Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder RB.22.9.125.0000 is an industrial bistable latching relay with a 110–125 V DC dual-winding control supply, two 8 A changeover contacts, local SET and RESET push-buttons and compatibility with Finder 90.21 and 90.49 relay sockets.
£194.86
The Finder RB.22.9.125.0000 is an industrial bistable latching relay featuring a 110–125 V DC control supply, two changeover contacts and an 8 A contact rating. Part of the Finder RB Series, this relay is designed for electrical control panels, industrial automation and power generation applications where a switching state must be maintained without continuously energising a relay coil.
Unlike a conventional monostable relay, the Finder RB.22.9.125.0000 uses a dual-winding bistable mechanism with separate SET and RESET functions. A suitable control pulse changes the relay's contact position, and the relay mechanically maintains that position after the pulse is removed. This makes it particularly useful for control systems requiring state retention and reduced continuous coil power consumption.
The relay provides two changeover contacts (2 CO / DPDT), allowing two switching circuits to be controlled through the same latching mechanism. With a nominal contact rating of 8 A at 250 V AC, it supports suitable auxiliary control, signalling and resistive load applications.
The Finder RB.22 design incorporates local SET and RESET push-buttons and supports external control arrangements. Its plug-in construction is intended for compatible Finder 90.21 and 90.49 sockets, providing a practical solution for industrial installations requiring accessible wiring and relay replacement.
The Finder RB.22.9.125.0000 uses a bistable operating mechanism that allows the relay contacts to remain in either of two stable positions without a continuous control supply. This differs from a conventional monostable relay, which normally returns to its rest position when coil power is removed.
The relay incorporates separate SET and RESET windings. Applying an appropriate control pulse to the SET circuit moves the contacts into the set position. Applying a suitable pulse to the RESET circuit returns the contacts to the reset position. Once either operation is completed, the relay retains its selected state without continuous coil energisation.
Its two changeover contacts provide independent common, normally open and normally closed connections. This allows the relay to control two auxiliary circuits, switch between alternative signal paths or provide separate control and status functions.
The integrated SET and RESET push-buttons allow local operation during commissioning and maintenance. The relay also supports remote control arrangements using appropriately wired external push-buttons. Finder provides wiring arrangements for local-only, remote-only and combined local/remote control.
The relay is designed for use with compatible Finder 90.21 and 90.49 sockets. The socket provides the permanent wiring interface, while the relay can be removed or replaced after safe electrical isolation. The correct socket, control wiring and contact load ratings must be verified before installation.
Tick the specs you need, then view products that match.
| Device Type | Latching / Impulse Relay | |
|---|---|---|
| Mounting Type | Plug-in socket | |
| Load Voltage | 400 V AC | |
| Manufacturer | Finder | |
| Series | RB Series | |
| Model | RB.22.9.125.0000 | |
| Product type | Industrial bistable latching relay | |
| Relay configuration | Dual-winding bistable | |
| Number of stable states | 2 | |
| Contact arrangement | 2 CO / DPDT | |
| Number of changeover contacts | 2 | |
| Nominal contact current | 8 A | |
| Peak contact current | 15 A | |
| Nominal contact voltage | 250 V AC | |
| Maximum switching voltage | 400 V AC | |
| Rated AC1 load | 2,000 VA | |
| Rated AC15 load at 230 V AC | 350 VA | |
| Single-phase motor rating at 230 V AC | 370 W | |
| Contact material | Silver-nickel (AgNi) | |
| Nominal coil voltage | 110–125 V DC | |
| Coil voltage code | 9.125 | |
| DC coil operating range | 88–137.5 V DC | |
| Nominal coil power | 4 W | |
| Nominal coil current | Approximately 35 mA | |
| SET operating time | Approximately 10 ms | |
| RESET operating time | Approximately 5 ms | |
| Mechanical endurance | 2 × 106 operations | |
| Electrical endurance at rated AC1 load | 100,000 operations | |
| Operating temperature | -40 °C to +55 °C | |
| Degree of protection | IP20 | |
| Mounting | Plug-in socket mounting | |
| Compatible sockets | Finder 90.21 and 90.49 | |
| Local control | SET and RESET push-buttons | |
| External control | Supported with suitable wiring | |
| Approximate dimensions | 81 × 38 × 25.5 mm | |
| EAN / GTIN-13 | 8012823394374 | |
| Country of manufacture | Brazil |
The Finder RB.22.9.125.0000 is an industrial bistable latching relay used in control circuits that require a switching state to be maintained without continuous coil energisation. Typical applications include industrial automation, power generation and electrical control panels.
The relay has a 110–125 V DC nominal coil supply, with a specified operating range of approximately 88–137.5 V DC.
The relay has an 8 A nominal contact rating at 250 V AC, with a maximum switching voltage of 400 V AC. The permissible load depends on the switching category and application.
The relay has two changeover contacts (2 CO / DPDT), allowing two switching circuits to be controlled through the same bistable mechanism.
Bistable means the relay has two mechanically maintained switching states. A SET or RESET control pulse changes its position, and the selected state remains after the control pulse is removed.
No. The relay is designed for pulse-operated SET and RESET control. It maintains its selected contact state without continuous coil energisation.
Yes. The Finder RB.22 includes integrated SET and RESET push-buttons for local operation. It also supports suitable external push-button control arrangements.
The relay is designed for compatible Finder 90.21 and 90.49 sockets. The socket should be selected according to the manufacturer's wiring and installation requirements.
Both belong to the Finder RB Series of bistable relays. The RB.22 uses a 4 W dual-winding control arrangement, while the RB.14 has a different control configuration and coil power specification. They should not be considered interchangeable without checking the wiring and application requirements.
The specified operating temperature range is -40 °C to +55 °C, making it suitable for appropriately protected industrial installations.
The relay has an IP20 protection rating. It should be installed in a suitable enclosure where protection against moisture, dust and accidental contact is required.
Yes. The relay supports remote SET and RESET control using suitable external push-buttons and the manufacturer's recommended wiring arrangements.
The Finder RB.22.9.125.0000 combines 110–125 V DC bistable control, two 8 A changeover contacts and local or remote SET/RESET operation, providing a practical solution for industrial control systems that require maintained switching states without continuous coil energisation.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.