136G8794 Danfoss MCD Soft Starter series MCD60410BT5S2X00CV2

136G8794 Danfoss MCD Soft Starter series MCD60410BT5S2X00CV2

Danfoss 136G8794 MCD60410BT5S2X00CV2 VLT Soft Starter MCD 600 with 410 A current rating, three-phase 200-525 V AC supply, integrated bypass contactor, IP00 frame size S2 design and 110-120 V AC or 220-240 V AC control voltage.

SKU: 136G8794Alt SKU: MCD60410BT5S2X00CV2MPN: 136G8794
Price
List Price £3,741.00 ex VAT
Your Price (ex VAT)
£3,741.00
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,741.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,741.00

Why Choose the Danfoss 136G8794 VLT MCD 600 Soft Starter?

The Danfoss 136G8794 is a high-performance VLT MCD 600 soft starter designed to provide smooth and controlled starting and stopping of three-phase AC motors in demanding industrial applications. As part of the advanced Danfoss VLT MCD 600 series, it combines intelligent motor control, integrated protection functions and adaptive starting technology to improve equipment reliability and operational efficiency.

The MCD 600 soft starter uses advanced current measurement and feedback control to optimise motor ramp profiles during acceleration and deceleration. Its Adaptive Acceleration Control (AAC) automatically applies the most suitable starting and stopping profile for each application, helping reduce mechanical stress, electrical inrush current and equipment wear.

With a rated current of 410 A, a three-phase 200–525 V AC supply, integrated bypass contactor and an S2 frame IP00 enclosure, the Danfoss 136G8794 is ideal for industrial motor applications including pumps, fans, compressors, conveyors and processing machinery.

Key Advantages

  • Advanced Danfoss VLT MCD 600 soft starter for industrial motor control.
  • 410 A current rating suitable for medium and heavy-duty three-phase motors.
  • Three-phase 200–525 V AC operation for flexible industrial installation.
  • Integrated bypass contactor improves efficiency during normal motor operation.
  • Adaptive Acceleration Control provides smooth motor starting and stopping.
  • Advanced protection and diagnostics help improve system uptime.

Key Features

  • Danfoss VLT Soft Starter MCD 600 series.
  • 410 A nominal current rating.
  • Three-phase 200–525 V AC mains supply.
  • Integrated bypass contactor.
  • IP00 protection rating.
  • S2 frame size for high-current applications.
  • 110–120 VAC or 220–240 VAC control voltage.
  • Adaptive Acceleration Control (AAC).
  • Emergency mode and pump clean functionality.
  • USB programming and configuration interface.
  • Four-line graphical display.
  • Optional Ethernet and serial communication modules.

Reliable Motor Starting for Industrial Systems

Soft starters such as the Danfoss VLT MCD 600 reduce the electrical and mechanical stress associated with direct-on-line motor starting. By controlling voltage and current during startup and stopping, they provide smoother acceleration, reduced wear and improved motor system reliability.

The MCD 600 platform is designed for industrial automation systems requiring dependable motor protection, flexible communication and simplified commissioning. Integrated features such as pump clean, PowerThrough operation and advanced event monitoring support efficient long-term operation.

Typical Applications

  • Industrial pumps and water treatment systems.
  • Fans and ventilation equipment.
  • Compressors and HVAC machinery.
  • Conveyors and material handling systems.
  • Mixers and processing equipment.
  • Manufacturing and automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Motor Protection Yes
Coil / Supply Voltage 110–240 V AC
Voltage 230 V, 400 V, 480 V
Power 284 kW
Current 410 A
Phase Three Phase
IP Rating IP00
Series VLT Soft Starter MCD 600
Product ID 136G8794
Product type Soft starter
Rated current 410 A
Input voltage 200-525 V AC
Input phases Three phase
Control voltage 110-120 V AC or 220-240 V AC
Integrated bypass Yes
Frame size S2 / Frame size 2
Protection rating IP00
Enclosure type Chassis / protected panel mounting
Rated frequency 50 / 60 Hz
Display 4-line graphical display
Typical motor rating up to approx. 284 kW depending on voltage and application
Dimensions (W × H × D) approx. 216 × 523 × 243 mm
Net weight approx. 15.5 kg
Gross weight approx. 16.3 kg
GTIN / EAN 5710108652906

Frequently Asked Questions

What is the Danfoss 136G8794 used for?

The Danfoss 136G8794 is a VLT MCD 600 soft starter used for controlled acceleration and stopping of three-phase AC motors in industrial applications.

What current rating does this soft starter support?

The Danfoss 136G8794 supports a rated current of 410 A.

What voltage supply does the unit require?

The MCD60410BT5S2X00CV2 operates with a three-phase 200–525 V AC supply.

Does the Danfoss 136G8794 include a bypass contactor?

Yes, this model includes an integrated bypass contactor to improve efficiency during normal motor operation.

Where is this soft starter installed?

The unit is typically installed inside electrical control panels for industrial motor control applications.

Trusted by Industrial Automation Professionals Worldwide

Danfoss VLT MCD 600 soft starters are trusted by engineers and machine builders to deliver reliable motor control, reduced mechanical stress and efficient operation across demanding industrial environments.