1SDA104610R1 ABB E6.2H/E9 6300 Ekip Dip LSI 3P FHR Air Circuit Breaker 900 V

1SDA104610R1 ABB E6.2H/E9 6300 Ekip Dip LSI 3P FHR Air Circuit Breaker 900 V

ABB 1SDA104610R1 is a SACE Emax 2 E6.2H/E9 three-pole fixed air circuit breaker rated at 6300 A and 900 V AC with rear horizontal terminals, an Ekip Dip LSI electronic trip unit and 75 kA ultimate short-circuit breaking capacity at 900 V AC.

SKU: 1SDA104610R1MPN: 1SDA104610R1
Price
List Price £50,610.10 ex VAT
Your Price (ex VAT) Save 25%
£37,957.58 25% OFF
You save £12,652.53 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £37,957.58
Trade pricing is personalised to your account

Manufacturer Lead Time

£37,957.58

Why Choose the ABB 1SDA104610R1 Emax 2 Air Circuit Breaker?

The ABB 1SDA104610R1 is a high-performance E6.2H/E9 6300 Ekip Dip LSI 3-pole air circuit breaker designed for protection and control of very high-current AC power distribution systems operating at 900 V AC. As part of the ABB SACE Emax 2/E9 series, this fixed circuit breaker combines a 6300 A rated uninterrupted current with high short-circuit breaking performance and dependable electronic protection for demanding industrial, infrastructure, utility and power generation applications.

Equipped with the Ekip Dip LSI electronic trip unit, the breaker provides long-time, short-time and instantaneous overcurrent protection. The Ekip Dip platform offers straightforward protection configuration for dependable overload and short-circuit protection, making it well suited to high-capacity installations where robust performance and practical commissioning are required.

The E6.2H/E9 configuration provides a rated uninterrupted current of 6300 A with a rated ultimate short-circuit breaking capacity of 75 kA at 900 V AC. Its three-pole fixed construction with rear horizontal terminals (FHR) is intended for permanent installation in compatible switchboards, providing a robust connection arrangement for very high-current three-phase power distribution.

Key Advantages

  • Very high 6300 A current capacity for large electrical distribution systems.
  • Designed for elevated-voltage applications at 900 V AC.
  • 75 kA ultimate short-circuit breaking capacity at 900 V AC.
  • Dependable Ekip Dip LSI electronic protection trip unit.
  • LSI functionality provides long-time, short-time and instantaneous overcurrent protection.
  • Three-pole configuration for high-current three-phase electrical systems.
  • Fixed construction with rear horizontal terminals for permanent switchboard installation.
  • Part of ABB's SACE Emax 2/E9 platform for demanding high-power distribution applications.

Key Features

  • ABB SACE Emax 2 E6.2H/E9 series.
  • 6300 A rated uninterrupted current.
  • 900 V AC rated voltage.
  • 3-pole circuit breaker configuration.
  • Ekip Dip LSI electronic release.
  • Long-time, short-time and instantaneous overcurrent protection functions.
  • 75 kA Icu at 900 V AC.
  • H short-circuit performance level.
  • Fixed circuit breaker construction.
  • FHR — fixed with rear horizontal terminals.
  • Designed for very high-current power distribution and switchboard applications.

Reliable Circuit Protection for Very High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 provide protection, switching and isolation for high-power electrical distribution networks. The E6.2H/E9 platform is engineered for very high-current applications, and this configuration combines a 6300 A rated uninterrupted current with 75 kA ultimate short-circuit breaking capacity at 900 V AC for demanding power distribution environments.

The integrated Ekip Dip LSI release provides configurable long-time, short-time and instantaneous protection against overload and short-circuit conditions. Combined with its fixed three-pole construction and rear horizontal terminals, the ABB 1SDA104610R1 is well suited to high-capacity switchboards serving industrial plants, utilities, power generation facilities and other critical electrical infrastructure.

Typical Applications

  • Very high-current industrial power distribution systems.
  • Main incoming and electrical distribution switchboards.
  • 900 V AC power distribution applications.
  • Large manufacturing and process plants.
  • Power generation facilities.
  • Utility and energy infrastructure.
  • Renewable energy installations.
  • Large commercial and infrastructure projects.
  • Protection of high-current feeders and critical distribution circuits.
  • Fixed high-capacity switchgear assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 900 V AC
Device Type ACB
Series SACE Emax 2/E9
Order code / SKU 1SDA104610R1
Product type Air circuit breaker
Product group Emax2 Air Circuit Breaker
Frame E6.2
Performance level H
Current type AC
Rated uninterrupted current (Iu) 6300 A
Rated voltage 900 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 900 V AC 75 kA
Number of poles 3P
Release Ekip Dip LSI
Release type Electronic
Protection functions LSI — long-time, short-time and instantaneous
Long-time protection setting range 0.4–1 × In
Short-circuit protection setting range 1–10 × In
Mounting version Fixed
Terminal arrangement FHR — rear horizontal terminals

Frequently Asked Questions

What is the ABB 1SDA104610R1 used for?

The ABB 1SDA104610R1 is an Emax 2/E9 air circuit breaker designed to protect and control very high-current AC power distribution circuits in industrial, infrastructure, utility, power generation and other demanding applications operating at 900 V AC.

What is the current rating of the ABB 1SDA104610R1?

The ABB 1SDA104610R1 has a rated uninterrupted current of 6300 A, making it suitable for very high-current electrical distribution systems.

What does FHR mean on the ABB 1SDA104610R1?

FHR identifies this Emax 2 configuration as a fixed circuit breaker with rear horizontal terminals, providing a permanent switchboard installation with rear-facing horizontal main circuit connections.

What is the breaking capacity of the ABB 1SDA104610R1?

The E6.2H/E9 6300 configuration has a rated ultimate short-circuit breaking capacity (Icu) of 75 kA at 900 V AC.

What protection unit is fitted to the ABB 1SDA104610R1?

The breaker is equipped with an Ekip Dip LSI electronic trip unit, providing long-time, short-time and instantaneous overcurrent protection for dependable high-current power distribution system protection.

Trusted ABB Power Distribution Technology

ABB SACE Emax 2 air circuit breakers are engineered for reliable protection and control of demanding power distribution systems, combining high breaking performance, electronic protection and flexible switchboard integration.