1SVR730110R3300 ABB CT-AHS.22S Timer OFF-Delay 2C/O

1SVR730110R3300 ABB CT-AHS.22S Timer OFF-Delay 2C/O

ABB CT-AHS.22S electronic OFF-delay time relay with 10 time ranges from 0.05 s to 300 h, 24–48 V DC / 24–240 V AC supply, volt-free triggering and two changeover relay contacts.

SKU: 1SVR730110R3300Alt SKU: CT-AHS.22SMPN: 1SVR730110R3300
Price
List Price £105.18 ex VAT
Your Price (ex VAT) Save 35%
£68.37 35% OFF
You save £36.81 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £68.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£68.37

Why Choose the ABB CT-AHS.22S OFF-Delay Timer?

The ABB CT-AHS.22S is a single-function electronic time relay from the ABB CT-S timer range, designed to provide reliable OFF-delay timing for industrial automation and electrical control systems. It provides a delay-on-break function that keeps the relay output energised for a defined period after the control signal is removed.

The CT-AHS.22S provides 10 selectable time ranges from 0.05 s to 300 h and operates from a rated control supply of 24–48 V DC or 24–240 V AC. A volt-free floating control input provides flexible triggering for machinery, control panels and automated processes.

The timer features 2 c/o (SPDT) relay contacts rated at 250 V / 4 A. Its compact 22.5 mm wide housing uses screw connection technology with double-chamber cage terminals and is suitable for DIN rail installation in industrial control cabinets.

Key Advantages

  • Reliable OFF-delay electronic time relay for industrial automation.
  • Single-function design for straightforward delay-on-break control.
  • 10 selectable time ranges from 0.05 s to 300 h.
  • Operates from 24–48 V DC or 24–240 V AC.
  • 2 c/o (SPDT) relay contacts for flexible switching.
  • 250 V / 4 A rated output contacts.
  • Volt-free floating control input for flexible triggering.
  • Compact 22.5 mm wide DIN rail housing.
  • Screw connection technology with double-chamber cage terminals.
  • Sealable transparent cover available as an accessory to help prevent unauthorised adjustments.

Key Features

  • ABB CT-S timer range.
  • OFF-delay (delay-on-break) timing function.
  • 10 selectable time ranges from 0.05 s to 300 h.
  • 24–48 V DC / 24–240 V AC rated control supply.
  • 2 c/o (SPDT) contacts.
  • 250 V / 4 A rated output contacts.
  • Volt-free floating control input.
  • 50/60 Hz AC or DC operation.
  • Screw connection technology with double-chamber cage connection terminals.
  • DIN rail mounting for compact control cabinet installation.
  • Sealable transparent cover available as an accessory.

Reliable OFF-Delay Timing for Industrial Automation

The ABB CT-AHS.22S provides a dedicated OFF-delay function for applications where relay outputs need to remain active for a defined period after the control signal is removed. This makes it suitable for control circuits requiring predictable delay-on-break operation without the additional complexity of a multifunction timer.

With ten selectable time ranges covering 0.05 s to 300 h, the CT-AHS.22S can accommodate both short machine-control delays and extended process timing requirements. Two changeover relay contacts provide flexible interfacing with contactors, signalling circuits, machinery and other industrial control equipment.

Typical Applications

  • Industrial automation and control panels.
  • Motor and contactor control circuits.
  • Machine sequencing and timed control.
  • Conveyor and production machinery control.
  • Delayed switch-off applications.
  • Process automation and equipment sequencing.
  • Industrial signalling and alarm circuits.
  • Cooling and ventilation run-on control.
  • Control systems requiring extended OFF-delay timing.
  • Applications requiring AC or DC control supply operation.

Technical Specifications

Tick the specs you need, then view products that match.

Contacts 2 C/O
Mounting Type DIN rail
Timing Function Off-delay
Timing Range 0.05 s – 300 h
Switching Current (A) 4 A
Device Type Single-function timer
Series CT-S Time Relays
Product type Electronic time relay
Timer relay type OFF-delay
Timing function OFF-delay (delay-on-break)
Time range 0.05 s–300 h
Number of time ranges 10
Control supply voltage 24–48 V DC / 24–240 V AC
Control input Volt-free floating triggering
Output 2 c/o (SPDT) contacts
Rated operational voltage 250 V
Rated operational current 4 A
Rated frequency 50 / 60 Hz / DC
Rated insulation voltage 500 V input circuit / output circuit, 300 V between output circuits
Rated impulse withstand voltage 4 kV input circuit, 4 kV output circuits
Maximum operating voltage UL/CSA 300 V AC output circuit
Protection rating IP50 housing / IP20 terminals
Operating temperature -25–+60 °C
Storage temperature -40–+85 °C
Mounting type DIN rail mounting
Terminal type Screw terminals, double-chamber cage connection
Housing width 22.5 mm
Dimensions (W × H × D) 22.5 × 85.6 × 103.7 mm
Net weight 0.136 kg
Standards IEC/EN 61812-1, UL 508, CAN/CSA C22.2 No. 14

Frequently Asked Questions

What is the ABB CT-AHS.22S used for?

The CT-AHS.22S is an electronic OFF-delay time relay used to keep control outputs active for a defined period after the control signal is removed in industrial automation and control systems.

What timing function does the CT-AHS.22S provide?

The CT-AHS.22S provides a single OFF-delay (delay-on-break) timing function.

What time range does the CT-AHS.22S provide?

The CT-AHS.22S provides 10 selectable time ranges covering 0.05 s to 300 h.

What control supply voltage does the CT-AHS.22S require?

The CT-AHS.22S operates from a rated control supply of 24–48 V DC or 24–240 V AC.

How many outputs does the CT-AHS.22S have?

The CT-AHS.22S has two changeover (2 c/o) SPDT relay contacts, rated at 250 V / 4 A.