Answer", "text": "The ABB 1SDA082617R1 has a rated current of 100 A and a 250 A frame rating." } }, { "@type": "Question", "name": "What voltage is ABB 1SDA082617R1 designed for?", "acceptedAnswer": { "@type": "Answer", "text": "The 1SDA082617R1 is designed for operation at up to 1000 V DC, making it suitable for high-voltage photovoltaic and DC distribution systems." } }, { "@type": "Question", "name": "What type of trip unit does ABB 1SDA082617R1 use?", "acceptedAnswer": { "@type": "Answer", "text": "The 1SDA082617R1 uses a TMA thermomagnetic trip unit with an adjustable magnetic release range of 500-1000 A." } }, { "@type": "Question", "name": "Does ABB 1SDA082617R1 include the connection jumpers?", "acceptedAnswer": { "@type": "Answer", "text": "The ABB catalogue specifies the 1SDA082617R1 for 1000 V DC use with connection jumpers, but the jumpers are not supplied with the circuit breaker and must be ordered separately using code 1SDA082627R1." } } ] }