ABB T4N/PV-E 250 TMF 200 4P Fixed Front Terminals MCCB - 200 A - 1500 V DC - Photovoltaic/DC

ABB T4N/PV-E 250 TMF 200 4P Fixed Front Terminals MCCB – 200 A – 1500 V DC – Photovoltaic/DC

ABB T4N/PV-E 250 TMF 200 4P Fixed Front Terminals MCCB – 200 A – 1500 V DC – Photovoltaic/DC (ABB order code 1SDA082913R1).

SKU: 1SDA082913R1MPN: 1SDA082913R1
Price
List Price £3,831.51 ex VAT
Your Price (ex VAT) Save 25%
£2,873.63 25% OFF
You save £957.88 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,873.63
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,873.63

ABB 1SDA082913R1 T4N/PV-E 250 TMF 200–2000 A 4-Pole 1500 V DC MCCB

The ABB 1SDA082913R1 is a T4N/PV-E 250 moulded case circuit breaker designed for high-voltage DC applications, providing dependable overload and short-circuit protection for photovoltaic power generation and DC distribution systems.

This fixed four-pole ABB Tmax T circuit breaker features a 250 A rated current and a TMF thermomagnetic trip unit with a 200 A thermal setting and an adjustable magnetic release range of 200–2000 A.

Rated for operation at 1500 V DC, the 1SDA082913R1 has front terminals, a compact 205 × 140 × 103.5 mm construction and an ultimate short-circuit breaking capacity of 7.5 kA at 1500 V DC.

Key Advantages

  • 1500 V DC protection: Designed specifically for high-voltage photovoltaic and DC distribution applications.
  • 250 A rated current: Provides high-capacity circuit protection within the compact T4 frame.
  • TMF thermomagnetic protection: Combines thermal overload protection with adjustable magnetic short-circuit protection.
  • Adjustable magnetic release: Provides a 200–2000 A adjustable magnetic protection range.
  • Four-pole construction: Suitable for multi-pole high-voltage DC circuit protection and isolation arrangements.
  • Fixed front-terminal design: Provides a straightforward installation configuration for DC distribution equipment.

Key Features

  • ABB SACE Tmax T4N/PV-E 250 series
  • 250 A rated uninterrupted current
  • 1500 V DC rated operating voltage
  • Four-pole construction
  • TMF thermomagnetic trip unit
  • 200 A thermal setting
  • 200–2000 A adjustable magnetic release
  • Fixed installation version
  • Front terminal configuration
  • 7.5 kA ultimate short-circuit breaking capacity at 1500 V DC
  • IEC standard
  • RoHS compliant
  • IP20 protection classification

Photovoltaic and 1500 V DC Circuit Protection

The ABB 1SDA082913R1 is designed for photovoltaic installations and other high-voltage DC electrical systems where reliable overload and short-circuit protection is required. Its TMF thermomagnetic release provides thermal protection for sustained overcurrents together with magnetic protection for short-circuit conditions.

As part of the ABB Tmax T-PV-E range, this four-pole 250 A circuit breaker is specifically designed for DC applications up to 1500 V, making it suitable for high-voltage solar generation, DC distribution and renewable-energy installations.

Typical Applications

  • Photovoltaic power generation systems
  • 1500 V DC solar installations
  • PV array and DC distribution protection
  • Solar inverter DC circuits
  • PV combiner and distribution equipment
  • High-voltage DC feeders
  • Renewable energy electrical installations
  • Industrial DC power distribution

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 1500 V DC
Supply Type DC
Product Series ABB Tmax T4N
Mounting Type Fixed
Application Power distribution
Trip Unit Thermal-magnetic
Device Type MCCB
Poles 4-pole
Current 200 A
Manufacturer ABB
Part Number 1SDA082913R1
Series SACE Tmax T
Product Family Tmax T-PV-E
Model T4N/PV-E 250
Product Type Moulded case circuit breaker
Rated Uninterrupted Current 250 A
Rated Operating Voltage 1500 V DC
Number of Poles 4
Trip Unit TMF thermomagnetic
Thermal Setting 200 A
Magnetic Release 200–2000 A
Installation Version Fixed
Terminal Arrangement Front terminals
Ultimate Short-Circuit Breaking Capacity 7.5 kA at 1500 V DC
Reference Standard IEC
Protection Rating IP20
Dimensions (H × W × D) 205 × 140 × 103.5 mm
Weight 3.05 kg
Gross Weight 3.5 kg
Compliance RoHS
Manufacturer part number 1SDA082913R1
Rated operational voltage 1500 V DC
Version Fixed (F), front terminals (F)

FAQs

What is ABB 1SDA082913R1?

ABB 1SDA082913R1 is a T4N/PV-E 250 moulded case circuit breaker with a TMF thermomagnetic trip unit and four-pole configuration for 1500 V DC photovoltaic and high-voltage DC applications.

What is the rated current of ABB 1SDA082913R1?

The ABB 1SDA082913R1 has a rated uninterrupted current of 250 A.

What voltage is ABB 1SDA082913R1 designed for?

The 1SDA082913R1 is rated for operation at up to 1500 V DC, making it suitable for high-voltage photovoltaic and DC distribution systems.

What type of trip unit does ABB 1SDA082913R1 use?

The 1SDA082913R1 uses a TMF thermomagnetic trip unit with a 200 A thermal setting and an adjustable magnetic release range of 200–2000 A.

What is the short-circuit breaking capacity of ABB 1SDA082913R1?

The ABB 1SDA082913R1 has an ultimate short-circuit breaking capacity of 7.5 kA at 1500 V DC.

Trusted by

ABB is a globally established manufacturer of electrical distribution and automation technology, with the SACE Tmax range providing circuit protection solutions for industrial, commercial and renewable-energy applications.
{ "@context": "https://schema.org", "@type": "Product", "name": "ABB 1SDA082913R1 T4N/PV-E 250 TMF 200-2000 4P 1500 V DC", "sku": "1SDA082913R1", "mpn": "1SDA082913R1", "brand": { "@type": "Brand", "name": "ABB" }, "description": "ABB 1SDA082913R1 T4N/PV-E 250 four-pole moulded case circuit breaker with a TMF thermomagnetic trip unit for 1500 V DC photovoltaic and high-voltage DC applications.", "category": "Moulded Case Circuit Breaker", "additionalProperty": [ { "@type": "PropertyValue", "name": "Rated Current", "value": "250 A" }, { "@type": "PropertyValue", "name": "Rated Operating Voltage", "value": "1500 V DC" }, { "@type": "PropertyValue", "name": "Poles", "value": "4" }, { "@type": "PropertyValue", "name": "Trip Unit", "value": "TMF" }, { "@type": "PropertyValue", "name": "Thermal Setting", "value": "200 A" }, { "@type": "PropertyValue", "name": "Magnetic Release", "value": "200-2000 A" }, { "@type": "PropertyValue", "name": "Short-Circuit Breaking Capacity", "value": "7.5 kA at 1500 V DC" }, { "@type": "PropertyValue", "name": "Dimensions", "value": "205 x 140 x 103.5 mm" } ] } { "@context": "https://schema.org", "@type": "FAQPage", "mainEntity": [ { "@type": "Question", "name": "What is ABB 1SDA082913R1?", "acceptedAnswer": { "@type": "Answer", "text": "ABB 1SDA082913R1 is a T4N/PV-E 250 moulded case circuit breaker with a TMF thermomagnetic trip unit and four-pole configuration for 1500 V DC photovoltaic and high-voltage DC applications." } }, { "@type": "Question", "name": "What is the rated current of ABB 1SDA082913R1?", "acceptedAnswer": { "@type": "Answer", "text": "The ABB 1SDA082913R1 has a rated uninterrupted current of 250 A." } }, { "@type": "Question", "name": "What voltage is ABB 1SDA082913R1 designed for?", "acceptedAnswer": { "@type": "Answer", "text": "The 1SDA082913R1 is rated for operation at up to 1500 V DC, making it suitable for high-voltage photovoltaic and DC distribution systems." } }, { "@type": "Question", "name": "What type of trip unit does ABB 1SDA082913R1 use?", "acceptedAnswer": { "@type": "Answer", "text": "The 1SDA082913R1 uses a TMF thermomagnetic trip unit with a 200 A thermal setting and an adjustable magnetic release range of 200-2000 A." } }, { "@type": "Question", "name": "What is the short-circuit breaking capacity of ABB 1SDA082913R1?", "acceptedAnswer": { "@type": "Answer", "text": "The ABB 1SDA082913R1 has an ultimate short-circuit breaking capacity of 7.5 kA at 1500 V DC." } } ] }