MERSEN FUSE 1200VDC T121 gPV 200A PB DC121GPV12C200P

MERSEN FUSE 1200VDC T121 gPV 200A PB DC121GPV12C200P

Mersen K1025395 DC121GPV12C200P 200 A gPV photovoltaic square-body fuse-link rated at 1200 V DC, with a Size 121 body and plain blade terminals.

SKU: K1025395Alt SKU: DC121GPV12C200PMPN: K1025395
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Mersen K1025395 Photovoltaic Fuse-Link?

The Mersen K1025395, manufacturer reference DC121GPV12C200P, is a high-performance 200 A photovoltaic fuse-link designed to protect cables and electrical equipment within large commercial and utility-scale solar installations. Part of the specialist Mersen HelioProtection® DC120-123 series, it is suitable for photovoltaic circuits operating at up to 1200 V DC.

Photovoltaic arrays can generate sustained reverse currents and low-level DC faults that conventional industrial fuses may not interrupt effectively. The K1025395 features a full-range gPV operating characteristic, enabling it to provide dedicated protection against the particular overcurrent and short-circuit conditions found in solar power systems.

With its Size 121 square-body construction and plain blade terminals, the K1025395 is designed for secure installation within compatible fuse bases and high-current DC assemblies. Its robust construction provides dependable performance during the repeated electrical loading and temperature cycles experienced by photovoltaic installations.

Key Advantages

  • Special-purpose gPV fuse-link for photovoltaic protection.
  • 200 A rated current for high-power solar circuits.
  • 1200 V DC voltage rating for commercial and utility-scale PV systems.
  • Full-range protection against photovoltaic overloads and short circuits.
  • Low fault-current interruption capability for PV-specific operating conditions.
  • Size 121 square-body format for high-current applications.
  • Plain blade terminals support secure installation in compatible fuse equipment.

Key Features

  • Mersen HelioProtection® DC120-123 series.
  • Manufacturer reference: DC121GPV12C200P.
  • Item number: K1025395.
  • 200 A rated current.
  • 1200 V DC rated voltage.
  • Full-range gPV utilisation category.
  • Size 121 square-body fuse-link.
  • Plain blade terminal configuration.
  • Designed to withstand photovoltaic temperature cycles.
  • Suitable for protecting grouped PV string cables.

Reliable Protection for High-Power Photovoltaic Systems

Large photovoltaic arrays require dedicated DC overcurrent protection because their electrical fault behaviour differs from conventional AC distribution systems. A gPV fuse-link is designed to interrupt the complete range of photovoltaic fault currents, including lower-level reverse currents that can remain present for extended periods.

The Mersen K1025395 helps isolate a faulty PV group before excessive current damages cables, modules, connectors or downstream equipment. Its high-current Size 121 construction makes it particularly suitable for combiner assemblies, inverter input circuits and central DC distribution systems.

Typical Applications

  • Utility-scale photovoltaic installations.
  • Commercial solar power systems.
  • Photovoltaic group cable protection.
  • PV combiner and recombiner boxes.
  • Central inverter input protection.
  • High-current DC disconnect assemblies.
  • Renewable energy distribution equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 1200 V
Current 200 A
Device Type Fuse link
Fuse Type PV (gPV)
Fuse Class gPV
Manufacturer Mersen
Brand HelioProtection®
Series DC120-123
Model DC121GPV12C200P
Item number K1025395
EAN 3605340526516
Product type Photovoltaic square-body fuse-link
Application class gPV
Rated current 200 A
Rated voltage 1200 V DC
Fuse size 121
Body construction Square body
Terminal type Plain blade
Mounting type Compatible fuse base or clip mounting
Fuse operation Single use
Approximate weight 1.03 kg
Standards IEC 60269-1 and IEC 60269-6

Frequently Asked Questions

What is the Mersen K1025395 used for?

The K1025395 protects grouped photovoltaic cables and associated DC equipment against reverse currents, overloads and short-circuit faults.

What is the rated current of the K1025395?

The Mersen K1025395 has a rated current of 200 A.

What voltage can this photovoltaic fuse support?

The K1025395 is designed for photovoltaic circuits operating at up to 1200 V DC.

What fuse size is the Mersen K1025395?

This model is a Size 121 square-body fuse-link designed for high-current photovoltaic protection.

What does the gPV classification mean?

The gPV classification indicates that the fuse provides full-range protection against overcurrents and short circuits in photovoltaic circuits.

Trusted by Solar Energy Professionals

Mersen HelioProtection® fuse-links are used by solar engineers, panel builders and renewable energy contractors to provide dependable overcurrent protection for high-voltage photovoltaic installations.