Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA104506R1 Emax 2/E9 E4.2S three-pole withdrawable air circuit breaker with a 4000 A rated current, Ekip Touch LSI electronic protection and 65 kA breaking capacity at 900 V AC.
£21,605.21
The ABB 1SDA104506R1 is a high-performance Emax 2 air circuit breaker (ACB) designed for protection, control and switching in demanding electrical distribution systems operating at 900 V AC. Part of the advanced ABB Emax 2/E9 series, this E4.2S breaker combines a 4000 A rated uninterrupted current, three-pole configuration and Ekip Touch LSI electronic trip unit for dependable protection of high-current industrial and energy distribution networks.
The breaker incorporates ABB's Ekip Touch LSI electronic protection trip unit, providing long-time, short-time and instantaneous overcurrent protection. Its touch-display interface enables convenient access to protection settings and operating information, helping engineers configure and monitor protection within sophisticated electrical distribution systems.
Designed as a withdrawable moving part (WMP) for compatible Emax 2 switchgear, the E4.2S/E9 4000 supports efficient inspection, servicing and replacement. Its S performance level provides an ultimate short-circuit breaking capacity of 65 kA at 900 V AC, making the 1SDA104506R1 well suited to high-current installations requiring robust fault protection and serviceable switchgear architecture.
Air circuit breakers such as the ABB Emax 2/E9 E4.2S are engineered to protect high-current electrical distribution systems against overloads and short circuits. The Ekip Touch electronic trip unit monitors electrical conditions and initiates breaker operation when configured protection thresholds are exceeded, helping protect conductors, switchgear and downstream electrical equipment.
The LSI protection functions provide long-time protection against sustained overloads, short-time protection for selective short-circuit coordination and instantaneous protection against severe fault currents. Combined with the E4.2S/E9's 4000 A current rating, 65 kA breaking capacity at 900 V AC and withdrawable architecture, the 1SDA104506R1 is well suited to critical high-power switchboards where configurable protection, high fault-current capability and serviceability are required.
Tick the specs you need, then view products that match.
| Voltage | 900 V AC | |
|---|---|---|
| Device Type | ACB | |
| Series | Emax 2/E9 | |
| Order code | 1SDA104506R1 | |
| Product type | Air circuit breaker | |
| Frame | E4.2 | |
| Performance level | S | |
| Rated uninterrupted current (Iu) | 4000 A | |
| Rated operational voltage | 900 V AC | |
| Ultimate short-circuit breaking capacity (Icu) at 900 V AC | 65 kA | |
| Number of poles | 3 | |
| Current type | AC | |
| Trip unit | Ekip Touch LSI | |
| Release type | Electronic | |
| Protection functions | LSI – long-time, short-time and instantaneous | |
| Overload protection adjustment range | 1600–4000 A | |
| Short-time short-circuit protection adjustment range | 2400–40000 A | |
| Instantaneous short-circuit protection adjustment range | 6000–60000 A | |
| Ground-fault protection | No integrated G protection | |
| Auxiliary changeover contacts | 4 | |
| Protection rating | IP30 | |
| Execution | Withdrawable moving part (WMP) | |
| Main circuit connection | Connection through separate chassis part | |
| Integrated motor operator | No | |
| Optional motor operator | Yes | |
| Integrated undervoltage release | No | |
| Trip indication | Yes | |
| Product group | Emax 2 Air Circuit Breaker |
The ABB 1SDA104506R1 is an Emax 2/E9 air circuit breaker used for switching and protecting high-current electrical distribution systems against overload and short-circuit conditions at 900 V AC.
The E4.2S/E9 breaker has a rated uninterrupted current of 4000 A, making it suitable for high-current industrial and energy distribution applications.
The Ekip Touch LSI trip unit provides long-time (L), short-time (S) and instantaneous (I) protection against overload and short-circuit conditions.
The E4.2S/E9 4000 has an ultimate short-circuit breaking capacity of 65 kA at 900 V AC, providing robust protection for systems with high prospective fault currents.
Yes. The 1SDA104506R1 is a three-pole withdrawable moving part (WMP) designed for installation in compatible ABB Emax 2 withdrawable switchgear assemblies.
ABB Emax 2 air circuit breakers are engineered for dependable protection and control of demanding electrical distribution systems, combining advanced electronic protection, high short-circuit performance and flexible switchgear integration for industrial, infrastructure and energy applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.