134U7013 Danfoss VLT HVAC Drive 30 kW/40HP 380-480VAC IP21

134U7013 Danfoss VLT HVAC Drive 30 kW/40HP 380-480VAC IP21

Danfoss 134U7013 VLT HVAC Drive FC 102, a 30 kW three-phase variable frequency drive with IP21 / Type 1 enclosure, BACnet MCA 109 and mains disconnect for HVAC motor control, pumps, fans and compressors.

SKU: 134U7013Alt SKU: FC-102P30KT4E21H3XGX1XXSXXXXAJBXCXXXXDXMPN: 134U7013
Price
List Price £4,431.00 ex VAT
Your Price (ex VAT) Save 45%
£2,437.05 45% OFF
You save £1,993.95 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,437.05
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,437.05

Danfoss 134U7013 at a glance

The Danfoss 134U7013 is a 30 kW VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame B2, IP21 / UL Type 1 unit, suitable for mounting in clean, dry indoor plant rooms.

This configuration has RFI class A1/B (C1) with reduced motor cable length, no brake chopper, a graphical LCP 102 control panel, and a BACnet MCA 109 fieldbus card. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Enclosure: IP21 / UL Type 1 — suitable for mounting in clean, dry indoor plant rooms.
  • EMC: RFI class A1/B (C1) is met only with a reduced screened motor cable length. Check the maximum length for this frame in the Danfoss FC 102 Design Guide (Technical Documents tab); for longer runs, ask us about an H2 (A2/C3) variant.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same configuration, different power

This drive30 kWDanfoss 134U7013IP21 / UL Type 1 · frame B2
Larger55 kWDanfoss 134U7012IP21 / UL Type 1 · frame C1View drive →

Same 30 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 30 kW
Voltage 480 V
Phase Three Phase
IP Rating IP21
EMC Filter Commercial
Series VLT® HVAC Drive FC 102
Type code FC-102P30KT4E21H3XGX1XXSXXXXAJBXCXXXXDX
Product type Variable frequency drive
Rated output power 30 kW
Horsepower rating 40 HP
Input voltage 380–480 V AC
Input phases Three-phase
Output phases Three-phase
Application HVAC motor control
Protection rating IP21 / Type 1
RFI filter Class A1/B (C1)
Brake chopper Not fitted
A option BACnet MCA 109
B option No B option
Local control panel Graphical LCP
PCB coating Not coated PCB
Mains option Mains disconnect
Frame size B2
Dimensions (H × W × D) approx. 650 × 242 × 260 mm
Barcode 5710108030476

Frequently asked questions

What is the maximum motor cable length with this RFI filter?

The 134U7013 has the H3 filter: RFI class A1/B (C1) with a reduced motor cable length. The exact limit for this frame is in the Danfoss VLT HVAC Drive FC 102 Design Guide (see Technical Documents). If your screened cable run is longer, contact us and we will suggest an alternative.

Which communication protocols does it support?

This unit is fitted with a BACnet MCA 109 card, in addition to the built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee.

Can this drive be wall mounted without a panel?

Yes. The IP21 / UL Type 1 enclosure is designed for direct mounting.

Type code decoded

FC-102P30KT4E21H3XGX1XXSXXXXAJBXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
30 kWP30K
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP21 / UL Type 1E21
RFI filter
Position 16–17
RFI class A1/B (C1) with reduced motor cable lengthH3
Brake / Safe Stop
Position 18
No brake chopperX
Local control panel
Position 19
Graphical LCP 102G
PCB coating
Position 20
Standard (uncoated) PCBsX
Mains option
Position 21
Mains disconnect1
Adaptation A
Position 22
Standard cable entriesX
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
BACnet MCA 109AJ
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX