135N8950 Danfoss VLT HVAC Drive 1.1 kW/1.5HP 380-480VAC IP66

135N8950 Danfoss VLT HVAC Drive 1.1 kW/1.5HP 380-480VAC IP66

Danfoss 135N8950 VLT HVAC Drive FC 102, a 1.1 kW three-phase AC variable speed drive designed for HVAC pumps, fans, compressors and building services applications with IP66 protection.

SKU: 135N8950Alt SKU: FC-102P1K1T4E66H3XXXXOXSXXXXAXBXCXXXXDXMPN: 135N8950
Price
List Price £921.00 ex VAT
Your Price (ex VAT) Save 45%
£506.55 45% OFF
You save £414.45 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £506.55
Trade pricing is personalised to your account

Manufacturer Lead Time

£506.55

Danfoss 135N8950 at a glance

The Danfoss 135N8950 is a 1.1 kW / 1.5 HP VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame A5, IP66 / UL Type 4X unit, built for wall mounting in wet, dusty or wash-down locations.

This configuration has RFI class A1/B (C1) with reduced motor cable length, no brake chopper, and no local control panel. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Enclosure: IP66 / UL Type 4X — built for wall mounting in wet, dusty or wash-down locations.
  • EMC: RFI class A1/B (C1) is met only with a reduced screened motor cable length. Check the maximum length for this frame in the Danfoss FC 102 Design Guide (Technical Documents tab); for longer runs, ask us about an H2 (A2/C3) variant.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same configuration, different power

This drive1.1 kWDanfoss 135N8950IP66 / UL Type 4X · frame A5
Larger1.5 kWDanfoss 135N8951IP66 / UL Type 4X · frame A5View drive →

Same 1.1 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 1.1 kW
Voltage 480 V
Phase Three Phase
IP Rating IP66
EMC Filter Commercial
Series VLT HVAC Drive FC 102
Part number 135N8950
Model code FC-102P1K1T4E66H3XXXXOXSXXXXAXBXCXXXXDX
Product type AC variable speed drive
Rated output power 1.1 kW / 1.5 HP
Input voltage 380–480 V AC
Input phases Three phase
Output phases Three phase
Protection rating IP66 / NEMA 4X
RFI filter Class A1/B (C1)
Brake chopper No
A option No A option
B option No B option
Control panel No Local Control Panel
PCB protection Not coated PCB
Mains option No mains option
Adaptation A Metric thread cable entry
Frame size A5
Dimensions (H × W × D) approx. 420 × 242 × 200 mm
Weight approx. 11.3 kg
EAN 5710108251697

Frequently asked questions

What is the maximum motor cable length with this RFI filter?

The 135N8950 has the H3 filter: RFI class A1/B (C1) with a reduced motor cable length. The exact limit for this frame is in the Danfoss VLT HVAC Drive FC 102 Design Guide (see Technical Documents). If your screened cable run is longer, contact us and we will suggest an alternative.

Which communication protocols are built in?

Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee over the built-in RS-485 port. This unit has no fieldbus option card fitted, so PROFIBUS, PROFINET, EtherNet/IP or BACnet/IP would need an MCA option card.

Can this drive be wall mounted without a panel?

Yes. The IP66 / UL Type 4X enclosure is designed for direct mounting.

Type code decoded

FC-102P1K1T4E66H3XXXXOXSXXXXAXBXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
1.1 kW / 1.5 HPP1K1
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP66 / UL Type 4XE66
RFI filter
Position 16–17
RFI class A1/B (C1) with reduced motor cable lengthH3
Brake / Safe Stop
Position 18
No brake chopperX
Local control panel
Position 19
No local control panelX
PCB coating
Position 20
Standard (uncoated) PCBsX
Mains option
Position 21
No mains optionX
Adaptation A
Position 22
Metric cable entriesO
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
No fieldbus optionAX
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX