Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA104641R1 SACE Emax 2 E6.2H/E9 four-pole withdrawable air circuit breaker with a 6300 A rated uninterrupted current, Ekip Dip LSIG electronic protection and 75 kA short-circuit breaking capacity at 900 V AC.
£47,991.45
The ABB 1SDA104641R1 is a high-capacity SACE Emax 2 air circuit breaker (ACB) engineered for protection and switching in demanding electrical distribution systems operating at 900 V AC. This E6.2H/E9 model combines a 6300 A rated uninterrupted current, four-pole construction and ABB's Ekip Dip LSIG electronic trip unit for comprehensive protection of high-current industrial, infrastructure and energy distribution networks.
The Ekip Dip LSIG electronic protection release provides long-time, short-time, instantaneous and ground-fault protection. These protection functions help safeguard high-current circuits against sustained overloads, short circuits and earth faults while supporting selective coordination with other protective devices throughout the electrical distribution system.
Designed as a withdrawable moving part (WMP) for compatible ABB Emax 2 switchgear, the E6.2H/E9 6300 supports efficient inspection, servicing and replacement. The E6.2H performance level provides a short-circuit breaking capacity of 75 kA at 900 V AC, delivering substantial fault-interruption capability for critical high-power installations.
Air circuit breakers such as the ABB SACE Emax 2 E6.2H/E9 provide switching and protection for high-current electrical distribution systems where substantial prospective fault currents can occur. The Ekip Dip electronic release monitors circuit current and initiates protective operation according to its configured settings, helping safeguard busbars, conductors, switchgear and downstream electrical equipment.
The LSIG protection package combines long-time protection against sustained overloads, short-time protection for selective fault coordination, instantaneous protection against severe short circuits and ground-fault protection for earth-fault conditions. Together with its 6300 A current rating, 75 kA breaking capacity at 900 V AC, four-pole construction and withdrawable Emax 2 architecture, the 1SDA104641R1 provides a robust protection solution for critical high-power distribution switchboards.
Tick the specs you need, then view products that match.
| Voltage | 900 V AC | |
|---|---|---|
| Device Type | ACB | |
| Series | SACE Emax 2 | |
| Order code | 1SDA104641R1 | |
| Product group | Emax 2 Air Circuit Breaker | |
| Product type | Air circuit breaker | |
| Frame | E6.2 | |
| Performance level | H | |
| Rated uninterrupted current (Iu) | 6300 A | |
| Rated system voltage | 900 V AC | |
| Short-circuit breaking capacity at 900 V AC | 75 kA | |
| Number of poles | 4 | |
| Current type | AC | |
| Trip unit | Ekip Dip LSIG | |
| Release type | Electronic | |
| Protection functions | LSIG – long-time, short-time, instantaneous and ground-fault | |
| Long-time overload protection | Yes | |
| Short-time short-circuit protection | Yes | |
| Instantaneous short-circuit protection | Yes | |
| Integrated ground-fault protection | Yes | |
| Execution | Withdrawable moving part (WMP) | |
| Main circuit connection | Connection through separate fixed chassis part | |
| Mounting arrangement | Withdrawable | |
| Application | High-current 900 V AC power distribution | |
| Applicable circuit-breaker standard | EN/IEC 60947-2 |
The ABB 1SDA104641R1 is an Emax 2/E9 air circuit breaker designed for switching and protecting very high-current electrical distribution systems against overload, short-circuit and ground-fault conditions at 900 V AC.
The E6.2H/E9 breaker has a rated uninterrupted current of 6300 A, making it suitable for major industrial, infrastructure and energy distribution loads.
The Ekip Dip LSIG electronic trip unit provides long-time (L), short-time (S), instantaneous (I) and ground-fault (G) protection against sustained overloads, short circuits and earth faults.
The E6.2H/E9 6300 provides a short-circuit breaking capacity of 75 kA at 900 V AC, delivering substantial fault-interruption capability for demanding high-current electrical distribution systems.
Yes. The 1SDA104641R1 is a four-pole withdrawable moving part (WMP) designed for use with a compatible ABB Emax 2 fixed chassis, supporting efficient inspection, servicing and replacement within the switchgear assembly.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection with high short-circuit performance and flexible switchgear integration, providing dependable circuit protection for demanding industrial, infrastructure and energy distribution applications.
We use cookies