131Z9003 Danfoss VLT FC-102 HVAC Drive 800 kW, 380 - 480 VAC, IP54

131Z9003 Danfoss VLT FC-102 HVAC Drive 800 kW, 380 – 480 VAC, IP54

Danfoss 131Z9003 VLT HVAC Drive FC-102 frequency converter, 800 kW / 1200 HP, three phase 380-480 V AC, IP54 / Type 12, RFI Class A2 filter, brake chopper, graphical local control panel and coated PCB, designed for high-power HVAC motor control in ventilation, heating, refrigeration and air handling applications.

SKU: 131Z9003Alt SKU: FC-102P800T4E54H2BGCXXXSXXXXAXBXCXXXXDXMPN: 131Z9003
Price
List Price £123,567.00 ex VAT
Your Price (ex VAT) Save 45%
£67,961.85 45% OFF
You save £55,605.15 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £67,961.85
Trade pricing is personalised to your account

Manufacturer Lead Time

£67,961.85

Danfoss 131Z9003 at a glance

The Danfoss 131Z9003 is an 800 kW VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame F2, IP54 / UL Type 12 unit, built for wall mounting in plant rooms without a separate enclosure.

This configuration has RFI class A2 (C3), brake chopper, and a graphical LCP 102 control panel. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Continuous output current: 1460 A / 1380 A. Size the drive on the motor nameplate current at your actual supply voltage.
  • Intermittent (overload) current: 1606 A / 1518 A — the normal-overload rating that suits variable-torque fan and pump loads.
  • Enclosure: IP54 / UL Type 12 — built for wall mounting in plant rooms without a separate enclosure.
  • EMC: RFI class A2 (C3). Check the permitted screened motor cable length in the Danfoss FC 102 Design Guide.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 800 kW
Voltage 480 V
Phase Three Phase
IP Rating IP54
EMC Filter Industrial
Series VLT® HVAC Drive FC-102
Product code 131Z9003
Model code FC-102P800T4E54H2BGCXXXSXXXXAXBXCXXXXDX
Product type Frequency converter / variable speed drive
Application type HVAC drive
Rated power 800 kW / 1200 HP
Input voltage 380-480 V AC
Input phases Three phase
Enclosure rating IP54 / Type 12
RFI filter Class A2 (C3)
Frame size F2
Control panel Graphical local control panel
Brake chopper Brake chopper included
PCB coating Coated PCB
Mains option No mains option
Adaptation A Standard cable entries
Adaptation B No adaptation
A option No A option
B option No B option
C0 option No C0 option
C1 option No C1 option
Software option No software option
D option No D option
Software release Latest release standard software
Language pack Standard language pack
Continuous current 1460 A / 1380 A
Intermittent current 1606 A / 1518 A
kVA rating 1012 kVA
Power loss 17293 W / 16229 W
Dimensions (H × W × D) 2204 × 1800 × 606 mm
Gross weight 1037.3 kg
Net weight 1037 kg
Volume 6569.742 L
EAN 5710107386994

Frequently asked questions

Which communication protocols are built in?

Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee over the built-in RS-485 port. This unit has no fieldbus option card fitted, so PROFIBUS, PROFINET, EtherNet/IP or BACnet/IP would need an MCA option card.

What output current does it deliver at 400 V and at 480 V?

Continuous output current is 1460 A / 1380 A; intermittent current is 1606 A / 1518 A. Always size on the motor nameplate current at your supply voltage.

Can this drive be wall mounted without a panel?

Yes. The IP54 / UL Type 12 enclosure is designed for direct mounting.

Type code decoded

FC-102P800T4E54H2BGCXXXSXXXXAXBXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
800 kWP800
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP54 / UL Type 12E54
RFI filter
Position 16–17
RFI class A2 (C3)H2
Brake / Safe Stop
Position 18
Brake chopperB
Local control panel
Position 19
Graphical LCP 102G
PCB coating
Position 20
Conformal-coated PCBsC
Mains option
Position 21
No mains optionX
Adaptation A
Position 22
Standard cable entriesX
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
No fieldbus optionAX
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX