Finder 7S.63.9.012.0211 is a 12 V DC force-guided safety relay module featuring 2 normally open and 1 normally closed contacts, an additional auxiliary signalling contact, a 6 A contact rating, 250 V AC nominal contact voltage, screw terminals, LED status indication and DIN rail mounting for industrial safety-related control applications.
£76.13
The Finder 7S.63.9.012.0211 is a professional 12 V DC force-guided safety relay module designed for industrial automation, machinery safety and monitored electrical control applications. Part of the Finder 7S Series, this relay features 2 normally open (NO) contacts, 1 normally closed (NC) contact and 1 auxiliary signalling contact, providing switching and feedback functionality for safety-related control systems.
Featuring a 6 A rated contact current, 250 V AC nominal contact voltage and 12 V DC operating coil, the Finder 7S.63.9.012.0211 combines electromagnetic switching with force-guided contact technology. Its mechanically linked contacts support the detection of certain relay failures, including welded contacts, when used with an appropriately designed external monitoring circuit.
The module is particularly suited to applications requiring dual-channel safety architectures, contact-state feedback and dependable switching. Its screw terminals, integrated LED coil-status indication and 35 mm DIN rail mounting simplify integration into industrial control cabinets. With a 22.5 mm housing width, IP20 protection and an operating temperature range of −40 to +70 °C, it offers a compact solution for demanding industrial environments.
The Finder 7S.63.9.012.0211 is intended for use in safety-related applications, including systems engineered for SIL 3 requirements. The relay itself does not independently establish a SIL rating or Performance Level; these depend on the design and validation of the complete safety function.
Modern industrial machinery requires control systems capable of switching electrical circuits reliably while identifying faults that could compromise a safety function. Conventional relays may not provide the contact relationship required for reliable fault monitoring. The Finder 7S.63.9.012.0211 addresses this requirement through its force-guided contact construction and dedicated signalling functionality.
The relay incorporates two normally open contacts for switching compatible control circuits and one normally closed contact that can support feedback monitoring. The mechanically linked contact construction prevents specified normally open and normally closed contacts from being closed simultaneously under defined fault conditions. This characteristic allows suitable external monitoring systems to detect certain faults, including contact welding.
An additional auxiliary signalling contact provides further flexibility for status indication and control-system integration. The precise role of each contact must be determined from the manufacturer's connection diagram, particularly where the auxiliary contact is used alongside safety-related circuits.
The 12 V DC operating coil makes the relay suitable for appropriately rated low-voltage control systems. Its 6 A rated contacts and 250 V AC nominal contact voltage support industrial switching applications where the electrical load remains within the manufacturer's specified limits. The load category, inrush current, switching frequency and operating conditions must be considered when designing the installation.
The relay is designed for applications where dual-channel safety architectures and external feedback monitoring may be required. Such arrangements can improve fault detection and system reliability when properly implemented. However, redundancy and diagnostic performance depend on the complete system architecture rather than the relay alone.
The integrated LED coil-status indicator provides useful visual information during commissioning and maintenance. Its screw terminals offer secure electrical connections, while the 22.5 mm DIN rail housing enables efficient installation alongside safety PLCs, monitoring devices, contactors and other industrial automation components.
Important safety consideration: Although the Finder 7S.63.9.012.0211 is intended for safety-related applications, including suitably engineered SIL 3 systems, it does not independently guarantee SIL 3, PL e or any other system-level safety classification. The complete safety function must be assessed, calculated and validated according to the applicable standards.
Tick the specs you need, then view products that match.
| Device Type | Positively Guided Relay | |
|---|---|---|
| Terminal Type | Screw | |
| Switching Current (A) | 6 A | |
| Mounting Type | DIN rail | |
| Manufacturer | Finder | |
| Series | 7S Series | |
| Product family | 7S.63 | |
| Model | 7S.63.9.012.0211 | |
| Manufacturer part number | 7S.63.9.012.0211 | |
| Alternative reference | 7S6390120211 | |
| Product type | Modular force-guided safety relay | |
| Relay technology | Electromagnetic | |
| Relay operation | Non-latching | |
| Main contact configuration | 2 NO + 1 NC | |
| Auxiliary signalling contacts | 1 | |
| Contact technology | Force-guided, mechanically linked | |
| Contact material | Silver tin oxide and gold-plated contact materials | |
| Rated contact current | 6 A | |
| Nominal AC contact voltage | 250 V AC | |
| Nominal coil voltage | 12 V DC | |
| Nominal coil power | 1 W | |
| Terminal type | Screw terminals | |
| Mounting | 35 mm DIN rail | |
| Housing width | 22.5 mm | |
| Ingress protection | IP20 | |
| Operating temperature | −40 to +70 °C | |
| Status indication | Integrated LED coil-status indicator | |
| Safety-related application | Monitored industrial safety control systems | |
| Safety architecture compatibility | Suitable for appropriately engineered dual-channel systems | |
| Compliance | RoHS | |
| Listed approvals | CE, cULus and EAC | |
| Country of origin | Italy |
The Finder 7S.63.9.012.0211 is a force-guided relay module designed for industrial automation and safety-related control systems requiring monitored switching, mechanically linked contacts and auxiliary signalling.
The relay has a 12 V DC coil with a nominal power consumption of approximately 1 W.
The Finder 7S.63.9.012.0211 has 2 normally open contacts, 1 normally closed contact and 1 additional auxiliary signalling contact.
The auxiliary contact provides an additional signalling function that can be used within compatible control and monitoring arrangements. Its electrical role and permitted use should be confirmed against the Finder connection diagram.
Force-guided contacts are mechanically linked normally open and normally closed contacts designed to prevent simultaneous closure under specified fault conditions. This enables suitable external monitoring circuits to detect certain relay contact failures.
The relay has a 6 A rated contact current. The permitted switching load depends on the operating voltage, load characteristics and manufacturer's electrical ratings.
The Finder 7S.63.9.012.0211 has a 250 V AC nominal contact voltage, subject to the applicable switching and load limitations.
Yes. The relay is intended for integration into appropriately engineered safety-related applications, including systems designed for SIL 3 requirements. The complete system must meet the applicable architecture, reliability, diagnostic and validation requirements.
No. A force-guided relay is one component within a safety-related control system. The achieved SIL or Performance Level depends on the complete system architecture, diagnostic coverage, component reliability and validation.
The relay uses screw terminals, providing conventional electrical connections for industrial control panel wiring.
Yes. The Finder 7S.63.9.012.0211 includes an integrated LED indicator that provides visual indication of coil energisation.
The relay is designed for installation on a standard 35 mm DIN rail inside a suitable electrical control enclosure.
The Finder 7S.63.9.012.0211 has a compact housing width of 22.5 mm, making it suitable for densely populated control cabinets.
The relay has an operating temperature range of −40 to +70 °C, supporting use in a wide range of protected industrial environments.
The 7S.63 family includes configurations with two normally open contacts, one normally closed contact and an additional auxiliary signalling contact, while the 7S.34 family offers four-contact force-guided configurations such as 2 NO + 2 NC or 3 NO + 1 NC. The exact contact arrangement, coil voltage and terminal configuration must be checked before substitution.
Yes. The Finder 7S.63.9.012.0211 can form part of a properly engineered emergency-stop system where its contact arrangement, switching ratings and monitoring characteristics meet the application's requirements. It is not a complete emergency-stop controller on its own.
Check the 12 V DC coil supply, 2 NO + 1 NC contact arrangement, auxiliary signalling contact, rated switching current, load voltage, safety monitoring requirements, screw-terminal wiring, environmental conditions and manufacturer's installation instructions.
Finder 7S Series force-guided relays provide dependable switching and contact-state monitoring capabilities for industrial automation and safety-related electrical control systems. Combining a 12 V DC coil, 2 NO + 1 NC force-guided contacts, an additional auxiliary signalling contact, a 6 A contact rating, screw terminals, LED status indication and compact DIN rail construction, the Finder 7S.63.9.012.0211 offers a practical solution for professionally engineered machinery safety and monitoring applications.