131Z2183 Danfoss VLT FC-102 HVAC Drive 2.2 kW / 3.0 HP, 380 - 480 VAC, IP66

131Z2183 Danfoss VLT FC-102 HVAC Drive 2.2 kW / 3.0 HP, 380 – 480 VAC, IP66

Danfoss 131Z2183 VLT HVAC Drive FC-102 frequency converter, 2.2 kW / 3.0 HP, three phase 380-480 V AC, IP66 / NEMA 4X, designed for HVAC motor control in ventilation, heating and air handling applications.

SKU: 131Z2183Alt SKU: FC-102P2K2T4E66H1XGXXOXSXXXXAXBXCXXXXDXMPN: 131Z2183
Price
List Price £1,322.00 ex VAT
Your Price (ex VAT) Save 45%
£727.10 45% OFF
You save £594.90 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £727.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£727.10

Danfoss 131Z2183 at a glance

The Danfoss 131Z2183 is a 2.2 kW / 3.0 HP VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame A5, IP66 / UL Type 4X unit, built for wall mounting in wet, dusty or wash-down locations.

This configuration has RFI class A1/B (C1), no brake chopper, and a graphical LCP 102 control panel. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Enclosure: IP66 / UL Type 4X — built for wall mounting in wet, dusty or wash-down locations.
  • EMC: RFI class A1/B (C1). Check the permitted screened motor cable length in the Danfoss FC 102 Design Guide.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same configuration, different power

This drive2.2 kWDanfoss 131Z2183IP66 / UL Type 4X · frame A5
Larger5.5 kWDanfoss 131Z2186IP66 / UL Type 4X · frame A5View drive →

Same 2.2 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 2.2 kW
Voltage 480 V
Phase Three Phase
IP Rating IP66
EMC Filter Commercial
Series VLT® HVAC Drive FC-102
Product code 131Z2183
Model code FC-102P2K2T4E66H1XGXXOXSXXXXAXBXCXXXXDX
Product type Frequency converter / variable speed drive
Application type HVAC drive
Rated power 2.2 kW / 3.0 HP
Input voltage 380-480 V AC
Input phases Three phase
Enclosure rating IP66 / NEMA 4X
RFI filter Class A1/B (C1)
Frame size A5
Control panel Graphical local control panel
Brake chopper No brake chopper
PCB coating Not coated PCB
Mains option No mains option
A option No A option
B option No B option
Software release Latest release standard software
Gross weight 13.1 kg
Net weight 12.3 kg
Volume 52.36 L
EAN 5710107318148

Frequently asked questions

Which communication protocols are built in?

Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee over the built-in RS-485 port. This unit has no fieldbus option card fitted, so PROFIBUS, PROFINET, EtherNet/IP or BACnet/IP would need an MCA option card.

Can this drive be wall mounted without a panel?

Yes. The IP66 / UL Type 4X enclosure is designed for direct mounting.

Type code decoded

FC-102P2K2T4E66H1XGXXOXSXXXXAXBXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
2.2 kW / 3.0 HPP2K2
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP66 / UL Type 4XE66
RFI filter
Position 16–17
RFI class A1/B (C1)H1
Brake / Safe Stop
Position 18
No brake chopperX
Local control panel
Position 19
Graphical LCP 102G
PCB coating
Position 20
Standard (uncoated) PCBsX
Mains option
Position 21
No mains optionX
Adaptation A
Position 22
Metric cable entriesO
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
No fieldbus optionAX
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX