Danfoss VLT Soft Starter MCD 500 MCD50428CT5G4X

Danfoss VLT Soft Starter MCD 500 MCD50428CT5G4X

Danfoss 175G5515 VLT Soft Starter MCD50564CT5G4X00CV1 soft starter for controlled starting and stopping of industrial three-phase motors with 564 A operational current.

SKU: 175G5515Alt SKU: MCD50428CT5G4X00CV1MPN: 175G5515
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Danfoss 175G5515 Soft Starter?

The Danfoss 175G5515 is a heavy-duty VLT® Soft Starter MCD 500 engineered for the controlled starting and stopping of large three-phase induction motors in demanding industrial environments. With the type code MCD5-0428C-T5-G4X-00-CV1, this intelligent digital soft starter combines adaptive motor control, integrated bypass technology and comprehensive protection to maximise equipment reliability and operational efficiency.

Designed for high-power industrial applications, the MCD 500 series reduces electrical inrush current and mechanical shock during motor acceleration and deceleration. Adaptive Acceleration Control automatically optimises the start and stop profile to suit the connected load, helping to extend the service life of motors, gearboxes, conveyors, pumps and other driven equipment while reducing maintenance costs.

With a 428 A rated operational current, a three-phase 200-525 V AC mains supply and a 24 V AC/DC control supply, the Danfoss 175G5515 is ideally suited to large pumps, compressors, crushers, conveyors, fans and heavy process machinery. The integrated bypass contactor improves efficiency by reducing heat generation and power losses once the motor reaches full operating speed.

Key Advantages

  • Industrial digital soft starter for large three-phase induction motors.
  • 428 A rated operational current for high-power applications.
  • Three-phase 200-525 V AC operating voltage.
  • Integrated bypass contactor improves efficiency and reduces heat dissipation.
  • Adaptive Acceleration Control provides smooth and repeatable motor starting and stopping.
  • Advanced motor protection helps maximise uptime and reduce maintenance costs.

Key Features

  • Danfoss VLT® Soft Starter MCD 500 series.
  • 428 A rated operational current.
  • Type code: MCD5-0428C-T5-G4X-00-CV1.
  • Three-phase 200-525 V AC mains supply.
  • 24 V AC/DC control supply.
  • Integrated internal bypass contactor.
  • Adaptive Acceleration Control.
  • Graphical keypad with intuitive programming.
  • Integrated motor thermal model and comprehensive protection functions.
  • Support for optional industrial communication modules.

Reliable Motor Control for Heavy Industrial Equipment

The Danfoss MCD 500 gradually controls the voltage supplied to the motor during acceleration and deceleration. This reduces starting current, torque shock and mechanical wear while improving the longevity of motors and connected equipment.

Its intelligent protection system continuously monitors overload, phase loss, current imbalance, excessive start time, motor temperature and supply conditions, helping maximise equipment uptime and maintain reliable industrial production.

Typical Applications

  • Large industrial pumping systems.
  • Bulk material handling conveyors.
  • Heavy-duty compressors.
  • Industrial fans and ventilation equipment.
  • Mining and quarry machinery.
  • Water and wastewater treatment plants.
  • Process manufacturing and automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Power 315 kW
Current 428 A
Voltage 24 V
Phase Three Phase
IP Rating IP00
Series VLT® Soft Starter MCD 500
Part number 175G5515
Product type Soft starter
Rated current 564 A
Duty rating AC53a heavy-duty operation
Input voltage 200–525 V AC
Input phases 3-phase
Control voltage 24 VAC/VDC
Frequency 50 / 60 Hz
Protection rating IP00
Mounting type Panel mounting
Frame size G4 / Frame size 4
Integrated bypass No external bypass required
Motor protection Electronic overload and thermal protection
Motor power range up to approx. 315 kW at 400 V
EAN 5710107568024

Frequently Asked Questions

What is the Danfoss 175G5515 used for?

The Danfoss 175G5515 provides controlled starting and stopping of large three-phase induction motors while reducing electrical inrush current and mechanical stress.

What is the current rating of the Danfoss 175G5515?

The unit has a 428 A rated operational current, making it suitable for high-power industrial motor applications.

What supply voltage does this soft starter require?

The Danfoss 175G5515 operates from a three-phase 200-525 V AC mains supply.

Does the Danfoss 175G5515 include an integrated bypass contactor?

Yes. The MCD 500 incorporates an integrated bypass contactor that improves efficiency by reducing heat generation during normal motor operation.

Where is the Danfoss 175G5515 typically installed?

It is designed for installation inside industrial electrical control panels serving large pumps, compressors, conveyors, crushers and other heavy-duty motor-driven equipment.

Trusted by Industrial Engineers Worldwide

Danfoss VLT® Soft Starter MCD 500 units are trusted worldwide by automation engineers, OEM machine builders and industrial maintenance professionals for delivering reliable motor protection, efficient starting performance and dependable operation in demanding industrial applications.