Danfoss VLT Compact Starter MCD 200 MCD201045T4CV1

Danfoss VLT Compact Starter MCD 200 MCD201045T4CV1

Danfoss 175G5182 VLT Compact Starter MCD 201 soft starter for three-phase motors, rated 45 kW and 85 A with 200–440 V AC operation and integrated bypass functionality.

SKU: 175G5182Alt SKU: MCD201045T4CV1MPN: 175G5182
Price
List Price £874.00 ex VAT
Your Price (ex VAT) Save 5%
£830.30 5% OFF
You save £43.70 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £830.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£830.30

Why Choose the Danfoss 175G5182 VLT® Soft Starter?

The Danfoss 175G5182 is a compact and high-performance VLT® Soft Starter MCD 201 designed to provide controlled starting and stopping of three-phase induction motors. By limiting electrical inrush current and reducing mechanical shock during start-up, it helps extend the service life of motors, couplings, gearboxes and driven equipment while improving overall system reliability.

As part of the proven Danfoss VLT® MCD 201 Soft Starter series, this model incorporates an integrated bypass contactor for improved operating efficiency and reduced heat generation during normal running. Featuring a 24 V AC/DC control supply, it is ideal for OEM machine builders, panel builders and industrial maintenance engineers requiring dependable motor starting in industrial automation systems.

Rated for motors up to 45 kW with a three-phase 200-440 V AC supply, the Danfoss 175G5182 is suitable for pumps, fans, conveyors, compressors and a wide range of industrial machinery. Its compact B-frame panel-mounted design allows straightforward installation inside electrical control cabinets.

Key Advantages

  • Compact soft starter designed for industrial motor applications.
  • Supports motors up to 45 kW.
  • Three-phase 200-440 V AC operation.
  • Integrated bypass contactor improves efficiency and reduces heat generation.
  • 24 V AC/DC control supply for flexible automation integration.
  • Reduces mechanical wear and electrical stress during motor starting.

Key Features

  • Danfoss VLT® Soft Starter MCD 201 series.
  • 45 kW rated motor power.
  • 85 A rated operational current.
  • Three-phase 200-440 V AC input supply.
  • 24 V AC/DC control supply (CV1).
  • Integrated bypass contactor.
  • Adjustable acceleration and deceleration ramps.
  • Compact B-frame panel mounting design.

Reliable Motor Starting for Industrial Applications

Soft starters gradually increase motor voltage during start-up, reducing current surges and mechanical shock while improving equipment longevity. This delivers smoother machine operation, lower maintenance costs and improved reliability across industrial processes.

The Danfoss VLT® MCD 201 range provides an economical solution wherever controlled motor starting is required without the complexity of a variable frequency drive. Its integrated bypass contactor further improves operating efficiency during continuous running.

Typical Applications

  • Industrial pumps.
  • HVAC fans and ventilation systems.
  • Conveyor systems.
  • Compressors.
  • Material handling equipment.
  • General industrial machinery.

Technical Specifications

Tick the specs you need, then view products that match.

Motor Protection No
Coil / Supply Voltage 24 V AC/DC
Voltage 230 V, 400 V
Power 45 kW
Current 85 A
Phase Three Phase
IP Rating IP20
Series VLT® Soft Starter MCD 200
SKU 175G5182
Product type Compact soft starter
Rated motor power 45 kW
Rated current 85 A
Heavy-duty current approx. 72 A
Input voltage 200–440 V AC
Input phases 3-phase
Control voltage 24 VAC/VDC
Frequency 50 / 60 Hz
Protection rating IP20
Mounting type Panel / DIN rail mounting
Frame size B-frame
Dimensions (H × W × D) approx. 215 × 145 × 193 mm
Weight approx. 4 kg net
Operating temperature approx. -10°C to +60°C
EAN 5702427098220

Frequently Asked Questions

What is the Danfoss 175G5182 used for?

It provides controlled starting and stopping of three-phase AC motors while reducing electrical inrush current and mechanical stress.

What motor power does it support?

The Danfoss 175G5182 is designed for motors up to 45 kW.

What supply voltage does it require?

The unit operates from a three-phase 200-440 V AC supply with a 24 V AC/DC control supply.

Does it include an integrated bypass?

Yes. The unit incorporates an integrated bypass contactor that improves efficiency while reducing heat generation during normal operation.

Where is the Danfoss 175G5182 typically installed?

It is commonly installed inside industrial control panels for pumps, fans, compressors, conveyors and other motor-driven machinery.

Trusted by Industrial Professionals Worldwide

Danfoss VLT® Soft Starters are trusted by OEMs, panel builders and maintenance engineers for dependable motor protection, compact installation and reliable performance across demanding industrial applications.