Finder 83.02.0.240.0003 83 Series Modular Timer Relay  2 Pole 10 Amp 24...240 Volt AC/DC

Finder 83.02.0.240.0003 83 Series Modular Timer Relay 2 Pole 10 Amp 24…240 Volt AC/DC

Finder 83.02.0.240.0003 is an IECEx, ATEX Zone 2 and HazLoc Class I Division 2 multifunction timer relay featuring a 24-240 V AC/DC supply, eight selectable timing functions, a 0.05-second to 10-day timing range and two changeover contacts for industrial hazardous-location control applications.

SKU: 83.02.0.240.0003Alt SKU: 830202400003MPN: 83.02.0.240.0003
Price
List Price £188.97 ex VAT
Your Price (ex VAT) Save 35%
£122.83 35% OFF
You save £66.14 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £122.83
Trade pricing is personalised to your account

Manufacturer Lead Time

£122.83

Why Choose the Finder 83.02.0.240.0003 ATEX Multifunction Timer Relay?

The Finder 83.02.0.240.0003 is a specialist IECEx, ATEX and HazLoc multifunction timer relay designed for industrial automation and electrical control applications requiring equipment suitable for specified hazardous locations. Part of the Finder 83 Series, this electronic timer combines versatile timing functions, a wide-range AC/DC power supply and two changeover relay outputs in a compact DIN rail-mounted housing.

Featuring a 24–240 V AC/DC nominal supply, 2 changeover (DPDT) output contacts and adjustable timing from 0.05 seconds to 10 days, the Finder 83.02.0.240.0003 offers flexible switching control for industrial processes, machinery and automation systems.

Unlike the standard 83.02 timer, this .0003 variant is specifically designed for hazardous-location applications, with IECEx and ATEX classifications for Zone 2 gas atmospheres and HazLoc suitability for specified Class I, Division 2 installations. Its 22.5 mm wide modular housing, screw terminal connections and selectable timed or instantaneous output arrangement make it a practical solution for industrial control panels requiring certified equipment.

Key Advantages

  • IECEx, ATEX and HazLoc hazardous-location design for appropriately classified industrial installations.
  • ATEX Zone 2, Category 3G classification supports suitable gas-atmosphere applications.
  • Class I, Division 2 HazLoc suitability for specified hazardous-location installations.
  • Eight selectable timing functions provide versatile automation control.
  • 24–240 V AC/DC universal supply supports different industrial control voltages.
  • Two changeover contacts (DPDT) provide flexible switching arrangements.
  • 0.05 seconds to 10 days adjustable timing range accommodates short delays and extended operating cycles.
  • Eight selectable time scales simplify timing configuration.
  • Two timed outputs or one timed and one instantaneous output provide additional control flexibility.
  • External potentiometer adjustment option enables remote timing adjustment.
  • LED status indication assists with commissioning and troubleshooting.
  • 22.5 mm wide housing saves installation space.
  • 35 mm DIN rail mounting supports straightforward panel installation.
  • Screw terminal connections provide secure electrical wiring.

Key Features

  • Finder 83 Series multifunction modular timer.
  • Special hazardous-location variant: 83.02.0.240.0003.
  • IECEx and ATEX Ex classification for specified Zone 2 applications.
  • HazLoc Class I, Division 2 suitability.
  • Eight selectable timing functions: AI, DI, GI, SW, BE, CE, DE and WD.
  • 24–240 V AC/DC nominal supply voltage.
  • 50/60 Hz AC operating frequency.
  • 2 changeover (DPDT) relay contacts.
  • 10 A at 277 V AC contact rating for the hazardous-location version.
  • 5 A at 32 V DC contact rating.
  • 0.05 seconds to 10 days adjustable timing.
  • Eight selectable time scales.
  • Two timed contacts or one timed and one instantaneous contact.
  • External control input for applicable timing functions.
  • Optional external timing potentiometer.
  • LED operating status indicator.
  • Front-mounted timing and function selectors.
  • 35 mm DIN rail mounting.
  • Screw terminal electrical connections.
  • IP20 protection rating.

Eight Selectable Timing Functions

The Finder 83.02.0.240.0003 provides eight timing functions for different industrial switching and process-control requirements:

  • AI – On-delay: Activates the timed output after the selected delay following application of the supply voltage.
  • DI – Interval: Activates the output when the supply is applied and releases it after the selected interval.
  • GI – Delayed pulse: Produces a timed pulse following an initial delay.
  • SW – Symmetrical flasher: Alternates the output between ON and OFF states, beginning with the ON interval.
  • BE – Off-delay with control signal: Delays output release after removal of the external control signal.
  • CE – On- and off-delay with control signal: Provides delayed output operation when the external control signal is applied and removed.
  • DE – Interval with control signal: Starts a timed output interval using the external control input.
  • WD – Watchdog: Provides a retriggerable timing interval initiated through the external control input.

The operating function and output configuration should be selected before energising the timer, following Finder's installation instructions.

Multifunction Timing for Hazardous-Location Control Systems

Electrical control systems installed in potentially explosive atmospheres require equipment selected for the applicable hazardous-area classification, environmental conditions and installation method. The Finder 83.02.0.240.0003 is a specialised timer relay designed for use in specified IECEx, ATEX and North American HazLoc applications.

Its ATEX II 3 G Ex ec nC IIC T4 Gc and IECEx Ex ec nC IIC T4 Gc markings identify suitability for specified Zone 2 gas-atmosphere installations. Its North American hazardous-location classification additionally supports appropriately designed Class I, Division 2 applications.

The relay combines these hazardous-location characteristics with a versatile 24–240 V AC/DC supply, allowing it to be used across a range of industrial control voltage systems. Its two changeover outputs can be configured as two timed contacts or one timed and one instantaneous contact.

The eight timing functions support delayed starting, timed intervals, flashing, pulse generation and watchdog control. Front-mounted adjustment controls simplify configuration, while the optional external potentiometer provides an additional timing adjustment method where permitted by the installation design.

Important: Hazardous-location approval does not mean the timer is suitable for every explosive atmosphere. Installation must comply with the specific certificate conditions, equipment markings, permitted ambient temperatures, wiring requirements and applicable hazardous-area regulations. The device must not be assumed suitable for Zone 0 or Zone 1 applications.

Typical Applications

  • Zone 2 industrial automation control panels.
  • Class I, Division 2 hazardous-location electrical installations.
  • Chemical processing plant auxiliary control systems.
  • Oil and gas equipment control interfaces in appropriately classified areas.
  • Industrial pump and motor timing circuits.
  • Process automation and sequential switching systems.
  • Timed ventilation and auxiliary equipment control.
  • Industrial machinery requiring delayed switching.
  • Pulse generation and intermittent control applications.
  • Watchdog and retriggerable timing circuits.
  • OEM equipment requiring specified hazardous-location approvals.
  • Electrical panel upgrades where an IECEx, ATEX or HazLoc timer is specified.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type DIN rail
Device Type Multifunction timer
Timing Function Multifunction
Switching Current (A) 10 A
Manufacturer Finder
Series 83 Series
Model 83.02.0.240.0003
Product type Hazardous-location multifunction timer relay
Timer technology Electronic multifunction timer with electromechanical relay outputs
Hazardous-location classifications IECEx, ATEX and HazLoc
ATEX marking II 3 G Ex ec nC IIC T4 Gc
IECEx marking Ex ec nC IIC T4 Gc
HazLoc classification Class I, Division 2, Groups A, B, C and D, T4
HazLoc Zone classification Class I, Zone 2
Number of timing functions 8
Timing functions AI, DI, GI, SW, BE, CE, DE and WD
Minimum timing setting 0.05 s
Maximum timing setting 10 days
Number of time scales 8
Nominal supply voltage 24–240 V AC/DC
Minimum operating supply voltage 16.8 V AC/DC
Maximum operating supply voltage 265 V AC/DC
AC supply frequency 50/60 Hz
Power consumption ≤2 VA AC / ≤2 W DC
Output contact configuration 2 CO (DPDT)
Number of output contacts 2 changeover
Selectable output arrangement 2 timed contacts or 1 timed + 1 instantaneous contact
Contact rating at 277 V AC 10 A
Contact rating at 32 V DC 5 A
Operating temperature −20 to +55 °C
Protection rating IP20
Mounting type 35 mm DIN rail
DIN rail standard EN 60715
Terminal type Screw terminals
Timing adjustment Front-mounted rotary selectors and adjustment control
External timing adjustment Optional potentiometer
Timing initiation Supply voltage or external control signal
Status indication LED
Housing width 22.5 mm
Supply terminals A1 / A2
Control input B1
Country of origin Italy

Frequently Asked Questions

What is the Finder 83.02.0.240.0003 used for?

The Finder 83.02.0.240.0003 is an IECEx, ATEX and HazLoc multifunction timer relay designed for delayed switching, pulse generation, interval timing, flashing and watchdog functions in appropriately classified industrial installations.

Is the Finder 83.02.0.240.0003 ATEX and IECEx approved?

Yes. The model is specified with ATEX II 3 G Ex ec nC IIC T4 Gc and IECEx Ex ec nC IIC T4 Gc markings for suitable Zone 2 gas-atmosphere applications, subject to the applicable certificate and installation conditions.

Can this timer relay be installed in Class I, Division 2 hazardous locations?

The Finder 83.02.0.240.0003 is designed for specified Class I, Division 2, Groups A, B, C and D, T4 applications. Installation must follow the applicable hazardous-location certification and electrical requirements.

What supply voltage does the Finder 83.02.0.240.0003 require?

The timer supports a nominal supply range of 24–240 V AC/DC, with AC operation at 50/60 Hz.

How many timing functions does this timer provide?

The relay provides eight selectable timing functions: AI on-delay, DI interval, GI delayed pulse, SW symmetrical flasher, BE off-delay, CE on/off delay, DE interval and WD watchdog.

What is the adjustable timing range?

The Finder 83.02.0.240.0003 provides adjustable timing from 0.05 seconds to 10 days, using eight selectable time scales.

What output contacts does the Finder 83.02.0.240.0003 have?

The timer features two changeover (DPDT) relay contacts, with a specified rating of 10 A at 277 V AC and 5 A at 32 V DC. Permissible switching loads depend on the operating conditions and applicable certification requirements.

Can one output operate immediately while the other is timed?

Yes. The timer supports a selectable arrangement of two timed contacts or one timed and one instantaneous contact, depending on the chosen configuration.

How is the Finder 83.02.0.240.0003 installed?

The relay is designed for 35 mm DIN rail mounting and uses screw terminal electrical connections. Hazardous-location installations must also comply with the relevant certificate conditions and enclosure requirements.

What is the difference between the Finder 83.02.0.240.0003 and 83.02.0.240.0000T?

The 83.02.0.240.0003 is a specialist version designed for specified IECEx, ATEX and HazLoc hazardous-location applications, while the 83.02.0.240.0000T is a standard multifunction timer variant. The .0003 model has specific hazardous-location contact ratings and operating temperature limits that must be considered when selecting equipment.

Specialist Industrial Timing Technology from Finder

The Finder 83.02.0.240.0003 combines multifunction electronic timing, wide-range AC/DC operation and specialised hazardous-location classifications in a compact DIN rail-mounted design, supporting industrial automation engineers and panel builders working with appropriately classified IECEx, ATEX and HazLoc installations.