131Z2208 Danfoss VLT FC-102 HVAC Drive 1.1 kW / 1.5 HP, 380 - 480 VAC, IP66

131Z2208 Danfoss VLT FC-102 HVAC Drive 1.1 kW / 1.5 HP, 380 – 480 VAC, IP66

Danfoss 131Z2208 VLT HVAC Drive FC-102 frequency converter, 1.1 kW / 1.5 HP, three phase 380-480 V AC, IP66 / Type 4X, designed for HVAC motor control in ventilation, heating and air handling applications.

SKU: 131Z2208Alt SKU: FC-102P1K1T4Z66H1XGXXOXSXXXXAXBXCXXXXDXMPN: 131Z2208
Price
List Price £1,007.00 ex VAT
Your Price (ex VAT) Save 45%
£553.85 45% OFF
You save £453.15 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £553.85
Trade pricing is personalised to your account

Manufacturer Lead Time

£553.85

Danfoss 131Z2208 at a glance

The Danfoss 131Z2208 is a 1.1 kW / 1.5 HP VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame A4, IP66 / UL Type 4X, A4 frame unit, built for wall mounting in wet, dusty or wash-down locations.

This configuration has RFI class A1/B (C1), no brake chopper, and a graphical LCP 102 control panel. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Continuous output current: 3 A / 2.7 A. Size the drive on the motor nameplate current at your actual supply voltage.
  • Intermittent (overload) current: 3.3 A / 2.97 A — the normal-overload rating that suits variable-torque fan and pump loads.
  • Enclosure: IP66 / UL Type 4X, A4 frame — built for wall mounting in wet, dusty or wash-down locations.
  • EMC: RFI class A1/B (C1). Check the permitted screened motor cable length in the Danfoss FC 102 Design Guide.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same configuration, different power

This drive1.1 kWDanfoss 131Z2208IP66 / UL Type 4X, A4 frame · frame A4
Larger1.5 kWDanfoss 131X8902IP66 / UL Type 4X, A4 frame · frame A4View drive →

Same 1.1 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 1.1 kW
Voltage 480 V
Phase Three Phase
IP Rating IP66
EMC Filter Commercial
Series VLT® HVAC Drive FC-102
Product code 131Z2208
Model code FC-102P1K1T4Z66H1XGXXOXSXXXXAXBXCXXXXDX
Product type Frequency converter / variable speed drive
Application type HVAC drive
Rated power 1.1 kW / 1.5 HP
Input voltage 380-480 V AC
Input phases Three phase
Enclosure rating IP66 / Type 4X
RFI filter Class A1/B (C1)
Frame size A4
Control panel Graphical local control panel
Brake chopper No brake chopper
PCB coating Not coated PCB
Mains option No mains option
Adaptation A Metric thread cable entry
Adaptation B No adaptation
Software release Latest release standard software
Language pack Standard language pack
Continuous current 3 A / 2.7 A
Intermittent current 3.3 A / 2.97 A
kVA rating 2.08 kVA
Power loss 58 W
Dimensions (H × W × D) 391 × 200 × 177 mm
Gross weight 8.476 kg
Net weight 7.74 kg
Volume 47.293 L

Frequently asked questions

Which communication protocols are built in?

Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee over the built-in RS-485 port. This unit has no fieldbus option card fitted, so PROFIBUS, PROFINET, EtherNet/IP or BACnet/IP would need an MCA option card.

What output current does it deliver at 400 V and at 480 V?

Continuous output current is 3 A / 2.7 A; intermittent current is 3.3 A / 2.97 A. Always size on the motor nameplate current at your supply voltage.

Can this drive be wall mounted without a panel?

Yes. The IP66 / UL Type 4X, A4 frame enclosure is designed for direct mounting.

Type code decoded

FC-102P1K1T4Z66H1XGXXOXSXXXXAXBXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
1.1 kW / 1.5 HPP1K1
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP66 / UL Type 4X, A4 frameZ66
RFI filter
Position 16–17
RFI class A1/B (C1)H1
Brake / Safe Stop
Position 18
No brake chopperX
Local control panel
Position 19
Graphical LCP 102G
PCB coating
Position 20
Standard (uncoated) PCBsX
Mains option
Position 21
No mains optionX
Adaptation A
Position 22
Metric cable entriesO
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
No fieldbus optionAX
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX