131Z1640 Danfoss VLT FC-102 HVAC Drive 1.1 kW / 1.5 HP, 380 - 480 VAC, IP55

131Z1640 Danfoss VLT FC-102 HVAC Drive 1.1 kW / 1.5 HP, 380 – 480 VAC, IP55

Danfoss 131Z1640 VLT HVAC Drive FC-102 frequency converter, model code FC-102P1K1T4Z55H2XNXXXXSXXXXAXBXCXXXXDX, rated at 1.1 kW / 1.5 HP with three-phase 380-480 V AC supply, IP55 / Type 12 enclosure, RFI filter, numerical local control panel, not coated PCB and no brake chopper for HVAC motor control applications.

SKU: 131Z1640Alt SKU: FC-102P1K1T4Z55H2XNXXXXSXXXXAXBXCXXXXDXMPN: 131Z1640
Price
List Price £717.00 ex VAT
Your Price (ex VAT) Save 45%
£394.35 45% OFF
You save £322.65 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £394.35
Trade pricing is personalised to your account

Manufacturer Lead Time

£394.35

Danfoss 131Z1640 at a glance

The Danfoss 131Z1640 is a 1.1 kW / 1.5 HP VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame A4, IP55 / UL Type 12, A4 frame unit, built for wall mounting in plant rooms without a separate enclosure.

This configuration has RFI class A2 (C3), no brake chopper, and a numeric LCP 101 control panel. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Enclosure: IP55 / UL Type 12, A4 frame — built for wall mounting in plant rooms without a separate enclosure.
  • EMC: RFI class A2 (C3). Check the permitted screened motor cable length in the Danfoss FC 102 Design Guide.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same configuration, different power

This drive1.1 kWDanfoss 131Z1640IP55 / UL Type 12, A4 frame · frame A4
Larger4 kWDanfoss 131Z1641IP55 / UL Type 12, A4 frame · frame A4View drive →

Same 1.1 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 1.1 kW
Voltage 480 V
Phase Three Phase
IP Rating IP55
Series VLT® HVAC Drive FC-102
SKU 131Z1640
Model code FC-102P1K1T4Z55H2XNXXXXSXXXXAXBXCXXXXDX
Product type Frequency converter / variable speed drive
Rated output power 1.1 kW / 1.5 HP
Input voltage 380-480 V AC
Input phases Three phase
Application HVAC motor control
Enclosure rating IP55 / Type 12
RFI filter RFI filter
Brake chopper No brake chopper
Control panel Numerical local control panel
PCB coating Not coated PCB
Mains option No mains option
Frame size A4
Adaptation A Standard cable entries
Adaptation B No adaptation
Option A No A option
Option B No B option
Option C1 No C1 option
Option D No D option
Software release Latest release standard software

Frequently asked questions

Which communication protocols are built in?

Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee over the built-in RS-485 port. This unit has no fieldbus option card fitted, so PROFIBUS, PROFINET, EtherNet/IP or BACnet/IP would need an MCA option card.

Can this drive be wall mounted without a panel?

Yes. The IP55 / UL Type 12, A4 frame enclosure is designed for direct mounting.

Type code decoded

FC-102P1K1T4Z55H2XNXXXXSXXXXAXBXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
1.1 kW / 1.5 HPP1K1
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP55 / UL Type 12, A4 frameZ55
RFI filter
Position 16–17
RFI class A2 (C3)H2
Brake / Safe Stop
Position 18
No brake chopperX
Local control panel
Position 19
Numeric LCP 101N
PCB coating
Position 20
Standard (uncoated) PCBsX
Mains option
Position 21
No mains optionX
Adaptation A
Position 22
Standard cable entriesX
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
No fieldbus optionAX
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX