Finder 7S.43.9.012.0211 is a DIN rail mounted modular safety relay with a 12 V DC coil, 6 A rated forcibly guided 2 NO + 1 NC contacts, screwless terminals and LED indication for industrial machinery safety and automation control circuits.
£76.13
The Finder 7S.43.9.012.0211 is a compact and reliable modular safety relay with forcibly guided contacts designed for industrial machinery safety, electrical control panels and automation systems. As part of the Finder 7S Series, this relay provides dependable electromechanical switching and contact monitoring for safety-related control applications requiring reliable operation and fault detection.
Featuring two normally open (NO) contacts and one normally closed (NC) auxiliary signalling contact, the relay incorporates mechanically linked contacts designed to support fault detection in appropriately engineered safety circuits. Its double-channel architecture (1oo2), compact DIN rail housing, screwless terminal connections and integrated LED status indicator make it suitable for industrial safety systems where reliable switching and monitoring are essential.
With a 12 V DC nominal coil voltage, 6 A contact current rating and 250 V AC nominal switching voltage, the Finder 7S.43.9.012.0211 provides a practical switching solution for industrial safety interfaces, machinery control circuits and automation equipment. Its 22.5 mm wide housing and operating temperature range of -40 to +70 °C support compact installation and dependable operation in demanding industrial environments.
Safety relays with forcibly guided contacts are essential components in many industrial machine safety and monitoring circuits. The Finder 7S.43.9.012.0211 incorporates a mechanically linked contact arrangement designed so that normally open and normally closed contacts cannot simultaneously remain closed under specified fault conditions. This characteristic enables external monitoring circuits to detect certain contact failures, helping engineers design dependable safety-related control systems.
The Finder 7S Series is developed for safety-related industrial applications including machinery control, lifts, hoists, cranes, escalators and process automation equipment. The 7S.43.9.012.0211 combines a 12 V DC coil, two normally open switching contacts, one normally closed auxiliary contact and compact DIN rail construction. Its forcibly guided contacts can contribute to safety functions designed for demanding performance requirements when incorporated into a properly engineered, monitored and validated safety system. The relay itself is a safety-related component and does not independently establish the safety integrity level or performance level of the complete installation.
Tick the specs you need, then view products that match.
| Device Type | Positively Guided Relay | |
|---|---|---|
| Terminal Type | Spring clamp | |
| Mounting Type | DIN rail | |
| Switching Current (A) | 6 A | |
| Manufacturer | Finder | |
| Series | 7S Series | |
| Model | 7S.43.9.012.0211 | |
| Product type | Modular safety relay with forcibly guided contacts | |
| Relay operation | Electromechanical, non-latching | |
| Nominal coil voltage | 12 V DC | |
| Coil supply type | DC | |
| Contact configuration | 2 NO + 1 NC | |
| Number of contacts | 3 | |
| Safety-related normally open contacts | 2 | |
| Auxiliary signalling contacts | 1 NC | |
| Contact current rating | 6 A | |
| Nominal switching voltage | 250 V AC | |
| Rated switching capacity | 1,500 VA | |
| Coil power consumption | 1.3 W | |
| Nominal coil current | 105 mA | |
| Coil resistance | 114.3 Ω | |
| Must-operate voltage | 10.2 V DC | |
| Must-release voltage | 1.2 V DC | |
| Operate time | 10 ms | |
| Release time | 7 ms | |
| Contact material | Silver tin oxide (AgSnO), silver nickel (AgNi) and gold (Au) | |
| Contact arrangement | Forcibly guided contacts | |
| Contact guidance classification | Type A | |
| Safety architecture | Double-channel (1oo2) | |
| Protection rating | IP20 | |
| Mounting type | 35 mm DIN rail | |
| Mounting standard | EN 60715 | |
| Terminal type | Screwless spring-clamp terminals | |
| Status indication | Integrated LED | |
| Housing width | 22.5 mm | |
| Operating temperature | -40 to +70 °C | |
| Contact standard | EN 61810-3 | |
| Country of origin | Italy |
The Finder 7S.43.9.012.0211 is a modular safety relay designed for switching and contact monitoring in industrial machinery safety and automation control systems. Its forcibly guided contacts support fault detection in appropriately designed safety-related electrical circuits.
The relay uses a 12 V DC nominal coil and is intended for compatible low-voltage DC control circuits. The coil supply must be matched to the manufacturer's specified operating voltage range.
The Finder 7S.43.9.012.0211 features two normally open (NO) contacts and one normally closed (NC) auxiliary signalling contact. Its three contacts are forcibly guided to support reliable switching and contact monitoring.
The relay has a 6 A contact current rating and a nominal switching voltage of 250 V AC. Actual permissible switching loads depend on the load category, voltage and operating conditions.
Forcibly guided contacts are mechanically linked relay contacts designed to prevent normally open and normally closed contacts from simultaneously occupying the closed position under specified fault conditions. This enables suitable external monitoring circuits to detect certain failures, such as welded contacts.
The relay is designed for 35 mm DIN rail mounting inside electrical control panels. It features a compact 22.5 mm wide housing and screwless spring-clamp terminals for electrical connections.
Yes. The Finder 7S.43.9.012.0211 includes an integrated LED status indicator that provides visual indication of relay coil energisation, assisting with commissioning, maintenance and troubleshooting.
The relay is specified for operation between -40 and +70 °C, making it suitable for a wide range of industrial electrical control environments when installed according to the manufacturer's requirements.
Yes. The relay can be incorporated into compatible safety PLC output and feedback circuits. Its forcibly guided contacts support external device monitoring, although the overall safety function must be designed and validated to meet the required performance level.
No. The Finder 7S.43.9.012.0211 is an electromechanical relay with forcibly guided contacts, not a complete standalone safety controller. It must be integrated with suitable monitoring, diagnostic and control circuitry to achieve the required machinery safety function.
Finder 7S Series safety relays are designed to provide dependable electromechanical switching and contact monitoring for industrial machinery safety applications. The Finder 7S.43.9.012.0211 combines a 12 V DC coil, 6 A contact rating, 2 NO + 1 NC forcibly guided contact configuration, screwless terminals and compact DIN rail construction, making it a practical choice for machine builders, electrical panel manufacturers and industrial control engineers designing reliable safety-related systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.