Finder 93.01.8.240 is a 230 V AC slimline DIN rail relay socket for compatible Finder 34 Series relays, featuring a five-pin connection, 6.2 mm-wide blue housing, screw terminals, integrated LED indication, EMC suppression and a relay retaining and extraction lever.
£9.33
The Finder 93.01.8.240 is a professional 230 V AC DIN rail relay socket designed for use with compatible Finder 34 Series miniature relays. Part of the Finder 93 Series, this compact interface socket combines convenient relay mounting, secure electrical connections and integrated indication and suppression circuitry in a slimline housing.
Featuring a 6.2 mm-wide blue housing, five-pin relay connection, screw terminals and a built-in LED indication and EMC suppression circuit, the Finder 93.01.8.240 is particularly suitable for industrial automation, PLC interface circuits, electrical control cabinets and machinery control systems.
The socket is designed for a 230 V AC nominal control supply and supports compatible Finder 34.51 relay arrangements. Its integrated retaining and extraction lever makes relay installation and replacement straightforward, helping simplify maintenance in densely populated electrical panels.
Important: The Finder 93.01.8.240 is a relay socket, not a complete switching relay. A suitable relay must be installed separately, and the current rating of the completed assembly depends on both the socket and the selected relay.
The Finder 93.01.8.240 provides the mechanical and electrical interface between a compatible Finder miniature relay and the external control wiring.
During installation, the socket is mounted onto a suitable 35 mm DIN rail. The control supply and output circuit conductors are connected to the socket's screw terminals. A compatible Finder 34 Series relay is then inserted into the five-pin socket connection.
When the relay coil receives its specified control voltage, the relay changes the state of its switching contacts. The socket provides the connections between those relay contacts and the external electrical circuit.
The socket's integrated LED indication circuit provides a convenient visual reference when the coil control circuit is energised. This can help engineers identify active control signals during commissioning and troubleshooting.
The integrated EMC suppression circuit helps manage switching disturbances associated with the relay coil. This is particularly useful in automation systems where electronic controllers, PLCs and other sensitive components are installed nearby.
The actual contact arrangement and electrical switching characteristics depend on the fitted relay. The socket itself does not provide independent switching contacts.
A key advantage of the Finder 93.01.8.240 is its integrated combination of LED indication and electromagnetic compatibility suppression.
When an electromechanical relay coil is switched, the changing magnetic field can generate an electrical transient. If not adequately managed, such disturbances may interfere with nearby electronic equipment.
The suppression circuit incorporated into the socket helps reduce these unwanted effects. This can simplify panel construction by avoiding the need to install a separate external suppression component in suitable applications.
The LED indication feature also assists maintenance technicians by providing an immediate visual reference for the coil control circuit.
Important: The LED indicates the state of the associated control circuit; it does not prove that the relay contacts have operated correctly or that the connected load is energised. Electrical testing should be used where confirmation is required.
The Finder 93.01.8.240 is designed for 230 V AC nominal control circuits. The manufacturer socket selection information identifies the 93.01.8.240 version for 220–240 V AC applications.
This distinction is important because the Finder 93 Series includes other socket variants intended for different control voltages and DC supplies.
The 93.01.8.240 should not be treated as a universal AC/DC socket. For DC control supplies, the appropriate DC-rated socket variant must be selected.
For example, the Finder 93.01.7.060 is associated with 48–60 V DC control circuits, whereas the 93.01.8.240 is intended for 230 V AC applications.
Correct matching of the socket, relay coil voltage and supply type is essential to ensure proper operation and avoid damage to the indication and suppression circuitry.
The Finder 93.01.8.240 features an exceptionally narrow 6.2 mm-wide housing, allowing multiple relay interface assemblies to be installed side by side on a DIN rail.
This compact construction is particularly useful in industrial control cabinets where numerous PLC signals, auxiliary control circuits or individual switching channels must be accommodated within a limited space.
The blue housing provides a distinctive visual appearance, while the retaining and extraction lever helps keep the relay securely installed.
The modular socket arrangement also simplifies servicing. A compatible relay can be removed and replaced without disturbing the external wiring, provided the electrical circuit has first been safely isolated.
The Finder 93.01.8.240 is designed for installation on a standard 35 mm DIN rail. Its screw terminal connections provide a conventional wiring method for electrical engineers and industrial control panel builders.
The socket is intended for use with compatible Finder 34 Series relays. The exact relay should be selected according to the required coil voltage, switching current, contact configuration and application requirements.
For a typical installation, the socket is secured to the DIN rail, the control and load wiring is connected to the appropriate terminals, and the compatible relay is inserted and secured using the retaining lever.
The manufacturer's wiring diagram must be followed to identify the correct coil and contact terminal connections. The socket should be installed inside a suitable electrical enclosure with appropriate circuit protection.
Safety note: The 93.01.8.240 is intended for mains-voltage AC control circuits. Installation, testing and maintenance must be carried out by competent personnel using appropriate safe isolation procedures.
The Finder 93 Series includes several relay socket variants designed for different control voltages and electrical connection requirements.
When replacing an existing relay socket, check the control supply type, relay compatibility, wiring arrangement and suppression circuit characteristics before selecting a substitute.
Tick the specs you need, then view products that match.
| Device Type | Relay Socket | |
|---|---|---|
| Mounting Type | DIN rail | |
| Manufacturer | Finder | |
| Product series | 93 | |
| Manufacturer part number | 93.01.8.240 | |
| Alternative part number | 93018240 | |
| Product type | Electromechanical relay socket | |
| Socket type | Slimline DIN rail relay interface socket | |
| Nominal operating voltage | 230 V AC | |
| Associated AC voltage range | 220–240 V AC | |
| Control supply type | Alternating current only | |
| Relay connection positions | 5 | |
| Compatible relay family | Finder 34 Series | |
| Primary compatible relay | Finder 34.51 | |
| Additional relay compatibility | Selected Finder 34.81 variants, subject to verification | |
| Integrated coil indication | LED | |
| Integrated suppression | EMC suppression circuit | |
| Relay retaining mechanism | Retaining and extraction lever | |
| Electrical terminal type | Screw terminals | |
| Mounting method | DIN rail | |
| DIN rail size | 35 mm | |
| Housing colour | Blue | |
| Housing width | 6.2 mm | |
| Housing height | Approximately 75.6 mm | |
| Housing depth | Approximately 87.9 mm | |
| Dimensions (W × H × D) | Approximately 6.2 × 75.6 × 87.9 mm | |
| Approximate product weight | 26 g | |
| Integrated switching contacts | None; provided by the fitted relay | |
| Switching current capacity | Determined by the compatible relay and socket assembly ratings | |
| Safe separation reference | VDE 0106 Part 101 | |
| RoHS status | RoHS3 compliant | |
| REACH status | REACH unaffected, according to distributor information | |
| EAN / GTIN-13 | 8012823264998 | |
| Typical applications | PLC interfaces, machinery control panels, automation cabinets and industrial relay switching systems |
The Finder 93.01.8.240 is a slimline DIN rail relay socket used with compatible Finder 34 Series relays. It provides electrical connections, relay retention, LED indication and EMC suppression for industrial control applications.
No. It is a relay socket, not a complete switching relay. A compatible Finder relay must be purchased and installed separately.
The socket's integrated indication and suppression circuit is designed for a 230 V AC nominal supply, with the manufacturer selection information identifying the 220–240 V AC range.
No. This version is intended for AC control circuits. A suitable DC-rated Finder socket variant should be selected for DC relay applications.
The socket is designed for compatible Finder 34.51 relays. Some supplier documentation also references selected 34.81 variants. Exact compatibility should be checked against the current Finder relay/socket selection information.
The socket has five relay connection positions.
Yes. It includes an integrated LED indication circuit to provide visual information about the associated relay control circuit.
Yes. The socket incorporates an EMC suppression circuit designed to help reduce electrical disturbances associated with relay coil switching.
The housing is just 6.2 mm wide, making it suitable for compact, high-density relay interface assemblies.
Yes. The socket is designed for installation on a standard 35 mm DIN rail.
Yes. The socket uses screw terminal connections for external control and switching circuit wiring.
The lever helps secure the relay within the socket and assists with removal when a compatible relay needs to be replaced.
The 93.01.8.240 is intended for 230 V AC control circuits, while the 93.01.7.060 is associated with 48–60 V DC control circuits. Both are slimline screw terminal relay sockets with integrated indication and suppression.
DigiKey lists the 93.01.8.240 as a manufacturer-recommended substitute for the obsolete 93.01.0.240. The complete relay assembly and supply requirements should still be checked before replacement.
No. The switching contacts are provided by the compatible relay installed in the socket. The socket itself does not operate as an independent switching relay.
Yes. Its compact construction, LED indication, EMC suppression and removable relay arrangement make it suitable for appropriately designed PLC and industrial automation interface circuits.
The Finder 93.01.8.240 combines a 230 V AC indication and suppression circuit, five-pin relay connection, integrated LED and EMC suppression, screw terminals and a retaining and extraction lever in a slim 6.2 mm DIN rail housing. Designed for compatible Finder 34 Series relays, it provides a compact, maintainable interface solution for industrial control cabinets, PLC switching systems and machinery automation.
For manufacturer relay compatibility tables, wiring diagrams and installation requirements, refer to the Finder 93 Series sockets and accessories datasheet.
Technical note: This socket is intended for AC control circuits. Verify the exact relay, control voltage, switching ratings and wiring arrangement against current Finder documentation before installation.