Lovato 51ADX0310 severe-duty three-phase soft starter rated at 310 A for 208–415 V AC asynchronous motors, with adjustable current limitation, comprehensive motor protection and provision for an external bypass contactor.
£8,495.20
The Lovato 51ADX0310 is an advanced three-phase soft starter designed for controlled starting and stopping of asynchronous three-phase motors in severe-duty industrial applications. As part of the Lovato Electric ADX soft starter series, it is rated for starting currents up to 5 × Ie and is specifically predisposed for use with an external bypass contactor.
The 51ADX0310 provides three-phase control with torque or voltage ramp starting and adjustable current limitation. It also supports torque-ramp, voltage-ramp and free-wheel stopping, together with motor thermal overload protection, torque control, kick start, dynamic braking, PTC motor protection and extensive supply, motor and starter protection functions.
With a rated starter current of 310 A and a three-phase 208–415 V AC rated supply, the 51ADX0310 has IEC motor ratings of 90 kW at 230 V AC and 160 kW at 400 V AC. Forced cooling and provision for an external bypass contactor make it suitable for demanding high-power motor-starting applications.
Soft starters progressively control the electrical power supplied to a motor during acceleration, helping reduce the high starting current and mechanical stress associated with direct-on-line starting. The Lovato 51ADX0310 provides three-phase control with configurable torque or voltage ramp starting, allowing acceleration to be matched to the requirements of the motor and driven equipment.
The 51ADX0310 is predisposed for connection to an external bypass contactor rather than incorporating an internal bypass. Its protection functions cover conditions including supply phase loss, phase sequence errors, voltage and frequency limits, motor overload, locked rotor, current asymmetry, overcurrent and starter overtemperature.
Tick the specs you need, then view products that match.
| Motor Protection | Yes | |
|---|---|---|
| Current | 310 A | |
| Power | 160 kW | |
| Phase | Three Phase | |
| HS Code | 85371098 | |
| Manufacturer | Lovato Electric | |
| Series | ADX | |
| Model | 51ADX0310 | |
| Product type | Advanced three-phase soft starter | |
| Motor type | Asynchronous three-phase | |
| Duty | Severe duty, starting current up to 5 × Ie | |
| Rated starter current | 310 A | |
| Rated supply voltage | 208–415 V AC | |
| Auxiliary supply voltage | 208–240 V AC | |
| Rated frequency | 50/60 Hz | |
| Rated motor power at 230 V AC | 90 kW | |
| Rated motor power at 400 V AC | 160 kW | |
| UL motor rating at 220–240 V AC | 100 HP | |
| UL motor rating at 380–415 V AC | 150 HP | |
| UL motor rating at 440–480 V AC | 250 HP | |
| Number of controlled phases | 3 | |
| Built-in bypass | No | |
| External bypass | Predisposed for external bypass contactor | |
| Cooling system | Forced cooling | |
| Display | Backlit LCD, 2 × 16 characters | |
| Starting method | Torque or voltage ramp with current limitation | |
| Stopping methods | Torque ramp, voltage ramp and free-wheel stop | |
| Braking method | DC dynamic braking with external relay | |
| Digital inputs | 3 | |
| Analogue inputs | 1 | |
| Digital outputs | 4 | |
| Analogue outputs | 1 | |
| Analogue output | 0–20 mA or 4–20 mA | |
| Protection rating | IP00 | |
| Pollution degree | 3 | |
| Mounting type | Screw fixing | |
| Operating temperature | -10 to +55 °C | |
| Storage temperature | -30 to +70 °C | |
| Maximum altitude without derating | 1000 m | |
| Maximum relative humidity | 95% without condensation or dripping | |
| Dimensions (W × H × D) | 640 × 600 × 380 mm | |
| Weight | 48.9 kg | |
| EAN | 8013975064030 |
The Lovato 51ADX0310 is an advanced three-phase soft starter designed for controlled starting and stopping of asynchronous three-phase motors in severe-duty industrial applications.
The 51ADX0310 has a rated starter current of 310 A.
Under IEC ratings at up to 40 °C, the soft starter is rated for 90 kW at 230 V AC and 160 kW at 400 V AC.
No. The Lovato 51ADX0310 is predisposed for an external bypass contactor, which must be provided separately when required by the installation.
The 51ADX0310 has a three-phase rated supply voltage of 208–415 V AC and requires a 208–240 V AC auxiliary supply.
Lovato Electric ADX soft starters provide advanced three-phase motor starting and stopping control, combining configurable torque and current control, comprehensive motor protection and external bypass capability for demanding industrial applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.