131F9865 Danfoss VLT HVAC Drive 400 kW/550HP 380-480VAC IP54

131F9865 Danfoss VLT HVAC Drive 400 kW/550HP 380-480VAC IP54

Danfoss 131F9865 VLT HVAC Drive FC 102, a 400 kW / 550 HP three phase AC variable frequency drive designed for HVAC, ventilation, pump, compressor and building services motor control applications.

SKU: 131F9865Alt SKU: FC-102P400T4E54H4XGC3XXSXXXXA0BXCXXXXDXMPN: 131F9865
Price
List Price £52,641.00 ex VAT
Your Price (ex VAT) Save 45%
£28,952.55 45% OFF
You save £23,688.45 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £28,952.55
Trade pricing is personalised to your account

Manufacturer Lead Time

£28,952.55

Danfoss 131F9865 at a glance

The Danfoss 131F9865 is a 400 kW VLT HVAC Drive FC 102 for 3 × 380–480 V AC supplies, made for the fans, pumps and compressors in building services. It is a frame E1, IP54 / UL Type 12 unit, built for wall mounting in plant rooms without a separate enclosure.

This configuration has RFI class A1 (C2), no brake chopper, a graphical LCP 102 control panel, and a PROFIBUS DP MCA 101 fieldbus card. The full type code is decoded alongside the FAQs.

Sizing and installation

  • Enclosure: IP54 / UL Type 12 — built for wall mounting in plant rooms without a separate enclosure.
  • EMC: RFI class A1 (C2). Check the permitted screened motor cable length in the Danfoss FC 102 Design Guide.

FC 102 features for HVAC

  • Built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee — connects to most building management systems without an option card.
  • Fire Mode keeps the drive running during an emergency, for example to keep smoke-extract fans turning.
  • Automatic Energy Optimisation (AEO) cuts motor losses at part load — Danfoss quotes a further 5–15% saving.
  • Pump and fan functions: sleep mode, dry-pump, end-of-curve and broken-belt detection, plus a built-in cascade controller for pump sets.
  • Built-in DC coils limit mains harmonics (EN 61000-3-12).
  • Smart Logic Controller for simple sequencing without a PLC.

Where the energy saving comes from

Centrifugal fans and pumps follow the affinity laws: absorbed power falls with the cube of speed. Running at 80% speed needs roughly half the power of full speed (0.8³ ≈ 0.51, before motor and drive losses) — which is why speed control pays back faster on fans and pumps than almost any other load.

Other sizes and enclosures

Same configuration, different power

Smaller315 kWDanfoss 134H2358IP54 / UL Type 12 · frame D7HView drive →
This drive400 kWDanfoss 131F9865IP54 / UL Type 12 · frame E1

Same 400 kW rating, other enclosures

Typical applications

✓  Supply and extract fans in air-handling units ✓  Chilled- and hot-water circulation pumps ✓  Cooling towers and condenser fans ✓  Booster sets and multi-pump stations ✓  Ventilation and smoke-extract systems

Technical Specifications

Tick the specs you need, then view products that match.

Power 400 kW
Voltage 480 V
Phase Three Phase
IP Rating IP54
EMC Filter Commercial
Series VLT HVAC Drive FC 102
Model / code 131F9865
Full type code FC-102P400T4E54H4XGC3XXSXXXXA0BXCXXXXDX
Product type AC variable frequency drive
Rated output power 400 kW
Horsepower rating 550 HP
Input voltage 380–480 V AC
Input phases 3-phase
Output phases 3-phase
EMC / RFI filter RFI Class A1 (C2)
Brake chopper No
Mains option Mains disconnect and fuse
Communication option PROFIBUS DP MCA 101
PCB coating Coated PCB
Frame size E1
Protection rating IP54 / Type 12
Net weight approx. 297 kg
Gross weight approx. 337 kg
EAN 5710107110063

Frequently asked questions

Which communication protocols does it support?

This unit is fitted with a PROFIBUS DP MCA 101 card, in addition to the built-in RS-485 protocols: Danfoss FC, Modbus RTU, BACnet MS/TP, Metasys N2 and FLN Apogee.

Can this drive be wall mounted without a panel?

Yes. The IP54 / UL Type 12 enclosure is designed for direct mounting.

Type code decoded

FC-102P400T4E54H4XGC3XXSXXXXA0BXCXXXXDX

G fitted / defines this unit   X not fitted / standard

Product series
Position 1–6
VLT HVAC Drive FC 102FC-102
Power size
Position 7–10
400 kWP400
Mains voltage
Position 11–12
3 × 380–480 V ACT4
Enclosure
Position 13–15
IP54 / UL Type 12E54
RFI filter
Position 16–17
RFI class A1 (C2)H4
Brake / Safe Stop
Position 18
No brake chopperX
Local control panel
Position 19
Graphical LCP 102G
PCB coating
Position 20
Conformal-coated PCBsC
Mains option
Position 21
Mains disconnect + fuses3
Adaptation A
Position 22
Standard cable entriesX
Adaptation B
Position 23
StandardX
Software release
Position 24–27
Latest standard releaseSXXX
Software language
Position 28
Standard language packageX
A option (fieldbus)
Position 29–30
PROFIBUS DP MCA 101A0
B option (I/O)
Position 31–32
No B optionBX
C0 option
Position 33–34
No C0 optionCX
C1 option
Position 35
No C1 optionX
C option software
Position 36–37
NoneXX
D option
Position 38–39
No D optionDX