Finder 7S.63.9.048.0211 is a 48 V DC modular safety relay with 6 A forcibly guided contacts, two normally open safety contacts, one normally closed feedback contact and an auxiliary signalling contact, designed for DIN rail installation in industrial machinery safety and automation systems.
£76.13
The Finder 7S.63.9.048.0211 is a reliable, industrial-grade 48 V DC safety relay with forcibly guided contacts, designed for safety-related switching and monitoring applications in industrial machinery and automation systems. As part of the Finder 7S Series modular safety relays, it provides dependable contact operation for machine builders, control panel manufacturers and industrial automation engineers requiring reliable functional safety components.
This safety relay features two normally open (NO) safety contacts, one normally closed (NC) feedback contact and one auxiliary signalling contact. Its double-channel architecture (1oo2) supports safety-related control circuits, while its forcibly guided contact design helps enable reliable contact-state monitoring and fault detection. The relay incorporates an LED coil status indicator for convenient visual diagnostics and screw terminals for secure electrical connections.
With a 48 V DC nominal coil voltage, 6 A rated switching current and 250 V AC rated switching voltage, the Finder 7S.63.9.048.0211 is suitable for industrial safety circuits, machinery control systems, lifting equipment and automated production installations. Its compact 22.5 mm-wide DIN rail mounting format allows straightforward integration into electrical control cabinets and industrial automation panels.
Safety relays such as the Finder 7S.63.9.048.0211 provide electrically operated switching with forcibly guided contacts that support the monitoring of safety-related circuits. Unlike conventional relays, forcibly guided contact arrangements are mechanically designed to prevent associated normally open and normally closed contacts from being closed simultaneously under specified fault conditions. This enables external monitoring circuits to identify certain contact faults and helps improve the diagnostic capability of industrial safety systems.
The Finder 7S.63.9.048.0211 uses a double-channel 1oo2 contact architecture with two normally open safety contacts, a normally closed feedback contact and an auxiliary signalling contact. This configuration makes it suitable for use within appropriately designed safety control systems for machinery, lifting equipment and automated industrial processes.
The Finder 7S.63 Series is designed for functional safety applications requiring reliable contact switching and monitoring. Its forcibly guided contact arrangement supports integration into systems targeting Safety Integrity Level 3 (SIL 3) and Performance Level e (PL e). The achievable safety level depends on the complete circuit architecture, external monitoring, diagnostic coverage and validation of the finished installation.
The relay's 48 V DC coil, LED status indicator and screw terminal connections make it straightforward to incorporate into industrial electrical panels. Its DIN rail mounting design also supports convenient replacement and maintenance within appropriately protected control enclosures.
Tick the specs you need, then view products that match.
| Device Type | Positively Guided Relay | |
|---|---|---|
| Terminal Type | Screw | |
| Switching Current (A) | 6 A | |
| Load Voltage | 250 V AC | |
| Mounting Type | DIN rail | |
| Manufacturer | Finder | |
| Series | 7S Series Modular Safety Relays | |
| Model | 7S.63.9.048.0211 | |
| Product type | Modular safety relay with forcibly guided contacts | |
| Nominal coil voltage | 48 V DC | |
| Coil type | DC | |
| Rated coil power | 1.7 W | |
| Coil operating range | 0.85–1.1 × nominal voltage | |
| Contact configuration | 2 NO + 1 NC + 1 auxiliary signalling contact | |
| Safety contacts | 2 normally open (NO) | |
| Feedback contacts | 1 normally closed (NC) | |
| Auxiliary contacts | 1 signalling contact | |
| Rated contact current | 6 A | |
| Maximum peak contact current | 15 A | |
| Rated switching voltage | 250 V AC | |
| Rated AC1 load | 1500 VA | |
| Rated AC15 current at 230 V AC | 5 A | |
| Contact materials | AgSnO2 and AgNi + Au | |
| Contact guidance | Class A forcibly guided contacts | |
| Safety architecture | Double-channel (1oo2) | |
| Functional safety capability | SIL 3 / PL e when correctly integrated into a validated safety system | |
| Safety contact standard | EN 61810-3 | |
| Functional safety standards | EN 61508, IEC 62061 and EN ISO 13849-1 | |
| NO contact operate / release time | 10 / 7 ms | |
| NC contact operate / release time | 5 / 30 ms | |
| Mechanical life | 10 million cycles | |
| Electrical life at rated AC1 load | 100,000 cycles | |
| Impulse withstand voltage between coil and contacts | 6 kV | |
| Dielectric strength between open contacts | 1500 V AC | |
| Operating temperature | -40 to +70 °C | |
| Protection rating | IP20 | |
| Mounting type | 35 mm DIN rail (EN 60715) | |
| Terminal type | Screw terminals | |
| Module width | 22.5 mm | |
| Status indication | Integrated LED coil indicator | |
| Country of origin | Italy | |
| Environmental compliance | RoHS compliant |
The Finder 7S.63.9.048.0211 is a modular safety relay designed for safety-related switching and monitoring in industrial machinery and automation systems. It is commonly integrated into emergency stop circuits, machine guarding systems, lifting equipment and industrial safety control installations.
The relay operates with a 48 V DC nominal coil supply. Its specified operating voltage range is 0.85–1.1 times the nominal coil voltage.
The Finder 7S.63.9.048.0211 features two normally open safety contacts, one normally closed feedback contact and one auxiliary signalling contact. This arrangement supports safety-related switching, contact monitoring and status indication.
The relay has a 6 A rated contact current and a 250 V AC rated switching voltage. The permissible switching load depends on the electrical load category and operating conditions.
Yes. The Finder 7S.63.9.048.0211 belongs to a safety relay range designed for integration into functional safety applications up to SIL 3 and PL e. Achieving these safety levels requires appropriate system architecture, monitoring, installation and validation. The relay alone does not establish the safety rating of a complete machine.
Forcibly guided contacts are mechanically linked relay contacts designed to prevent associated normally open and normally closed contacts from being closed simultaneously under specified fault conditions. This enables external safety monitoring circuits to detect certain contact failures, such as welded contacts.
Yes. The relay includes an integrated LED coil status indicator that provides visual confirmation of coil energisation, assisting with commissioning, maintenance and troubleshooting.
The relay is designed for installation on a 35 mm DIN rail inside industrial electrical control panels and machinery cabinets. It features a compact 22.5 mm module width, screw terminals and an IP20 protection rating.
Finder 7S Series safety relays provide dependable forcibly guided contact switching for industrial machinery and functional safety applications. The Finder 7S.63.9.048.0211 combines a 48 V DC coil, 6 A contact rating, double-channel safety architecture and compact DIN rail construction, making it a practical component for engineers designing reliable industrial safety and automation control systems.