137N5011 Danfoss 315kW iC7-Automation Inverter module

137N5011 Danfoss 315kW iC7-Automation Inverter module

Danfoss 137N5011 iC7-Automation inverter module: 315 kW, 400/460/500 V AC supply, IP00 / Open type.

SKU: 137N5011Alt SKU: IC7-60SAIN05-590AE00F4+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK15+DAAUMPN: 137N5011
Price
List Price £23,912.00 ex VAT
Your Price (ex VAT) Save 25%
£17,934.00 25% OFF
You save £5,978.00 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £17,934.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£17,934.00

Danfoss 137N5011 at a glance

The Danfoss 137N5011 is an iC7-Automation inverter module rated 315 kW for 400/460/500 V AC supplies. It is an IP00 / Open type unit.

The iC7-Automation range is used for industrial automation, machine control and motor-driven process applications. This page lists the ratings that define this exact inverter module; full electrical data, dimensions and installation requirements are in the manufacturer's documentation.

Key ratings

  • Rated output power: 315 kW
  • Supply: 400/460/500 V AC
  • Protection rating: IP00 / Open type
  • Frame size: IM10
  • Typical motor power (light overload): 315KW(400V)/450HP(460V)
  • Continuous current, light overload (IL): 590A(400VAC)/531A(460VAC)
  • Continuous current, high overload (IH): 490A(400VAC)/441A(460VAC)
  • Nominal AC current: 603A(400VAC)/543A(460VAC)
  • Functional safety: None, not upgradable
  • Cooling: Air Cooling
  • Control panel: Control Panel 2.8 OPX20
  • Communication: Modbus TCP OS7MT
  • On-board I/O: 6xDI,2xDO,2xAI,1xAO,thermister input,2xNO/NC,1xNO relays
  • DC-bus voltage: 465-740VDC
  • Brake chopper: No brake chopper
  • PCB coating: Coated PCB
  • Maximum output frequency: 599Hz

Choosing the right size

Size a drive on the motor nameplate current at your actual supply voltage, not on kW alone. Constant-torque loads (conveyors, mixers, hoists, compressors) need the heavy-duty / high-overload rating; variable-torque loads (centrifugal fans and pumps) can use the light-duty rating. If you are unsure, send us the motor nameplate details and the application and we will confirm the right Danfoss drive.

Technical Specifications

Tick the specs you need, then view products that match.

Power 315 kW
Current 590 A
IP Rating IP00
EMC Filter None
Product type Inverter module, INU
Power rating 315 kW/450 HP
Mains voltage 380-500 V AC
Net weight 65 Kilogram
EAN 5715253629025
AC voltage 3X0-400/460/500VAC
check if complete OK
Communication interface, X0 Ethernet port, no protocol
Communication interface, X1/X2 Modbus TCP OS7MT
Continous current IH (1/5min) 490A(400VAC)/441A(460VAC)
Continous current IL (1/5min) 590A(400VAC)/531A(460VAC)
Control panel Control Panel 2.8 OPX20
Control panel cable length 1.5 m (5 ft)
Control panel mounting type Flush mount
Control unit cable length 1.5 m (5 ft), Fiber
Cooling circuit connector type Not relevant
Cooling circuit hose length Not relevant
Cooling type Air Cooled
Current rating 590 A
Customer specific application None
Customer-specific label None
Customization file package ID No customization
DC Bus current 641A(540VDC)
DC Bus voltage 465-740VDC
DC fuses and devices None
DC power 346kW(540VDC)
Documentation language Multi-language
EMC category C4 category
Enclosure rating IP00 / OPEN TYPE
Extra environmental protection Coated boards
Frame designation IM10
Functional safety None, not upgradable
Gross weight 80 Kilogram
Help Counter 1
High speed enabled No
Integration unit None
Language package Global
Main unit Depth 502MM/19.8IN
Main unit Height 990MM/39IN
Main unit Width 170MM/6.7IN
Mains input device None
Marine construction None
Modelcode01 IC7-60SAIN05-590AE00F4
Modelcode03 +BAMT+BDC1+BEXX+BF20
Modelcode04 +BGK1+BH15+BK15
Modelcode06 +DAAU
Nominal AC current 603A(400VAC)/543A(460VAC)
Option slot A None, without mounting p
Option slot B None, without mounting plate
Option slot C None, without mounting plate
Option slot D None, without mounting plate
Option slot E None, without mounting plate
Option slot F None, without mounting plate
Option slot G None, without mounting plate
Option slot H None, without mounting plate
Option slot I None, without mounting plate
Option slot J None, without mounting plate
Output frequency 0-590Hz
Overload current IH (1/5min) 735A(400VAC)/662A(460VAC)
Overload current IL (1/5min) 649A(400VAC)/585A(460VAC)
Product category System module, air-cooled
Product Category -DrivesSymbol System module, air-cooled
Product group iC7-60
Product series iC7-Automation
Product software ID Latest released version
Product specific marine cert. None
Product Type - DrivesSymbol Inverter module
Protection rating IP00/Open Type
Salescode part 1 IC7-60SAIN05-590AE00F4
Salescode part 2 +BAMT+BDC1+BEXX+BF20
Salescode part 3 +BGK1+BH15+BK15
Salescode part 4 +DAAU
Shipping package Cardboard box package
Short circuit current rating 100kA
Standard I/O I/O and Relay Option OC7C1
StarCoupler board cable length None
Start current Imax (3sec) 833A
Storage temperature -40...70°C/-40...158°F
Technical documentation None
Typecode Part 1 7SM-AUSAIN05-590AE00F4
Typecode Part 2 -000134650
Typical motor power PH2 (150%) 250kW(400VAC)/350Hp(460VAC)
Typical motor power PL (110%) 315kW(400VAC)/450Hp(460VAC)

Frequently asked questions

What motor power is the 137N5011 rated for?

315 kW.

What supply voltage does it need?

400/460/500 V AC.

Does it need to go inside a control panel?

Yes. It is rated IP00 / Open type, so it is designed to be mounted inside an enclosure or control panel.

What is the full Danfoss type code?

IC7-60SAIN05-590AE00F4+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK15+DAAU.