Finder 7S.63.9.110.0211 is a 110 V DC modular safety relay with 6 A forcibly guided contacts, two normally open safety contacts, one normally closed feedback contact and an auxiliary signalling contact, designed for DIN rail installation in industrial machinery safety and automation systems.
£87.78
The Finder 7S.63.9.110.0211 is a high-performance 110 V DC modular safety relay with forcibly guided contacts, designed for dependable safety-related switching and monitoring in industrial machinery and automation systems. As part of the Finder 7S Series safety relay range, it is engineered for machine builders, electrical control panel manufacturers and industrial automation engineers requiring reliable switching components for functional safety applications.
This safety relay features two normally open (NO) safety contacts, one normally closed (NC) feedback contact and one auxiliary signalling contact. Its double-channel architecture (1oo2) supports safety-related control circuits, while the forcibly guided contact arrangement enables external monitoring systems to detect certain contact failures. An integrated LED coil status indicator provides convenient visual diagnostics, and screw terminals ensure secure electrical connections.
With a 110 V DC nominal coil voltage, 6 A rated contact current and 250 V AC nominal contact voltage, the Finder 7S.63.9.110.0211 is suitable for machinery safety circuits, industrial automation equipment, lifting systems and process control installations. Its compact 22.5 mm-wide DIN rail mounting design allows straightforward integration into electrical control panels and industrial cabinets.
Safety relays such as the Finder 7S.63.9.110.0211 provide electrically operated switching with forcibly guided contacts that support the monitoring of safety-related circuits. Unlike conventional relays, forcibly guided contact arrangements are mechanically designed to prevent associated normally open and normally closed contacts from being closed simultaneously under specified fault conditions. This allows external monitoring circuits to detect certain failures, including welded contacts, helping improve the diagnostic capability of industrial safety systems.
The Finder 7S.63.9.110.0211 incorporates a double-channel 1oo2 architecture with two normally open safety contacts, one normally closed feedback contact and an auxiliary signalling contact. This configuration supports integration into appropriately designed safety control circuits used in automated machinery, lifting equipment, industrial processing systems and other safety-related installations.
The Finder 7S.63 Series is developed for functional safety applications where reliable contact switching and monitoring are essential. Its forcibly guided contact arrangement supports the design of safety systems targeting Safety Integrity Level 3 (SIL 3) and Performance Level e (PL e). The achievable safety rating depends on the complete system architecture, diagnostic coverage, external monitoring and validation of the finished installation.
The relay's 110 V DC coil supply, integrated LED indication and secure screw terminals simplify integration into industrial control equipment. Its compact DIN rail format makes it suitable for electrical panels where dependable switching, accessibility and efficient use of cabinet space are important.
Tick the specs you need, then view products that match.
| Device Type | Positively Guided Relay | |
|---|---|---|
| Terminal Type | Screw | |
| Mounting Type | DIN rail | |
| Switching Current (A) | 6 A | |
| Manufacturer | Finder | |
| Series | 7S Series Modular Safety Relays | |
| Model | 7S.63.9.110.0211 | |
| Product type | Modular safety relay with forcibly guided contacts | |
| Nominal coil voltage | 110 V DC | |
| Coil type | DC | |
| Rated coil power | 1.7 W | |
| Coil resistance | 5.5 kΩ | |
| Coil operating voltage range | 93.5–121 V DC | |
| Contact configuration | 2 NO + 1 NC | |
| Safety contacts | 2 normally open (NO) | |
| Feedback contacts | 1 normally closed (NC) | |
| Auxiliary contacts | 1 signalling contact | |
| Rated contact current | 6 A | |
| Nominal contact voltage | 250 V AC | |
| Contact materials | Silver tin oxide (AgSnO2) and silver nickel gold (AgNi + Au) | |
| Contact guidance | Forcibly guided contacts | |
| Safety architecture | Double-channel (1oo2) | |
| Functional safety capability | Up to SIL 3 / PL e when correctly integrated into a validated safety system | |
| Functional safety standards | IEC 61508 and EN ISO 13849-1 | |
| Contact operation time | 10 ms | |
| Contact release time | 7 ms | |
| Mechanical life | 10 million cycles | |
| Electrical life | 100,000 cycles under specified load conditions | |
| Operating temperature | -40 to +70 °C | |
| Protection rating | IP20 | |
| Mounting type | 35 mm DIN rail (EN 60715) | |
| Terminal type | Screw terminals | |
| Module width | 22.5 mm | |
| Dimensions (W × H × D) | approx. 22.5 × 86.2 × 96 mm | |
| Weight | approx. 0.117 kg | |
| Status indication | Integrated LED coil indicator | |
| Country of origin | Italy | |
| Environmental compliance | RoHS compliant |
The Finder 7S.63.9.110.0211 is a modular safety relay designed for safety-related switching and monitoring in industrial machinery and automation systems. It is commonly integrated into emergency stop circuits, machine guarding systems, lifting equipment, railway applications and industrial safety control installations.
The relay operates with a 110 V DC nominal coil supply. Its specified operating voltage range is approximately 93.5–121 V DC, making it suitable for compatible industrial DC control circuits.
The Finder 7S.63.9.110.0211 features two normally open safety contacts, one normally closed feedback contact and one auxiliary signalling contact. This arrangement supports safety-related switching, external contact monitoring and operational status indication.
The relay has a 6 A rated contact current and a 250 V AC nominal contact voltage. The permissible switching load depends on the electrical load category and operating conditions.
Yes. The Finder 7S.63.9.110.0211 is designed for integration into functional safety systems targeting SIL 3 and PL e. Achieving these levels requires suitable circuit architecture, diagnostic monitoring, correct installation and system validation. The relay alone does not establish the safety rating of a complete machine.
Forcibly guided contacts are mechanically linked relay contacts designed to prevent associated normally open and normally closed contacts from being closed simultaneously under specified fault conditions. This enables external monitoring circuits to detect certain contact failures, such as welded contacts, and supports fault detection in industrial safety systems.
Yes. The relay includes an integrated LED coil status indicator that provides visual confirmation of coil energisation, helping engineers with commissioning, maintenance and troubleshooting.
The relay is designed for installation on a 35 mm DIN rail inside industrial electrical control panels and machinery cabinets. It features a compact 22.5 mm module width, screw terminals and an IP20 protection rating.
Finder 7S Series safety relays are designed to deliver dependable forcibly guided contact switching for industrial machinery and functional safety applications. The Finder 7S.63.9.110.0211 combines a 110 V DC coil, 6 A contact rating, double-channel safety architecture and compact DIN rail construction, providing a reliable switching component for engineers developing industrial safety and automation control systems.