80.11.0.240.0000T Finder Modular timer Ondelay (AI) DC 24/240V

80.11.0.240.0000T Finder Modular timer Ondelay (AI) DC 24/240V

Finder 80.11.0.240.0000T railway-oriented ON-delay timer relay featuring a 24-240 V AC/DC supply range, adjustable timing from 0.1 seconds to 24 hours, one 16 A SPDT changeover output rated at 250 V AC, screw terminals, LED indication and 17.5 mm DIN rail-mounted construction.

SKU: 80.11.0.240.0000TAlt SKU: 801102400000TMPN: 80.11.0.240.0000T
Price
List Price £90.73 ex VAT
Your Price (ex VAT) Save 35%
£58.97 35% OFF
You save £31.76 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £58.97
Trade pricing is personalised to your account

Manufacturer Lead Time

£58.97

Why Choose the Finder 80.11.0.240.0000T ON-Delay Timer Relay?

The Finder 80.11.0.240.0000T is a railway-oriented ON-delay timer relay designed for controlled switching, delayed activation and electrical sequencing in railway and industrial automation applications. Part of the Finder 80 Series, this modular timer features a wide 24–240 V AC/DC supply range, an adjustable timing range from 0.1 seconds to 24 hours and a single changeover (SPDT / 1 CO) output rated at 16 A.

Unlike multifunction timers, the Finder 80.11.0.240.0000T provides a dedicated ON-delay (AI) timing function. When the supply voltage is applied, the timer begins its preset delay, and the output relay changes state once the selected time has elapsed. Removing the supply resets the timer, making it suitable for delayed equipment activation, contactor sequencing and auxiliary control circuits.

The T suffix identifies the railway-oriented variant, specified for applications involving railway fire behaviour and mechanical environmental requirements, including EN 45545-2 and EN 61373. Its compact 17.5 mm-wide housing, screw terminal connections, LED indication and 35 mm DIN rail mounting make it practical for installation in railway electrical cabinets and industrial control panels.

Key Advantages

  • Dedicated ON-delay function provides straightforward delayed switching without unnecessary programming.
  • 24–240 V AC/DC supply range accommodates a wide selection of industrial and railway control voltages.
  • Adjustable timing from 0.1 seconds to 24 hours supports both short and extended activation delays.
  • 16 A rated changeover contact offers substantial switching capability for compatible electrical loads.
  • 250 V AC rated switching voltage supports common industrial control applications.
  • Railway-oriented T variant is suitable for applications requiring consideration of railway-specific standards.
  • EN 45545-2 railway fire behaviour requirements support appropriately specified railway equipment.
  • EN 61373 shock and vibration requirements support railway environmental applications.
  • Single changeover output provides normally open and normally closed switching connections.
  • Six selectable time scales allow flexible adjustment of the required delay.
  • 17.5 mm slimline construction helps maximise available DIN rail space.
  • Screw terminals and LED indication simplify installation and operational checks.
  • 35 mm DIN rail mounting enables convenient integration into electrical enclosures.

Key Features

  • Finder 80 Series modular timer relay.
  • Type 80.11 single-function ON-delay timer.
  • Special T variant for railway applications.
  • 24–240 V AC supply compatibility.
  • 24–240 V DC supply compatibility.
  • 50/60 Hz AC supply operation.
  • ON-delay (AI) timing function.
  • 0.1 s to 24 h adjustable timing range.
  • Six selectable timing scales.
  • One changeover relay output (1 CO / SPDT).
  • 16 A rated contact current.
  • 250 V AC rated contact voltage.
  • Supply-voltage-triggered timing with reset when supply power is removed.
  • Front-mounted timing adjustment using screwdriver-operated selectors.
  • Integrated LED operating indication.
  • Screw terminal connections.
  • 17.5 mm housing width.
  • 35 mm DIN rail mounting.
  • IP20 protection rating.
  • −25 to +55 °C operating temperature range.

Reliable ON-Delay Timing for Railway and Industrial Control Systems

Electrical control systems frequently require equipment to start only after a defined delay. The Finder 80.11.0.240.0000T provides this functionality through its dedicated AI ON-delay operating mode. When supply voltage is applied, the timing sequence begins while the output remains in its initial state. Once the preset delay expires, the changeover contact transfers, allowing the connected control circuit to operate.

When the supply is removed, the relay returns to its initial state and the timing cycle resets. This makes the device suitable for delayed contactor energisation, staged equipment activation, sequential control and auxiliary switching where a repeatable power-on delay is required.

The timer's 24–240 V AC/DC operating range allows it to be used across different control supply arrangements, while its 16 A changeover contact provides switching capability for appropriately rated loads. For inductive loads, contactors or motor-control equipment, the applicable utilisation category and manufacturer's switching limits should be checked before installation.

The railway-oriented T version is intended for applications where fire behaviour, shock and vibration requirements are important selection criteria. Compliance with a railway equipment specification must be assessed at system level, including the relevant installation conditions and any additional project-specific approvals.

Typical Applications

  • Railway vehicle electrical control systems.
  • Railway auxiliary equipment activation delays.
  • Railway electrical cabinets and control interfaces.
  • Delayed contactor and auxiliary relay energisation.
  • Industrial machinery start-up sequencing.
  • Electrical control panels and distribution equipment.
  • Motor-control circuits requiring timed activation.
  • Ventilation and auxiliary equipment start delays.
  • Automated doors, gates and access-control equipment.
  • Lifts, hoists and material handling systems.
  • Building automation and timed electrical switching.
  • Industrial automation applications requiring a single adjustable ON-delay function.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type DIN rail
Timing Function On-delay
Switching Current (A) 16 A
Device Type Single-function timer
Manufacturer Finder
Series 80 Series
Type 80.11
Manufacturer part number 80.11.0.240.0000T
Product type Single-function ON-delay timer relay
Variant Railway-oriented T version
Supply voltage 24–240 V AC/DC
AC supply frequency 50/60 Hz
Timing function AI — ON delay
Number of timing functions 1
Minimum timing setting 0.1 s
Maximum timing setting 24 h
Number of time scales 6
Timing initiation Application of supply voltage
Reset method Removal of supply voltage
Number of output contacts 1
Output configuration 1 changeover (1 CO)
Output contact arrangement SPDT / 1 Form C
Rated contact current 16 A
Rated contact voltage 250 V AC
Terminal type Screw terminals
Timing adjustment Front-mounted screwdriver-operated selectors
Status indication LED
Mounting type 35 mm DIN rail
DIN rail standard EN 60715
Housing width 17.5 mm
Protection rating IP20
Operating temperature −25 to +55 °C
Railway fire behaviour standard EN 45545-2 + A1:2016
Railway shock and vibration standard EN 61373
Application category Railway and industrial automation
EAN 8012823355092

Frequently Asked Questions

What is the Finder 80.11.0.240.0000T used for?

The Finder 80.11.0.240.0000T is an ON-delay timer relay used to delay the activation of electrical control circuits, contactors and auxiliary equipment in railway and industrial automation applications.

What supply voltage does the Finder 80.11.0.240.0000T accept?

The timer accepts a 24–240 V AC/DC supply, allowing operation from compatible AC or DC control systems. The AC supply frequency is 50/60 Hz.

What timing range and functions does the Finder 80.11.0.240.0000T provide?

The relay provides one dedicated AI ON-delay function, with six selectable time scales covering an adjustable range from 0.1 seconds to 24 hours. The output changes state after the selected delay has elapsed following application of the supply voltage.

What is the difference between the Finder 80.11.0.240.0000T and 80.01.0.240.0000T?

The 80.11.0.240.0000T is a single-function ON-delay timer with a 24–240 V AC/DC supply range. The 80.01.0.240.0000T is a multifunction timer offering six timing functions and a wider 12–240 V AC/DC supply range. Both are railway-oriented variants with one changeover output.

What is the contact rating and how is the Finder 80.11.0.240.0000T installed?

The timer has one SPDT changeover contact rated at 16 A and 250 V AC. It is installed on a 35 mm DIN rail using screw terminal connections, with the timing delay adjusted through the front-mounted selectors. The actual permissible load depends on the relevant switching category and electrical characteristics.

Trusted by Railway Engineers and Industrial Automation Professionals

Finder 80 Series timer relays combine straightforward timing adjustment, dependable changeover switching and compact DIN rail installation. The 80.11.0.240.0000T railway-oriented ON-delay variant offers a practical solution for controlled electrical activation in railway equipment and industrial automation systems.