131X2728 Danfoss VLT FC-102 HVAC Drive 75 kW / 100 HP, 380 - 480 VAC, IP55

131X2728 Danfoss VLT FC-102 HVAC Drive 75 kW / 100 HP, 380 – 480 VAC, IP55

Danfoss 131X2728 VLT HVAC Drive FC-102, a 75 kW / 100 HP three phase HVAC variable frequency drive with 380-480 V AC input, IP55 / Type 12 enclosure, RFI Class A1/B filter, numerical local control panel, PROFIBUS DP MCA 101 and MCB-107 24 V DC backup option.

SKU: 131X2728Alt SKU: FC-102P75KT4E55H1XNCXXXSXXXXA0BXCXXXXD0MPN: 131X2728
Price
List Price £9,255.00 ex VAT
Your Price (ex VAT) Save 45%
£5,090.25 45% OFF
You save £4,164.75 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,090.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,090.25

Danfoss 131X2728 at a glance

The Danfoss 131X2728 is a 75 kW / 100 HP VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame C2, IP55 / UL Type 12 unit, built for wall mounting in plant rooms without a separate enclosure.

This configuration has RFI class A1/B (C1), no brake chopper, a numeric LCP 101 control panel, and a PROFIBUS DP MCA 101 fieldbus card. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Continuous output current: 147 A / 130 A. Size the drive on the motor nameplate current at your actual supply voltage.
  • Intermittent (overload) current: 162 A / 143 A — the normal-overload rating that suits variable-torque fan and pump loads.
  • Enclosure: IP55 / UL Type 12 — built for wall mounting in plant rooms without a separate enclosure.
  • EMC: RFI class A1/B (C1). Check the permitted screened motor cable length in the Danfoss FC 102 Design Guide.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same 75 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 75 kW
Voltage 480 V
Phase Three Phase
IP Rating IP55
EMC Filter Commercial
Series VLT® HVAC Drive FC-102
Model / Code 131X2728
Type code FC-102P75KT4E55H1XNCXXXSXXXXA0BXCXXXXD0
Product type HVAC variable frequency drive
Rated output power 75 kW / 100 HP
Continuous current 147 A / 130 A
Intermittent current 162 A / 143 A
Input voltage 380-480 V AC
Input phases Three phase
Enclosure rating IP55 / Type 12
RFI filter Class A1/B, C1
Brake chopper No brake chopper
Control panel Numerical local control panel
PCB coating Coated PCB
Mains option No mains option
Adaptation A Standard cable entries
Adaptation B No adaptation
A option PROFIBUS DP MCA 101
B option No B option
C1 option No C1 option
D option MCB-107 24 V DC backup
Software Latest release standard software
Frame size C2
Dimensions (H x W x D) 780 x 370 x 332 mm
Depth with option A/B 332 mm
kVA rating 102 kVA
Power loss 1384 W
EAN 5710107045433
Net weight approx. 57.37 kg
Gross weight approx. 60.71 kg
Volume approx. 232.653 litres

Frequently asked questions

Which communication protocols does it support?

This unit is fitted with a PROFIBUS DP MCA 101 card, in addition to the built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee.

What output current does it deliver at 400 V and at 480 V?

Continuous output current is 147 A / 130 A; intermittent current is 162 A / 143 A. Always size on the motor nameplate current at your supply voltage.

Can this drive be wall mounted without a panel?

Yes. The IP55 / UL Type 12 enclosure is designed for direct mounting.

Type code decoded

FC-102P75KT4E55H1XNCXXXSXXXXA0BXCXXXXD0

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
75 kW / 100 HPP75K
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP55 / UL Type 12E55
RFI filter
Position 16–17
RFI class A1/B (C1)H1
Brake / Safe Stop
Position 18
No brake chopperX
Local control panel
Position 19
Numeric LCP 101N
PCB coating
Position 20
Conformal-coated PCBsC
Mains option
Position 21
No mains optionX
Adaptation A
Position 22
Standard cable entriesX
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
PROFIBUS DP MCA 101A0
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
24 V DC back-up (MCB 107)D0