Finder 99.80.0.230.50 is a 110–240 V AC/DC red LED relay coil indication module featuring a compact plug-in design for compatible Finder 99.80 relay socket assemblies, providing clear visual indication when the relay coil is energised.
£3.02
The Finder 99.80.0.230.50 is a compact red LED relay coil indication module designed for compatible Finder industrial relay sockets. Part of the Finder 99 Series, this plug-in accessory provides clear visual confirmation when a relay coil is energised, making it useful for industrial automation, electrical control panels and machinery control systems.
Designed for an operating voltage range of 110–240 V AC/DC, the Finder 99.80.0.230.50 supports compatible alternating-current and direct-current relay control circuits. Its integrated red LED indicator illuminates when the relay coil is energised, allowing maintenance technicians and electrical engineers to identify active control signals quickly.
The module uses the Finder 99.80 plug-in accessory format, allowing it to be installed in selected compatible Finder relay sockets without the need to mount and wire a separate indicator lamp. This can simplify panel construction, reduce additional wiring and make relay status easier to monitor during commissioning and fault-finding.
For DC applications, correct supply polarity is essential, with positive connected to relay coil terminal A1. The Finder 99.80.0.230.50 is an LED indication accessory rather than a dedicated RC, diode or varistor suppression module, so the appropriate accessory must be selected according to the electrical function required.
In industrial automation systems, relays are commonly used to interface control signals with auxiliary switching circuits. During operation, it is often useful to know whether a relay coil is receiving its energising voltage. The Finder 99.80.0.230.50 provides this information through a red LED indicator incorporated into a compact plug-in accessory.
When the compatible relay coil is energised, the LED illuminates, giving operators and maintenance technicians a visible indication of the applied control signal. This can be particularly useful when inspecting multiple relay assemblies in an electrical cabinet or tracing a control sequence during equipment commissioning.
The module supports 110–240 V AC/DC, making it suitable for appropriately rated AC and DC relay control circuits. In DC installations, the positive supply must be connected to terminal A1 in accordance with the module's polarity requirement. The relay coil voltage and socket configuration must also match the intended installation.
The 99.80 plug-in design enables the indicator to be fitted directly into a compatible Finder socket accessory position. This avoids the need for a separately mounted panel lamp and associated external wiring, helping maintain a compact and organised relay installation.
The Finder 99.80.0.230.50 provides visual indication of coil energisation; it does not independently confirm that the relay contacts have changed state or that the connected load is operating correctly. Where electrical transient suppression is required, an appropriate Finder RC, diode or varistor accessory should be selected separately according to the circuit design.
Tick the specs you need, then view products that match.
| Device Type | Accessory | |
|---|---|---|
| Mounting Type | Plug-in socket | |
| Manufacturer | Finder | |
| Series | 99 Series | |
| Module family | 99.80 | |
| Model | 99.80.0.230.50 | |
| Manufacturer ordering code | 9980023050 | |
| Product type | Plug-in LED indication module | |
| Accessory classification | Relay coil indication accessory | |
| Indication type | LED | |
| LED colour | Red | |
| Operating voltage range | 110–240 V AC/DC | |
| Supply type | AC and DC | |
| Primary function | Visual relay coil energisation indication | |
| LED operating condition | Illuminates when the relay coil is energised | |
| DC polarity | Positive connected to A1 | |
| Installation method | Plug-in connection to compatible Finder relay socket | |
| Module housing colour | Blue | |
| Compatible socket format | Selected Finder sockets accepting 99.80 modules | |
| Compatible relay type | Suitable switching relays installed in compatible Finder sockets | |
| Dedicated suppression component | Not specified for this LED-only module | |
| EAN / GTIN-13 | 8012823105284 | |
| RoHS compliance | Compliant | |
| Relay included | No | |
| Relay socket included | No | |
| Installation environment | Suitable electrical control enclosure |
The Finder 99.80.0.230.50 is a red LED relay coil indication module used to provide a visible indication when a compatible relay coil is energised in an electrical control circuit.
The module operates over a specified voltage range of 110–240 V AC/DC. The relay coil and socket must also be compatible with the selected operating voltage.
The Finder 99.80.0.230.50 features a red LED that illuminates when the relay coil is energised.
Yes. The module is designed for compatible 110–240 V AC/DC relay coil circuits. Correct polarity must be observed when it is used with DC.
For DC operation, the positive supply must be connected to relay coil terminal A1. The complete circuit should be checked against Finder's wiring instructions before energising.
The Finder 99.80.0.230.50 is specified as a red LED indication module. It should not be treated as a dedicated RC, diode or varistor suppression module.
The module is designed for selected Finder relay sockets accepting 99.80 accessories. The exact socket and relay combination must be checked against the manufacturer's compatibility documentation.
Yes. It can provide visual coil indication in compatible PLC-controlled relay circuits, provided the operating voltage, relay coil, output characteristics and socket are suitable.
No. The LED indicates relay coil energisation, not the actual position of the relay contacts or the operating state of the connected load.
The 99.80.0.230.50 is a red LED indication module, while the 99.80.0.230.09 is an RC suppression module. The first provides visual coil status indication, while the second is designed to help suppress relay coil switching transients.
No. The Finder 99.80.0.230.50 is a plug-in accessory module. The compatible relay and relay socket are separate components.
Yes. The Finder 99.80.0.230.50 is listed as RoHS compliant.
The Finder 99.80.0.230.50 provides convenient red LED relay coil indication across a 110–240 V AC/DC operating range, helping engineers monitor compatible relay control circuits and simplify commissioning, diagnostics and maintenance in industrial electrical panels.