134F6652 Danfoss VLT FC-102 HVAC Drive 5.5 kW / 7.5 HP, 380 - 480 VAC, IP55

134F6652 Danfoss VLT FC-102 HVAC Drive 5.5 kW / 7.5 HP, 380 – 480 VAC, IP55

Danfoss 134F6652 VLT HVAC Drive FC-102, a 5.5 kW / 7.5 HP three phase 380-480 V AC variable frequency drive with IP55 / Type 12 backplate enclosure, RFI Class A1/B filter, numerical local control panel, no brake chopper and no mains option for HVAC motor control applications.

SKU: 134F6652Alt SKU: FC-102P5K5T4P55H3XNXXOXSXXXXAXBXCXXXXDXMPN: 134F6652
Price
List Price £1,564.00 ex VAT
Your Price (ex VAT) Save 45%
£860.20 45% OFF
You save £703.80 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £860.20
Trade pricing is personalised to your account

Manufacturer Lead Time

£860.20

Danfoss 134F6652 at a glance

The Danfoss 134F6652 is a 5.5 kW / 7.5 HP VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame A5, IP55 / UL Type 12 with backplate unit, built for wall mounting in plant rooms without a separate enclosure.

This configuration has RFI class A1/B (C1) with reduced motor cable length, no brake chopper, and a numeric LCP 101 control panel. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Continuous output current: 13 A. Size the drive on the motor nameplate current at your actual supply voltage.
  • Intermittent (overload) current: 14.3 A — the normal-overload rating that suits variable-torque fan and pump loads.
  • Enclosure: IP55 / UL Type 12 with backplate — built for wall mounting in plant rooms without a separate enclosure.
  • EMC: RFI class A1/B (C1) is met only with a reduced screened motor cable length. Check the maximum length for this frame in the Danfoss FC 102 Design Guide (Technical Documents tab); for longer runs, ask us about an H2 (A2/C3) variant.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same configuration, different power

This drive5.5 kWDanfoss 134F6652IP55 / UL Type 12 with backplate · frame A5
Larger7.5 kWDanfoss 134F6653IP55 / UL Type 12 with backplate · frame A5View drive →

Same 5.5 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 5.5 kW
Voltage 480 V
Phase Three Phase
IP Rating IP55
EMC Filter Commercial
Series VLT® HVAC Drive FC-102
Model / type code FC-102P5K5T4P55H3XNXXOXSXXXXAXBXCXXXXDX
Product code / SKU 134F6652
Product type HVAC variable frequency drive / frequency converter
Rated output power 5.5 kW / 7.5 HP
Supply voltage 380-480 V AC
Input phases Three phase
Apparent power 9.01 kVA
Continuous current 13 A
Intermittent current 14.3 A
Power loss 187 W
Enclosure rating IP55 / Type 12 backplate
RFI filter Class A1/B (C1)
Brake option No brake chopper
Control panel Numerical local control panel
PCB coating Not coated PCB
Mains option No mains option
Adaptation A Metric thread cable entry
Adaptation B No adaptation
A option No A option
B option No B option
C0 option No C0 option
C1 option No C1 option
C option software No software option
D option No D option
Software release Latest release standard software
Frame size A5
Dimensions (H × W × D) approx. 420 × 242 × 200 mm
Depth with option A/B approx. 200 mm
Net weight approx. 13.07 kg
Gross weight approx. 13.686 kg
Volume 39.798 litres
EAN 5710107468973

Frequently asked questions

What is the maximum motor cable length with this RFI filter?

The 134F6652 has the H3 filter: RFI class A1/B (C1) with a reduced motor cable length. The exact limit for this frame is in the Danfoss VLT HVAC Drive FC 102 Design Guide (see Technical Documents). If your screened cable run is longer, contact us and we will suggest an alternative.

Which communication protocols are built in?

Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee over the built-in RS-485 port. This unit has no fieldbus option card fitted, so PROFIBUS, PROFINET, EtherNet/IP or BACnet/IP would need an MCA option card.

What output current does it deliver at 400 V and at 480 V?

Continuous output current is 13 A; intermittent current is 14.3 A. Always size on the motor nameplate current at your supply voltage.

Can this drive be wall mounted without a panel?

Yes. The IP55 / UL Type 12 with backplate enclosure is designed for direct mounting.

Type code decoded

FC-102P5K5T4P55H3XNXXOXSXXXXAXBXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
5.5 kW / 7.5 HPP5K5
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP55 / UL Type 12 with backplateP55
RFI filter
Position 16–17
RFI class A1/B (C1) with reduced motor cable lengthH3
Brake / Safe Stop
Position 18
No brake chopperX
Local control panel
Position 19
Numeric LCP 101N
PCB coating
Position 20
Standard (uncoated) PCBsX
Mains option
Position 21
No mains optionX
Adaptation A
Position 22
Metric cable entriesO
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
No fieldbus optionAX
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX