ABB 1SDA104327R1 is a 2500 A three-pole SACE Emax 2 E2.2S/E9 fixed air circuit breaker with horizontal rear terminals, a 900 V AC rating and an Ekip Dip LSI electronic trip unit.
£10,716.08
The ABB 1SDA104327R1 is a SACE Emax 2 E2.2S/E9 air circuit breaker rated at 2500 A and 900 V AC. This three-pole fixed configuration combines the E2.2S frame with an Ekip Dip LSI electronic trip unit and fixed horizontal rear terminals for demanding high-current power distribution applications.
The Ekip Dip LSI electronic release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. The breaker has adjustable overload protection from 1000–2500 A, short-time delayed short-circuit protection from 1500–25000 A and instantaneous short-circuit protection from 3750–37500 A.
The E2.2S/E9 configuration provides a rated ultimate short-circuit breaking capacity of 50 kA at 900 V AC, together with a rated service short-circuit breaking capacity of 50 kA. Its fixed horizontal rear (FHR) main connections are designed for integration into compatible low-voltage switchboards where rear busbar or conductor connections are required.
The Ekip Dip LSI release provides three principal overcurrent protection functions. Long-time protection responds to sustained overload conditions, short-time protection provides a controlled response to high fault currents where coordination with downstream protective devices is required, and instantaneous protection provides rapid interruption of severe short circuits.
Combined with the E2.2S/E9 2500 A breaker platform, 50 kA short-circuit performance at 900 V AC and fixed horizontal rear terminals, these protection functions make the 1SDA104327R1 suitable for high-current switchboards where dependable feeder or incomer protection and rear-connected busbar integration are required.
Tick the specs you need, then view products that match.
| Voltage | 900 V AC | |
|---|---|---|
| Device Type | ACB | |
| Series | SACE Emax 2 | |
| Frame | E2.2S/E9 | |
| ABB order code | 1SDA104327R1 | |
| Product designation | E2.2S/E9 2500 Ekip Dip LSI 3p FHR 900V | |
| Product type | Air circuit breaker | |
| Rated uninterrupted current (Iu) | 2500 A | |
| Rated operational voltage | 900 V AC | |
| Rated insulation voltage (Ui) | 1000 V AC | |
| Number of poles | 3 | |
| Trip unit | Ekip Dip LSI | |
| Protection functions | L, S, I | |
| Overload release adjustment | 1000–2500 A | |
| Short-time delayed short-circuit adjustment | 1500–25000 A | |
| Instantaneous short-circuit adjustment | 3750–37500 A | |
| Rated ultimate short-circuit breaking capacity (Icu) at 900 V AC | 50 kA | |
| Rated service short-circuit breaking capacity (Ics) at 900 V AC | 50 kA | |
| Rated short-time withstand current (Icw), 1 s | 50 kA | |
| Rated short-time withstand current (Icw), 3 s | 50 kA | |
| Earth-fault protection | No | |
| Installation | Fixed | |
| Main terminal arrangement | Horizontal rear | |
| Auxiliary contacts | 4 changeover contacts | |
| Trip indication | Yes | |
| Integrated motor operator | No | |
| Optional motor operator | Yes | |
| Degree of protection | IP30 | |
| Power dissipation | 267 W | |
| EAN | 8015644064075 | |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA104327R1 is an Emax 2 E2.2S/E9 2500 A three-pole fixed air circuit breaker with horizontal rear terminals, a 900 V AC rating and an Ekip Dip LSI electronic trip unit.
The LSI trip unit provides long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I).
The breaker has a rated uninterrupted current of 2500 A, with its overload release adjustable from 1000–2500 A.
The E2.2S/E9 configuration has a rated operational voltage of 900 V AC and a rated insulation voltage of 1000 V AC.
The breaker has a rated ultimate short-circuit breaking capacity Icu of 50 kA at 900 V AC and a rated service short-circuit breaking capacity Ics of 50 kA at 900 V AC.
FHR identifies the breaker as a fixed configuration with horizontal rear terminals, providing rear-facing main-circuit connections for compatible switchboard busbars or conductors.
No. This breaker uses an Ekip Dip LSI release providing L, S and I protection functions. A corresponding LSIG configuration is used when integrated G earth-fault protection is required.
The 1SDA104327R1 is a three-pole air circuit breaker intended for compatible three-phase power distribution systems.
ABB SACE Emax 2 air circuit breakers combine high-current switching, configurable electronic protection and flexible terminal arrangements to provide dependable protection for demanding industrial and infrastructure power distribution systems.