Finder 97.P1SMA is a blue five-pin industrial relay socket with screwless push-in terminals, 10 A and 250 V AC socket ratings, 35 mm DIN rail or panel mounting and an included 097.71 metal retaining clip for compatible Finder 46.61 relays.
£4.21
The Finder 97.P1SMA is a 5-pin, single-pole industrial relay socket designed for compatible Finder 46.61 electromechanical relays. Part of the Finder 97 Series, it combines screwless push-in terminal technology, a compact blue housing and a metal retaining clip to provide a practical relay connection solution for industrial automation and electrical control panels.
With rated socket values of 10 A at 250 V AC, the Finder 97.P1SMA is suitable for appropriately rated auxiliary switching and control circuits. Its 35 mm DIN rail or panel mounting arrangement provides installation flexibility, while the push-in terminals help reduce wiring time compared with conventional screw terminal connections.
The SMA configuration includes the Finder 097.71 metal retaining clip, which helps secure the installed relay in position. The socket also supports selected Finder 99.02 indication and EMC suppression modules, Finder 86.30 timer modules and compatible jumper links, making it a versatile interface for professional control panel assemblies.
The Finder 97.P1SMA provides the electrical and mechanical interface between a compatible Finder 46.61 plug-in relay and the external control circuit. Its five connection positions accommodate the relay coil and single-changeover contact terminals, allowing the installed relay to perform its specified switching function.
The screwless push-in terminal system enables suitable conductors to be connected without conventional terminal tightening screws. The socket can be installed on a standard 35 mm DIN rail or mounted directly onto a suitable panel, making it useful for both new equipment assembly and replacement applications.
The supplied Finder 097.71 metal retaining clip helps secure the relay within the socket. Because the relay is removable, maintenance personnel can replace a compatible relay without dismantling the fixed terminal wiring, provided the electrical circuit has first been safely isolated.
Optional Finder 99.02 Series modules can provide indication or EMC suppression, while compatible 86.30 timer modules can add timing functions to suitable relay assemblies. Finder 097.42 and 097.52 two-way jumper links provide additional wiring flexibility.
The socket itself does not independently switch electrical loads or determine the relay coil voltage. These characteristics depend on the installed Finder 46.61 relay. The complete assembly must remain within the electrical ratings of both the relay and socket.
Tick the specs you need, then view products that match.
| Device Type | Relay Socket | |
|---|---|---|
| Mounting Type | DIN rail, Panel | |
| Manufacturer | Finder | |
| Series | 97 Series | |
| Product code | 97.P1SMA | |
| Alternative ordering reference | 97P1SMA | |
| Product type | Industrial relay socket | |
| Socket configuration | Single-pole | |
| Number of relay connection positions | 5 | |
| Compatible relay family | Finder 46 Series | |
| Compatible relay type | Finder 46.61 | |
| Supported contact arrangement | 1 changeover contact (1 CO / SPDT) | |
| Rated socket current | 10 A | |
| Rated socket voltage | 250 V AC | |
| Terminal technology | Screwless push-in terminals | |
| Mounting method | DIN rail or panel mounting | |
| DIN rail size | 35 mm | |
| DIN rail standard | EN 60715 | |
| Housing width | 15.8 mm | |
| Housing height | 95.5 mm | |
| Housing depth | 65.7 mm | |
| Impulse withstand voltage between coil and contacts | 6 kV (1.2/50 µs) | |
| Protection category | IP20 | |
| Ambient temperature range | -40 to +70 °C | |
| Conductor stripping length | 8 mm | |
| Minimum solid conductor cross-section | 0.5 mm² | |
| Minimum stranded conductor cross-section | 0.5 mm² | |
| Maximum solid conductor cross-section | 1 × 2.5 mm² or 2 × 1.5 mm² | |
| Maximum stranded conductor cross-section | 1 × 2.5 mm² or 2 × 1.5 mm² | |
| Included retaining clip | Finder 097.71 metal retaining clip | |
| Compatible two-way jumper links | Finder 097.42 and 097.52 | |
| Compatible indication and suppression modules | Finder 99.02 Series | |
| Compatible timer modules | Finder 86.30 Series | |
| Marker tag holder | Finder 097.00 | |
| Housing colour | Blue | |
| EAN | 8012823401515 | |
| Product category | Relay Sockets and Accessories |
The Finder 97.P1SMA is a five-pin, single-pole industrial relay socket used to mount and electrically connect compatible Finder 46.61 relays in electrical control panels.
The socket is designed for the Finder 46.61 single-changeover relay. The selected relay must also meet the electrical requirements of the application.
The socket has a 5-pin relay connection interface, providing connections for the relay coil and one changeover contact.
No. The socket uses screwless push-in terminals, allowing suitable conductors to be connected without conventional terminal tightening screws.
Yes. The socket supports 35 mm DIN rail mounting in accordance with EN 60715 and can also be mounted directly onto a suitable panel.
Yes. The SMA configuration includes the Finder 097.71 metal retaining clip, which helps secure the compatible relay in the socket.
The socket has rated values of 10 A and 250 V AC. The installed relay and connected load must also comply with their respective electrical ratings.
No. The product is a relay socket supplied with a metal retaining clip. A compatible Finder 46.61 relay must be selected separately.
The basic socket does not incorporate an LED indicator. Compatible Finder 99.02 Series modules can be selected separately where coil indication or EMC suppression is required.
Yes. The socket supports compatible Finder 86.30 timer modules, subject to the manufacturer's relay and module compatibility requirements.
The push-in terminals accept specified solid or stranded conductors from 0.5 mm² up to 2.5 mm² for a single conductor, or two conductors of up to 1.5 mm² each. Finder specifies an 8 mm conductor stripping length.
The socket has an IP20 protection category and should be installed within an appropriately protected electrical enclosure.
Yes. The socket supports compatible Finder 097.42 and 097.52 two-way jumper links for suitable common-potential wiring arrangements.
Both are Finder 97 Series push-in relay sockets for compatible Finder 46.61 relays. The 97.P1SMA includes a metal retaining clip, while the 97.P1SPA includes a plastic retaining and release clip.
The 97.P1SMA is designed for compatible Finder 46.61 single-changeover relays, whereas the 97.P2SMA is designed for compatible Finder 46.52 double-changeover relays. Their connection arrangements differ, so they are not interchangeable.
Yes. The plug-in arrangement allows a compatible relay to be removed without disconnecting the fixed socket wiring. The electrical circuit must be safely isolated before replacement.
Finder 97 Series relay sockets provide reliable, service-friendly connection solutions for industrial automation and control equipment. The Finder 97.P1SMA combines compatibility with Finder 46.61 relays, screwless push-in terminals, 10 A / 250 V AC socket ratings, DIN rail or panel mounting and an included 097.71 metal retaining clip, making it a practical choice for electrical panel builders, automation engineers, OEM equipment manufacturers and industrial maintenance teams.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.