Finder 7S.14.9.048.4310 is a 48 V DC DIN rail-mounted relay module with Class A forcibly guided contacts, 3 NO + 1 NC contact configuration, 6 A rated current per contact, 250 V AC rated switching voltage, screwless spring-clamp terminals and integrated LED indication for industrial safety-related control systems.
£72.77
The Finder 7S.14.9.048.4310 is a professional 48 V DC safety relay module with Class A forcibly guided contacts, designed for industrial machinery, automation equipment and safety-related electrical control systems. Part of the Finder Series 7S, this compact DIN rail-mounted relay features a 3 normally open (NO) + 1 normally closed (NC) contact configuration, providing three switching contacts and one mechanically linked feedback contact.
With a 6 A rated current per contact, 250 V AC rated switching voltage and 48 V DC operating coil, the Finder 7S.14.9.048.4310 is designed for applications requiring dependable relay switching and contact monitoring. Its forcibly guided contact arrangement complies with EN 61810-3, supporting the detection of certain contact faults within correctly designed safety circuits.
The module incorporates screwless spring-clamp terminals, an integrated LED coil status indicator and a compact 22.5 mm DIN rail housing. Its industrial construction and four-contact arrangement make it particularly suitable for machinery safety interfaces, monitored switching circuits and safety relay expansion applications.
The key characteristic of the Finder 7S.14.9.048.4310 is its Class A forcibly guided contact arrangement. Unlike conventional relays, the normally open and normally closed contacts are mechanically linked to prevent them from simultaneously reaching their closed positions under specified fault conditions.
This construction allows appropriately designed monitoring circuits to identify certain contact faults. For example, if a normally open contact becomes welded closed, the mechanically linked normally closed contact cannot return to its normal closed position. A suitable monitoring device can detect this condition and respond according to the safety system design.
The 3 NO + 1 NC configuration provides three normally open contacts for controlled switching functions and one normally closed contact that can be incorporated into a feedback or monitoring circuit. This makes the relay useful in applications requiring multiple controlled outputs alongside contact status monitoring.
The Finder 7S.14.9.048.4310 uses Type A forcibly guided contact technology in accordance with EN 61810-3. This supports its use as a component in safety-related control systems designed and validated according to applicable machinery and functional safety standards.
Important: A forcibly guided relay is not a complete safety controller. The relay must be integrated into a suitable circuit architecture with the necessary monitoring, diagnostics and protective measures to achieve the required safety performance.
The Finder 7S.14.9.048.4310 operates from a 48 V DC nominal coil supply, making it suitable for industrial control systems that use this voltage for relay operation and switching interfaces.
The documented coil operating range is 38.4 to 57.6 V DC, corresponding to 80% to 120% of the nominal supply voltage. At nominal voltage, the coil draws approximately 13.5 mA, with a rated power consumption of approximately 0.7 W.
These electrical characteristics allow the relay to be incorporated into appropriately rated industrial control circuits. The coil supply should remain within the manufacturer's specified limits, and the installation must account for supply tolerances, wiring conditions and any external switching devices.
The Finder 7S.14.9.048.4310 provides four mechanically linked relay contacts arranged as three normally open contacts and one normally closed contact.
The three normally open contacts can be used for appropriately rated switching functions, while the normally closed contact can provide feedback to a suitable safety monitoring circuit. The actual use of each contact must be determined by the system design and the required safety function.
Each contact has a rated current of 6 A, with a maximum combined current through the normally open contacts of 12 A, subject to the manufacturer's specified conditions.
The module also has a 250 V AC rated switching voltage and a specified resistive switching capacity of 1,500 VA. The permissible current may be lower for inductive loads, frequent switching or other demanding applications, so the relevant utilisation category and contact life characteristics should always be considered.
The Finder 7S.14.9.048.4310 is designed for installation on a standard 35 mm DIN rail in accordance with EN 60715. Its 22.5 mm nominal housing width makes it suitable for industrial control panels where multiple switching and monitoring devices must be installed within limited space.
The relay uses screwless spring-clamp terminals, allowing conductors to be connected without conventional screw terminals. When installed using the manufacturer's specified conductor types and preparation requirements, spring-clamp connections provide a convenient and secure wiring method.
An integrated LED coil status indicator provides visual confirmation when the relay coil is energised. This supports commissioning and fault diagnosis, although the LED does not independently confirm the condition of every contact or the safety state of the connected machinery.
The module has an IP20 protection rating and should be installed inside a suitable electrical enclosure. Its operating temperature range of −40 to +70 °C supports use in a wide range of industrial environments.
Finder Series 7S relays are designed for applications requiring forcibly guided contacts and monitored switching. These characteristics are useful in machinery safety systems, but the performance of the complete safety function depends on the circuit architecture, diagnostic coverage, component reliability and installation conditions.
The Finder Series 7S range includes devices suitable for applications up to SIL 2 according to IEC 61508, depending on the relay type and system design. Machinery safety systems may also be assessed according to EN ISO 13849-1.
When incorporating the Finder 7S.14.9.048.4310 into a safety-related control system, designers should verify the required Performance Level or Safety Integrity Level, contact loading, fault detection measures and response to component failure.
For emergency-stop circuits, machine guarding, safety interlocks and other protective functions, the relay should be used with suitable safety monitoring and control equipment where required. The complete system must be assessed and validated by a competent professional.
Tick the specs you need, then view products that match.
| Device Type | Positively Guided Relay | |
|---|---|---|
| Mounting Type | DIN rail | |
| Switching Current (A) | 6 A | |
| Load Voltage | 250 V AC | |
| Manufacturer | Finder | |
| Series | 7S | |
| Product code | 7S.14.9.048.4310 | |
| Product type | Modular relay with forcibly guided contacts | |
| Contact arrangement | 3 NO + 1 NC | |
| Number of contacts | 4 | |
| Contact guidance | Class A forcibly guided | |
| Contact guidance standard | EN 61810-3 | |
| Nominal coil voltage | 48 V DC | |
| Coil operating range | 38.4 to 57.6 V DC | |
| Rated coil current | 13.5 mA | |
| Rated coil power | 0.7 W | |
| Rated contact current | 6 A per contact | |
| Maximum combined NO contact current | 12 A | |
| Rated switching voltage | 250 V AC | |
| Rated resistive switching load (AC1) | 1,500 VA | |
| Contact material | Silver-nickel (AgNi) | |
| Contact configuration code | 4310 | |
| Operate time | Approximately 12 ms | |
| Release time | Approximately 10 ms | |
| Mechanical endurance | 10,000,000 operations | |
| Electrical endurance | 100,000 operations at specified AC1 rated load | |
| Electrical terminals | Screwless spring-clamp | |
| Coil indication | Integrated LED | |
| Mounting | DIN rail | |
| DIN rail size | 35 mm | |
| DIN rail standard | EN 60715 | |
| Nominal module width | 22.5 mm | |
| Ingress protection | IP20 | |
| Operating temperature | −40 to +70 °C | |
| Applicable contact guidance standard | EN 61810-3 | |
| Safety-related applications | Subject to complete system design and validation | |
| EAN / GTIN | 8012823420530 |
The Finder 7S.14.9.048.4310 is a 48 V DC modular relay with forcibly guided contacts, designed for industrial safety-related control systems, machinery automation and monitored switching applications.
The relay features a 3 normally open (NO) + 1 normally closed (NC) contact configuration, providing four mechanically linked contacts for switching and monitoring functions.
The Finder 7S.14.9.048.4310 operates with a 48 V DC nominal coil and has a specified coil operating range of 38.4 to 57.6 V DC.
Class A forcibly guided contacts are mechanically linked normally open and normally closed contacts designed so that they cannot simultaneously reach their closed positions under specified contact fault conditions. This supports fault detection within appropriately designed safety monitoring circuits.
The Finder 7S.14.9.048.4310 has a 6 A rated current per contact, with a maximum combined normally open contact current of 12 A, subject to the manufacturer's operating conditions.
The relay has a 250 V AC rated switching voltage. The permitted switching current depends on the load type and the applicable contact ratings.
Yes. The relay includes an integrated LED coil status indicator, allowing technicians to see when the relay coil is energised.
The Finder 7S.14.9.048.4310 uses screwless spring-clamp terminals for secure electrical connections without conventional screw terminals.
Yes. The relay is designed for mounting on a standard 35 mm DIN rail and has a compact 22.5 mm nominal module width.
The Finder 7S.14.9.048.4310 is designed for ambient operating temperatures from −40 to +70 °C, supporting use in demanding industrial electrical environments.
The relay has a specified mechanical endurance of 10 million operations. Actual service life depends on contact loading, switching frequency, environmental conditions and installation practices.
No. The Finder 7S.14.9.048.4310 is a relay module with forcibly guided contacts, not a standalone safety controller. It must be integrated into a correctly designed and validated safety-related control system where required.
Finder Series 7S relays are intended for safety-related applications, including applications up to SIL 2 according to IEC 61508 where the relevant type and complete system design support that level. The relay alone does not establish a SIL rating for the complete installation.
Both are four-contact Finder Series 7S relays with forcibly guided contacts and a 48 V DC coil. The 7S.14.9.048.4220 has a 2 NO + 2 NC contact configuration, while the 7S.14.9.048.4310 has a 3 NO + 1 NC arrangement.
Finder Series 7S relay modules combine Class A forcibly guided contact technology with compact DIN rail construction and dependable industrial switching performance. With a 48 V DC coil, 3 NO + 1 NC contact configuration, 6 A rated contacts, spring-clamp terminals and LED indication, the Finder 7S.14.9.048.4310 provides a practical relay component for appropriately designed machinery safety and automation systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.