ABB 1SDA104336R1 is a 1250 A four-pole fixed Emax 2 E2.2S/E9 air circuit breaker rated for 900 V AC with an Ekip Touch LSI electronic trip unit, fixed horizontal rear terminals and 50 kA short-circuit breaking capacity.
£7,504.19
The ABB 1SDA104336R1 is a high-performance SACE Emax 2 E2.2S/E9 air circuit breaker designed for protection and switching in demanding low-voltage AC power distribution systems operating at up to 900 V AC. Rated at 1250 A, this four-pole fixed circuit breaker combines ABB's Emax 2 platform with an advanced Ekip Touch LSI electronic trip unit.
The E2.2S/E9 configuration provides a rated ultimate short-circuit breaking capacity of 50 kA at 900 V AC, with the same 50 kA rated service short-circuit breaking capacity. Its Ekip Touch LSI release provides long-time, short-time and instantaneous overcurrent protection for flexible and dependable power distribution system protection.
With a four-pole fixed configuration and fixed horizontal rear (FHR) terminals, the 1SDA104336R1 is designed for integration into compatible switchboards and busbar systems. The combination of a 1250 A current rating, 900 V AC operating capability and ABB electronic protection makes it particularly suitable for demanding industrial, infrastructure and renewable energy applications.
The Ekip Touch LSI electronic trip unit provides long-time, short-time and instantaneous protection functions, enabling the circuit breaker to protect conductors and distribution equipment against overload and short-circuit conditions. Unlike an LSIG release, the LSI configuration does not incorporate integrated earth-fault protection.
Combined with the E2.2S/E9 breaker platform, the trip unit provides advanced electronic protection for systems operating at up to 900 V AC. The breaker's 50 kA short-circuit performance, fixed construction and horizontal rear connections make it well suited to high-capacity switchboards where dependable protection and efficient busbar integration are required.
Tick the specs you need, then view products that match.
| Voltage | 900 V AC | |
|---|---|---|
| Device Type | ACB | |
| Series | SACE Emax 2 | |
| Model / order code | 1SDA104336R1 | |
| Breaker designation | E2.2S/E9 1250 Ekip Touch LSI 4p FHR 900V | |
| Product type | Air circuit breaker | |
| Frame size | E2.2 | |
| Short-circuit performance level | S | |
| Current type | AC | |
| Rated current (In) | 1250 A | |
| Rated uninterrupted current (Iu) | 1250 A | |
| Rated operational voltage (Ue) | 900 V AC | |
| Rated voltage (Ur) | 900 V | |
| Rated insulation voltage (Ui) | 1000 V AC | |
| Rated impulse withstand voltage (Uimp) | 12 kV | |
| Rated ultimate short-circuit breaking capacity (Icu) at 900 V AC | 50 kA | |
| Rated service short-circuit breaking capacity (Ics) at 900 V AC | 50 kA | |
| Rated short-time withstand current (Icw), 1 s | 50 kA | |
| Rated short-time withstand current (Icw), 3 s | 50 kA | |
| Number of poles | 4 | |
| Installation version | Fixed | |
| Terminal configuration | Fixed horizontal rear (FHR) | |
| Trip unit | Ekip Touch LSI | |
| Release type | Electronic | |
| Integrated earth-fault protection | No | |
| Power loss | 83 W | |
| Electrical endurance at 900 V | 2000 cycles | |
| Electrical operating frequency | 30 cycles per hour | |
| Mechanical endurance | 25,000 cycles | |
| Mechanical operating frequency | 60 cycles per hour | |
| Suitable for IT networks | Yes, at 900 V | |
| Standard | IEC | |
| EAN | 8015644064167 |
The ABB 1SDA104336R1 is a 1250 A four-pole fixed Emax 2 air circuit breaker designed for protection and switching in AC power distribution systems operating at up to 900 V AC.
The circuit breaker is fitted with an Ekip Touch LSI electronic trip unit, providing long-time, short-time and instantaneous overcurrent protection.
The 1SDA104336R1 has a rated ultimate short-circuit breaking capacity of 50 kA at 900 V AC and a rated service short-circuit breaking capacity of 50 kA at 900 V AC.
No. The fitted Ekip Touch LSI release provides long-time, short-time and instantaneous protection but does not include integrated earth-fault protection.
The 1SDA104336R1 is a four-pole fixed circuit breaker with fixed horizontal rear (FHR) main terminals for integration with compatible switchboard busbar systems.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, high short-circuit performance and flexible switchboard integration for demanding industrial, infrastructure and renewable energy power distribution applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.