Finder 97.P2.7SMA - 97 Series Sockets for 46 Series relays - Rail spec

Finder 97.P2.7SMA – 97 Series Sockets for 46 Series relays – Rail spec

Finder 97.P2.7SMA is an eight-position railway relay socket rated at 8 A and 250 V AC, featuring screwless push-in terminals, DIN rail or panel mounting and an included metal retaining clip for Finder 46.52T two-changeover relays.

SKU: 97.P2.7SMAAlt SKU: 97P27SMAMPN: 97.P2.7SMA
Price
List Price £7.80 ex VAT
Your Price (ex VAT) Save 35%
£5.07 35% OFF
You save £2.73 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5.07
Trade pricing is personalised to your account

Manufacturer Lead Time

£5.07

Why Choose the Finder 97.P2.7SMA Railway Relay Socket?

The Finder 97.P2.7SMA is a specialist 8-position push-in relay socket designed for the Finder 46.52T railway relay. Part of the Finder 97 Series, it provides a reliable connection interface for electrical control, signalling and auxiliary switching applications in railway equipment and other demanding industrial environments.

Rated at 8 A and 250 V AC, the Finder 97.P2.7SMA uses screwless push-in spring terminals to simplify conductor installation. Its eight-terminal arrangement supports the two changeover contacts and coil connections of the compatible Finder 46.52T relay, making it suitable for applications requiring two independently wired switching circuits operated by a common relay coil.

The socket supports 35 mm DIN rail or panel mounting and is supplied with a Finder 097.71 metal retaining clip. This clip helps secure the installed relay in equipment exposed to mechanical movement and vibration, while the plug-in arrangement allows straightforward relay replacement during planned maintenance.

Designed for railway applications, the Finder 97.P2.7SMA meets relevant requirements of EN 45545-2, EN 61373 and EN 50155. With IP20 protection, a -40 to +70 °C operating temperature range and compatibility with selected Finder accessories, it offers a practical connection solution for railway control equipment, rolling stock systems and industrial automation panels.

Key Advantages

  • Railway-oriented relay socket designed for compatible Finder 46.52T relays.
  • 8-position connection arrangement supports two changeover contacts and relay coil connections.
  • 8 A nominal current rating for suitable control and auxiliary switching circuits.
  • 250 V AC nominal voltage rating.
  • Push-in spring terminals enable convenient screwless conductor termination.
  • Metal retaining clip included to help maintain secure relay positioning.
  • 35 mm DIN rail or panel mounting provides installation flexibility.
  • EN 45545-2 compliance addresses railway fire protection requirements for materials.
  • EN 61373 compliance addresses railway shock and vibration requirements.
  • EN 50155 compliance addresses specified railway environmental requirements.
  • IP20 protection rating for installation within suitable electrical enclosures.
  • -40 to +70 °C operating temperature range supports demanding environments.
  • Plug-in relay replacement helps simplify maintenance without disturbing permanent wiring.

Key Features

  • Finder 97 Series relay socket.
  • Model 97.P2.7SMA.
  • 8-position relay connection interface.
  • Designed for Finder 46.52T railway relays.
  • Two-changeover contact arrangement with the compatible relay.
  • 8 A rated current.
  • 250 V AC rated voltage.
  • Screwless push-in spring terminals.
  • 35 mm DIN rail mounting to EN 60715.
  • Panel mounting capability.
  • Finder 097.71 metal retaining clip supplied with the SMA version.
  • IP20 protection category.
  • 6 kV impulse dielectric strength between coil and contacts under specified test conditions.
  • -40 to +70 °C ambient operating temperature.
  • 8 mm conductor stripping length.
  • Compatible with selected Finder 097.52 and 097.42 jumper links.
  • Compatible with Finder 86.30T timing accessories in suitable configurations.
  • Railway fire, vibration and environmental compliance for specified installation conditions.

Reliable Railway Relay Connections for Vibration-Prone Control Equipment

The Finder 97.P2.7SMA provides a dedicated connection interface for the Finder 46.52T railway relay. Its eight-position arrangement accommodates the relay coil and two changeover contact sets. Each contact set has common, normally open and normally closed connections, enabling two separate circuits to change state when the relay coil is energised.

This arrangement is particularly useful in railway control and auxiliary signalling systems where multiple electrical functions must respond to a common control signal. For example, a suitable relay assembly can be used to switch one auxiliary circuit while providing a corresponding status signal through the second contact set. The actual switching capacity and operating voltage depend on the installed relay and the characteristics of the connected loads.

The push-in terminal technology helps simplify installation during railway equipment manufacturing and maintenance. Appropriately prepared conductors can be inserted into the spring terminals without conventional screw tightening. Finder specifies an 8 mm stripping length and conductor capacities up to 2.5 mm² for a single conductor, subject to the stated wiring configuration.

Railway installations can expose electrical components to vibration, mechanical shock and varying environmental conditions. The metal retaining clip helps keep the compatible relay seated in the socket, while the product's specified compliance with EN 61373 and EN 50155 supports its use in appropriately designed railway electrical equipment. Compliance of the complete equipment assembly must still be assessed against the relevant application requirements.

For additional functionality, compatible Finder 86.30T timer modules can be used in suitable relay configurations. Selected 097.52 and 097.42 jumper links can also simplify common electrical connections between appropriate sockets. The circuit must be safely isolated before relay replacement, accessory installation or maintenance.

Typical Applications

  • Railway rolling stock electrical control panels.
  • Train auxiliary control and signalling circuits.
  • Railway equipment interface assemblies.
  • Control systems exposed to vibration and mechanical shock.
  • Two-changeover relay switching applications.
  • Railway vehicle monitoring and status indication.
  • Industrial automation and machinery control.
  • Electrical interlocking and auxiliary control circuits.
  • OEM railway electrical equipment manufacturing.
  • Maintenance of compatible Finder 46.52T relay installations.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Relay Socket
Terminal Type Push-in
Switching Current (A) 8 A
Mounting Type DIN rail, Panel
Manufacturer Finder
Series 97 Series
Model 97.P2.7SMA
Alternative part number formatting 97.P2.7 SMA
Product type Railway and industrial plug-in relay socket
Socket configuration 8 positions
Compatible relay Finder 46.52T
Compatible relay series Finder 46 Series railway relays
Compatible contact arrangement 2 changeover contacts (2 CO)
Rated current 8 A
Rated voltage 250 V AC
Terminal type Push-in spring terminals
Connection method Screwless push-in connection
Mounting type DIN rail or panel mounting
DIN rail size 35 mm
DIN rail standard EN 60715
Protection category IP20
Ambient operating temperature -40 to +70 °C
Impulse dielectric strength between coil and contacts 6 kV (1.2/50 µs)
Conductor stripping length 8 mm
Minimum solid conductor cross-section 0.5 mm²
Minimum stranded conductor cross-section 0.5 mm²
Maximum solid conductor capacity 1 × 2.5 mm² or 2 × 1.5 mm²
Maximum stranded conductor capacity 1 × 2.5 mm² or 2 × 1.5 mm²
Relay retention Metal retaining clip
Included retaining clip Finder 097.71
Compatible jumper accessories Finder 097.52 and 097.42, 2-way
Compatible timer accessory Finder 86.30T
Railway fire protection standard EN 45545-2:2020
Railway vibration and shock standard EN 61373, Category 1, Class B
Railway environmental standard EN 50155, OT4/ST1 classification
Relay coil voltage Determined by the installed Finder 46.52T relay
Relay supplied No; compatible relay selected separately

Frequently Asked Questions

What is the Finder 97.P2.7SMA used for?

The Finder 97.P2.7SMA is an 8-position push-in relay socket designed for the Finder 46.52T railway relay. It provides electrical connections for relay coil and contact circuits in railway control equipment, industrial automation and auxiliary switching applications.

Which relay is compatible with the Finder 97.P2.7SMA?

The socket is specifically designed for the Finder 46.52T railway relay, which provides two changeover contacts. The exact relay coil voltage must be selected according to the control circuit requirements.

How many connection positions does the Finder 97.P2.7SMA have?

The Finder 97.P2.7SMA has eight connection positions, providing terminals for the coil and two changeover contact sets of a compatible Finder 46.52T relay.

What is the current and voltage rating of the Finder 97.P2.7SMA?

The socket is rated at 8 A and 250 V AC. The permissible switching load of the complete assembly also depends on the installed relay, the load type and the operating conditions.

Does the Finder 97.P2.7SMA use screw or push-in terminals?

The Finder 97.P2.7SMA uses screwless push-in spring terminals. Suitable conductors can be connected without conventional terminal screw tightening, following the manufacturer's wiring instructions.

What does SMA mean in the Finder 97.P2.7SMA part number?

The SMA packaging configuration indicates that the socket is supplied with a Finder 097.71 metal retaining clip, which helps hold the installed relay securely in position.

Is the Finder 97.P2.7SMA suitable for railway applications?

Yes. The Finder 97.P2.7SMA is designed for compatible railway relay installations and complies with specified requirements of EN 45545-2:2020, EN 61373 and EN 50155, covering material fire protection, vibration and shock resistance, and railway environmental conditions.

Can the Finder 97.P2.7SMA be mounted on a DIN rail?

Yes. The socket supports 35 mm DIN rail mounting in accordance with EN 60715 and can also be panel mounted in a suitable installation.

What conductor sizes can be used with the Finder 97.P2.7SMA?

The socket accepts solid and stranded conductors from 0.5 mm², with a maximum connection capacity of 1 × 2.5 mm² or 2 × 1.5 mm². Finder specifies an 8 mm conductor stripping length.

What is the operating temperature range of the Finder 97.P2.7SMA?

The socket has a specified ambient operating temperature range of -40 to +70 °C and an IP20 protection rating. It should be installed in an enclosure appropriate for the equipment and environment.

Can the Finder 97.P2.7SMA be used with timer modules and jumper links?

Yes. The socket supports compatible Finder 86.30T timer modules and selected Finder 097.52 and 097.42 2-way jumper links. Accessory compatibility and circuit ratings should be checked before installation.

Does the Finder 97.P2.7SMA include the relay?

No. The Finder 97.P2.7SMA is a relay socket supplied with a metal retaining clip. The compatible Finder 46.52T relay must be selected separately according to the required coil voltage and switching characteristics.

Trusted by Railway Electrical Engineers and Industrial Control Specialists

The Finder 97.P2.7SMA combines an eight-position push-in connection interface, an 8 A current rating, a metal retaining clip and railway-specific compliance characteristics to support dependable Finder 46.52T relay installations in rolling stock, electrical control panels and demanding industrial environments.