1SAJ929501R0850 ABB CT5L850R/4 3-Phase Current Transformer 400–850 A

1SAJ929501R0850 ABB CT5L850R/4 3-Phase Current Transformer 400–850 A

ABB CT5L850R/4 1SAJ929501R0850 is a three-phase current transformer with a 400–850 A AC primary current range and 4 A secondary output for high-current motor measurement with UMC100.3 motor controllers.

SKU: 1SAJ929501R0850Alt SKU: CT5L850R/4MPN: 1SAJ929501R0850
Price
List Price £520.17 ex VAT
Your Price (ex VAT)
£520.17
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £520.17
Trade pricing is personalised to your account

Manufacturer Lead Time

£520.17

Why Choose the ABB CT5L850R/4 3-Phase Current Transformer?

The ABB CT5L850R/4, order code 1SAJ929501R0850, is a three-phase current transformer designed for high-current motor monitoring applications with the ABB UMC100.3 Universal Motor Controller. It extends the current measurement capability of the motor management system, allowing the UMC100.3 to be applied to larger industrial motors with nominal currents above its direct measurement range.

As part of ABB's CT4L/CT5L current transformer range, the CT5L850R/4 features linear current transformer characteristics and is purpose-designed for integration with ABB motor management equipment. The three motor phase conductors pass through the transformer, enabling all three phase currents to be transformed for measurement by the connected UMC100.3.

The CT5L850R/4 supports a rated primary current range of 400–850 A AC and has a transformation ratio of 212.5:1, corresponding to 850 A primary / 4 A secondary at the upper rating. This makes it the highest-current model in the CT4L/CT5L family and suitable for demanding high-power motor control installations.

Key Advantages

  • Purpose-built three-phase current transformer for ABB UMC motor management systems.
  • 400–850 A AC rated primary current range for high-current motors.
  • 850 A / 4 A transformation at the upper current rating.
  • 212.5:1 transformer ratio for accurate current scaling.
  • Linear current transformer characteristics support reliable motor current measurement.
  • Allows UMC100.3 controllers to monitor motors with nominal currents above 63 A.

Key Features

  • ABB CT5L850R/4 three-phase current transformer.
  • ABB order code 1SAJ929501R0850.
  • 400–850 A AC rated primary current range.
  • 850 A primary / 4 A secondary current.
  • 212.5:1 current transformation ratio.
  • Designed for use with ABB UMC100.3.
  • Suitable for motor currents greater than 63 A.
  • Three-phase design monitors all three motor phases.
  • Linear current transformer characteristics.
  • UMC100.3 combinations support industrial approvals including ABS, ATEX, CCC, cULus and DNV-GL.

High-Current Measurement for UMC100.3 Motor Management

The ABB UMC100.3 Universal Motor Controller provides motor protection, control, diagnostics and communication functions. For motors whose operating currents exceed the controller's direct current measurement range, an external current transformer is used to scale the three phase currents to levels suitable for measurement by the motor controller.

The CT5L850R/4 fulfils this role for high-current applications, covering primary currents up to 850 A AC. Its three-phase construction and linear characteristics make it suitable for motor control centres, process plants and other installations where dependable current information is required for motor protection and monitoring.

Typical Applications

  • ABB UMC100.3 Universal Motor Controller systems.
  • High-current three-phase industrial motors.
  • Motor control centres and switchgear assemblies.
  • Pumps, fans and compressor motor systems.
  • Conveyors and heavy industrial machinery.
  • Process plant motor protection and monitoring.

Technical Specifications

Series CT5L
Order code 1SAJ929501R0850
Product type 3-phase current transformer
Rated primary current range 400–850 A AC
Maximum primary current 850 A
Secondary current 4 A
Transformation ratio 212.5:1
Number of phases 3
Characteristic Linear
Compatibility ABB UMC100.3 Universal Motor Controller
Application Motor current measurement and protection
ABB product group 311531-FieldBusPlug

Frequently Asked Questions

What is the ABB CT5L850R/4 used for?

The ABB CT5L850R/4 is a three-phase current transformer used to extend the current measurement range of compatible ABB UMC100.3 motor management systems for high-current motors.

What current range does the CT5L850R/4 support?

The CT5L850R/4 has a rated primary current range of 400–850 A AC.

What is the transformation ratio of the CT5L850R/4?

The CT5L850R/4 has a transformation ratio of 212.5:1, corresponding to 850 A primary and 4 A secondary at its upper rating.

Is the CT5L850R/4 compatible with the ABB UMC100.3?

Yes. The CT5L850R/4 is designed for use with the ABB UMC100.3 Universal Motor Controller in applications requiring external current transformation.

What is the ABB order code for the CT5L850R/4?

The ABB order code for the CT5L850R/4 three-phase current transformer is 1SAJ929501R0850.

Trusted ABB Motor Current Measurement

ABB CT4L and CT5L three-phase current transformers extend UMC100.3 motor management to high-current industrial motors, providing purpose-designed current transformation for reliable motor monitoring, protection and control.