131Z0226 Danfoss VLT FC-102 HVAC Drive 45 kW / 60 HP, 380 - 480 VAC, IP20

131Z0226 Danfoss VLT FC-102 HVAC Drive 45 kW / 60 HP, 380 – 480 VAC, IP20

Danfoss 131Z0226 VLT HVAC Drive FC-102 frequency converter, model code FC-102P45KT4E20H3TGXXXXSXXXXA0BXCXXXXDX, rated at 45 kW / 60 HP with three-phase 380-480 V AC supply, IP20 / chassis enclosure, RFI Class A1/B (C1) filter, graphical local control panel, Safe Stop and PROFIBUS DP MCA 101 option for HVAC motor control applications.

SKU: 131Z0226Alt SKU: FC-102P45KT4E20H3TGXXXXSXXXXA0BXCXXXXDXMPN: 131Z0226
Price
List Price £5,811.00 ex VAT
Your Price (ex VAT) Save 45%
£3,196.05 45% OFF
You save £2,614.95 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,196.05
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,196.05

Danfoss 131Z0226 at a glance

The Danfoss 131Z0226 is a 45 kW / 60 HP VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame C3, IP20 / chassis unit, built for mounting inside a control panel or enclosure.

This configuration has RFI class A1/B (C1) with reduced motor cable length, safe Stop, no brake chopper, a graphical LCP 102 control panel, and a PROFIBUS DP MCA 101 fieldbus card. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Intermittent (overload) current: 99 A / 88 A — the normal-overload rating that suits variable-torque fan and pump loads.
  • Enclosure: IP20 / chassis — built for mounting inside a control panel or enclosure.
  • EMC: RFI class A1/B (C1) is met only with a reduced screened motor cable length. Check the maximum length for this frame in the Danfoss FC 102 Design Guide (Technical Documents tab); for longer runs, ask us about an H2 (A2/C3) variant.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same configuration, different power

Smaller37 kWDanfoss 131U6314IP20 / chassis · frame B4View drive →
This drive45 kWDanfoss 131Z0226IP20 / chassis · frame C3

Same 45 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 45 kW
Voltage 480 V
Phase Three Phase
IP Rating IP20
EMC Filter Commercial
Series VLT® HVAC Drive FC-102
SKU 131Z0226
Model code FC-102P45KT4E20H3TGXXXXSXXXXA0BXCXXXXDX
Product type Frequency converter / variable speed drive
Rated output power 45 kW / 60 HP
Rated output current 90 A / 80 A
Input voltage 380-480 V AC
Input phases Three phase
Application HVAC motor control
Enclosure rating IP20 / chassis
RFI filter Class A1/B (C1)
Brake / safety Safe Stop
Control panel Graphical local control panel
Communication option PROFIBUS DP MCA 101
PCB coating Not coated PCB
Mains option No mains option
Frame size C3
Adaptation A Standard cable entries
Adaptation B No adaptation
Option A PROFIBUS DP MCA 101
Option B No B option
Option C0 No C0 option
Option C1 No C1 option
Option D No D option
kVA rating 62.4 kVA
Power loss 843 W
Intermittent current 99 A / 88 A
Dimensions (H × W × D) approx. 550 × 308 × 333 mm
EAN 5710107298334
Net weight approx. 35.84 kg
Gross weight approx. 38.69 kg
Volume approx. 178.336 L

Frequently asked questions

What is the maximum motor cable length with this RFI filter?

The 131Z0226 has the H3 filter: RFI class A1/B (C1) with a reduced motor cable length. The exact limit for this frame is in the Danfoss VLT HVAC Drive FC 102 Design Guide (see Technical Documents). If your screened cable run is longer, contact us and we will suggest an alternative.

Which communication protocols does it support?

This unit is fitted with a PROFIBUS DP MCA 101 card, in addition to the built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee.

Does this drive need to go in an enclosure?

Yes. IP20 / chassis drives are designed to be mounted inside a control panel or enclosure. For wall mounting without a panel, choose an IP55 or IP66 version.

Type code decoded

FC-102P45KT4E20H3TGXXXXSXXXXA0BXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
45 kW / 60 HPP45K
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP20 / chassisE20
RFI filter
Position 16–17
RFI class A1/B (C1) with reduced motor cable lengthH3
Brake / Safe Stop
Position 18
Safe Stop, no brake chopperT
Local control panel
Position 19
Graphical LCP 102G
PCB coating
Position 20
Standard (uncoated) PCBsX
Mains option
Position 21
No mains optionX
Adaptation A
Position 22
Standard cable entriesX
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
PROFIBUS DP MCA 101A0
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX