131L2768 Danfoss VLT FC-102 HVAC Drive 22 kW / 30 HP, 380 - 480 VAC, IP66

131L2768 Danfoss VLT FC-102 HVAC Drive 22 kW / 30 HP, 380 – 480 VAC, IP66

Danfoss 131L2768 VLT HVAC Drive FC-102, a 22 kW / 30 HP three phase AC variable frequency drive with 380-480 V AC supply, IP66 / NEMA 4X enclosure, RFI Class A1/B filter and BACnet MCA 109 communication option for HVAC motor control applications.

SKU: 131L2768Alt SKU: FC-102P22KT4E66H3XGXXXXSXXXXAJBXCXXXXDXMPN: 131L2768
Price
List Price £3,961.00 ex VAT
Your Price (ex VAT) Save 45%
£2,178.55 45% OFF
You save £1,782.45 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,178.55
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,178.55

Danfoss 131L2768 at a glance

The Danfoss 131L2768 is a 22 kW / 30 HP VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame B2, IP66 / UL Type 4X unit, built for wall mounting in wet, dusty or wash-down locations.

This configuration has RFI class A1/B (C1) with reduced motor cable length, no brake chopper, a graphical LCP 102 control panel, and a BACnet MCA 109 fieldbus card. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Enclosure: IP66 / UL Type 4X — built for wall mounting in wet, dusty or wash-down locations.
  • EMC: RFI class A1/B (C1) is met only with a reduced screened motor cable length. Check the maximum length for this frame in the Danfoss FC 102 Design Guide (Technical Documents tab); for longer runs, ask us about an H2 (A2/C3) variant.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same configuration, different power

This drive22 kWDanfoss 131L2768IP66 / UL Type 4X · frame B2
Larger30 kWDanfoss 131N4425IP66 / UL Type 4X · frame B2View drive →

Same 22 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 22 kW
Voltage 480 V
Phase Three Phase
IP Rating IP66
EMC Filter Commercial
Series VLT® HVAC Drive FC-102
SKU / Code number 131L2768
Product type AC variable frequency drive
Rated output power 22 kW / 30 HP
Input voltage 380–480 V AC
Input phases Three phase
Output phases Three phase
Protection rating IP66 / NEMA 4X
Frame size B2
RFI filter Class A1/B (C1)
Brake chopper Not included
Local control panel Graphical local control panel
PCB coating Not coated
Mains option No mains option
A option BACnet MCA 109
B option No B option
C1 option No C1 option
D option No D option
Cable entry Standard cable entries
Software Latest release standard software
EAN 5702427735781
Dimensions (H × W × D) approx. 664 × 243 × 261 mm

Frequently asked questions

What is the maximum motor cable length with this RFI filter?

The 131L2768 has the H3 filter: RFI class A1/B (C1) with a reduced motor cable length. The exact limit for this frame is in the Danfoss VLT HVAC Drive FC 102 Design Guide (see Technical Documents). If your screened cable run is longer, contact us and we will suggest an alternative.

Which communication protocols does it support?

This unit is fitted with a BACnet MCA 109 card, in addition to the built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee.

Can this drive be wall mounted without a panel?

Yes. The IP66 / UL Type 4X enclosure is designed for direct mounting.

Type code decoded

FC-102P22KT4E66H3XGXXXXSXXXXAJBXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
22 kW / 30 HPP22K
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP66 / UL Type 4XE66
RFI filter
Position 16–17
RFI class A1/B (C1) with reduced motor cable lengthH3
Brake / Safe Stop
Position 18
No brake chopperX
Local control panel
Position 19
Graphical LCP 102G
PCB coating
Position 20
Standard (uncoated) PCBsX
Mains option
Position 21
No mains optionX
Adaptation A
Position 22
Standard cable entriesX
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
BACnet MCA 109AJ
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX