135X5642 Danfoss VLT HVAC Drive 7.5 kW/10HP 525-600VAC IP66

135X5642 Danfoss VLT HVAC Drive 7.5 kW/10HP 525-600VAC IP66

Danfoss 135X5642 VLT HVAC Drive FC 102 variable speed drive, 7.5 kW / 10 HP, three-phase 525-600 V AC, IP66 / NEMA 4X enclosure, with BACnet/IP MCA 125 and MCB-114 VLT Sensor Input options for HVAC motor control applications.

SKU: 135X5642Alt SKU: FC-102P7K5T6E66HXBGXXOXSXXXXAKB4CXXXXDXMPN: 135X5642
Price
List Price £2,476.00 ex VAT
Your Price (ex VAT) Save 45%
£1,361.80 45% OFF
You save £1,114.20 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,361.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,361.80

Danfoss 135X5642 at a glance

The Danfoss 135X5642 is a 7.5 kW VLT HVAC Drive FC 102 for 3 × 525–600 V AC supplies, made for the fans, pumps and compressors in building services. It is an IP66 / UL Type 4X unit, built for wall mounting in wet, dusty or wash-down locations.

This configuration has no RFI filter, brake chopper, a graphical LCP 102 control panel, and a BACnet/IP MCA 125 fieldbus card. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Enclosure: IP66 / UL Type 4X — built for wall mounting in wet, dusty or wash-down locations.
  • EMC: No RFI filter. Check the permitted screened motor cable length in the Danfoss FC 102 Design Guide.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same 7.5 kW rating, other enclosures

This driveIP66Danfoss 135X5642IP66 / UL Type 4X
EnclosureIP55Danfoss 131F8347IP55 / UL Type 12 with backplateView drive →

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 7.5 kW
Voltage 600 V
Phase Three Phase
IP Rating IP66
EMC Filter None
Series VLT® HVAC Drive FC 102
Part Number 135X5642
Model Code FC-102P7K5T6E66HXBGXXOXSXXXXAKB4CXXXXDX
Product type Variable speed drive / frequency converter
Rated output power 7.5 kW
Horsepower rating 10 HP
Input voltage 525-600 V AC
Input phases Three-phase
Frequency 50 / 60 Hz
Protection rating IP66 / NEMA 4X
RFI filter No RFI filter
Brake chopper Included
PCB type Not coated PCB
A option MCA 125 BACnet/IP
B option MCB-114 VLT Sensor Input
Adaptation A Metric thread cable entry
Dimensions (H × W × D) approx. 420 × 242 × 200 mm
Net weight approx. 12.58 kg
EAN 5710108419530

Frequently asked questions

Which communication protocols does it support?

This unit is fitted with a BACnet/IP MCA 125 card, in addition to the built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee.

Can this drive be wall mounted without a panel?

Yes. The IP66 / UL Type 4X enclosure is designed for direct mounting.

Type code decoded

FC-102P7K5T6E66HXBGXXOXSXXXXAKB4CXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
7.5 kWP7K5
Mains voltage
Position 11–12
3 × 525–600 V ACT6
Enclosure
Position 13–15
IP66 / UL Type 4XE66
RFI filter
Position 16–17
No RFI filterHX
Brake / Safe Stop
Position 18
Brake chopperB
Local control panel
Position 19
Graphical LCP 102G
PCB coating
Position 20
Standard (uncoated) PCBsX
Mains option
Position 21
No mains optionX
Adaptation A
Position 22
Metric cable entriesO
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
BACnet/IP MCA 125AK
B option (I/O)
Position 31–32
Refer to the Danfoss FC 102 type-code guideB4
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX