134U3550 Danfoss VLT AQUA Drive FC 200 15 KW / 20 HP, 380 - 480 VAC, IP55

134U3550 Danfoss VLT AQUA Drive FC 200 15 KW / 20 HP, 380 – 480 VAC, IP55

Danfoss 134U3550 VLT AQUA Drive FC 202 variable frequency drive, 15 kW, 20 HP, three phase 380–480 V AC, IP55 / Type 12 B1 frame drive with RFI Class A1/B filtering, mains disconnect and MCB 109 I/O for water, wastewater and industrial pump control applications.

SKU: 134U3550Alt SKU: FC-202P15KT4P55H3XGX1XXSXXXXAXB0CXXXXDXMPN: 134U3550
Price
List Price £3,167.00 ex VAT
Your Price (ex VAT) Save 25%
£2,375.25 25% OFF
You save £791.75 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,375.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,375.25

Why Choose the Danfoss 134U3550 VLT® AQUA Drive FC 202?

The Danfoss 134U3550 is a reliable and efficient AC variable frequency drive (VFD) from the Danfoss VLT® AQUA Drive FC 202 series, designed for precise motor control in water, wastewater and industrial fluid handling applications. Built for pump and fan systems, this drive helps optimise performance, reduce energy consumption and support dependable process operation.

The VLT AQUA Drive FC 202 range is purpose-built for AC-motor-driven water and wastewater systems, offering intelligent pump control, advanced protection features and flexible installation options. Its dedicated water application functionality helps reduce mechanical stress, minimise water hammer and improve overall system efficiency.

With a rated output power of 15 kW and a three-phase 380–480 V AC supply, the Danfoss 134U3550 is suitable for pumps, fans, blowers and process motors. The IP55 / Type 12 backplate-mounted enclosure provides enhanced protection for installations where greater ingress protection and robust construction are required.

Key Advantages

  • Dedicated variable frequency drive for water and wastewater applications.
  • 15 kW / 20 HP motor power rating for pump and fan control.
  • Three-phase 380–480 V AC input compatible with industrial electrical supplies.
  • IP55 / Type 12 enclosure for protected installation environments.
  • RFI Class A1/B (C1) filter for improved EMC performance.
  • Mains disconnect included for practical isolation and maintenance.
  • MCB 109 I/O with RTC back-up option for expanded control functionality.

Key Features

  • Danfoss VLT® AQUA Drive FC 202 series.
  • 15 kW rated output power.
  • 20 HP motor rating.
  • Three-phase 380–480 V AC input supply.
  • IP55 / Type 12 B1 frame enclosure.
  • RFI Class A1/B (C1) filtering.
  • No brake chopper configuration.
  • Graphical local control panel included.
  • Not coated PCB configuration.
  • Mains disconnect included.
  • MCB 109 I/O with real-time clock back-up.

Efficient Motor Control for Water Systems

Variable frequency drives such as the Danfoss VLT® AQUA Drive FC 202 regulate motor speed by adjusting output frequency and voltage. This allows pumps, fans and process motors to operate according to real system demand, reducing wasted energy while improving flow, pressure and process stability.

The Danfoss 134U3550 is particularly suited to water and wastewater systems where dependable motor control, protected installation and practical maintenance access are essential. Its IP55 enclosure, RFI filtering, mains disconnect and MCB 109 I/O option make it a strong choice for modern fluid handling and industrial automation applications.

Typical Applications

  • Water treatment systems.
  • Wastewater processing facilities.
  • Booster pump stations.
  • Industrial pumping systems.
  • Irrigation and water distribution networks.
  • Fans, blowers and ventilation equipment.
  • Fluid handling and process automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Power 15 kW
Voltage 480 V
Phase Three Phase
IP Rating IP55
EMC Filter Commercial
Series VLT® AQUA Drive FC 202
Alternative model code FC-202P15KT4P55H3XGX1XXSXXXXAXB0CXXXXDX
Product type AC variable frequency drive
Rated output power 15 kW
Horsepower 20 HP
Input voltage 380–480 V AC
Input phases 3-phase
Frequency 50 / 60 Hz
Protection rating IP55 / Type 12
Mounting type Backplate / wall mounting
RFI filter Class A1/B (C1)
Brake chopper No brake chopper
Control panel Graphical local control panel
PCB coating Not coated PCB
Mains option Mains disconnect
Option card MCB 109 I/O with RTC back-up
Frame size B1

Frequently Asked Questions

What is the Danfoss 134U3550 used for?

The Danfoss 134U3550 is used to control AC motor speed in water, wastewater, pumping, fan and industrial fluid handling applications.

What motor power is supported by this drive?

The drive supports motors with a rated output power of approximately 15 kW or 20 HP.

What supply voltage does the drive require?

The 134U3550 operates from a three-phase 380–480 V AC supply.

What enclosure rating does this drive have?

This drive has an IP55 / Type 12 enclosure, making it suitable for protected installation environments where greater ingress protection is required.

Does this drive include a brake chopper?

No, this configuration is supplied with no brake chopper.

Trusted by Water Industry Professionals Worldwide

Danfoss VLT® AQUA Drive FC 202 variable frequency drives are widely trusted by engineers and operators for efficient pump control, reliable performance and integration into water, wastewater and industrial automation systems.