Finder 7S.14.9.012.4310 - 7S Series Relay modules with forcibly guided contacts

Finder 7S.14.9.012.4310 – 7S Series Relay modules with forcibly guided contacts

Finder 7S.14.9.012.4310 is a 12 V DC electromechanical safety relay featuring four forcibly guided contacts in a 3 NO + 1 NC configuration, 6 A contact rating, LED indication and screwless DIN rail mounting for industrial safety-related control systems.

SKU: 7S.14.9.012.4310Alt SKU: 7S1490124310MPN: 7S.14.9.012.4310
Price
List Price £84.37 ex VAT
Your Price (ex VAT) Save 25%
£63.28 25% OFF
You save £21.09 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £63.28
Trade pricing is personalised to your account

Manufacturer Lead Time

£63.28

Why Choose the Finder 7S.14.9.012.4310 Safety Relay?

The Finder 7S.14.9.012.4310 is a compact and dependable electromechanical safety relay with forcibly guided contacts, designed for safety-related switching and monitoring applications in industrial machinery and automation systems. As part of the Finder 7S Series modular safety relay range, it provides reliable switching performance and mechanically linked contact operation for industrial safety control circuits.

This safety relay features four forcibly guided contacts arranged as 3 normally open (NO) and 1 normally closed (NC), providing three switching contacts and one feedback contact for appropriately designed safety-related circuits. Its mechanically linked contact system helps external monitoring equipment detect contact faults, including welded contacts, supporting dependable operation in industrial machinery safety applications.

With a 12 V DC operating coil, a 6 A rated contact current and a 250 V AC nominal switching voltage, the Finder 7S.14.9.012.4310 is suitable for industrial control panels, safety interface assemblies and machinery monitoring systems. Its compact modular construction, spring-loaded screwless terminals and integrated LED indicator simplify installation and maintenance within DIN rail-mounted electrical enclosures.

Key Advantages

  • Reliable electromechanical safety relay with forcibly guided contacts for industrial safety-related control circuits.
  • 3 NO + 1 NC contact configuration provides switching and feedback functionality.
  • 6 A rated contact current suitable for industrial control applications.
  • 12 V DC operating coil compatible with low-voltage DC control systems.
  • 250 V AC nominal contact switching voltage for appropriately rated electrical loads.
  • Mechanically linked contacts support contact fault detection and external safety monitoring.
  • Spring-loaded screwless terminals simplify wiring and provide secure electrical connections.
  • Integrated LED status indication enables convenient visual monitoring of relay energisation.
  • Compact DIN rail-mounted construction saves space inside industrial control cabinets.
  • Wide −40 to +70 °C operating temperature range supports demanding industrial environments.

Key Features

  • Finder 7S Series modular safety relay.
  • Forcibly guided electromechanical contacts for safety-related switching applications.
  • Four-pole contact arrangement: 3 normally open and 1 normally closed.
  • 12 V DC nominal coil voltage.
  • 6 A rated contact switching current.
  • 250 V AC nominal contact switching voltage.
  • 800 mW nominal coil power consumption.
  • 64.7 mA nominal coil current.
  • 185.5 Ω coil resistance.
  • 9.6 V DC must-operate voltage.
  • 1.2 V DC must-release voltage.
  • 12 ms typical operate time.
  • 10 ms typical release time.
  • Silver tin oxide (AgSnO) contact material for dependable switching.
  • Integrated LED indicator for relay coil status.
  • Spring-loaded screwless terminal connections.
  • 35 mm DIN rail mounting for industrial electrical enclosures.
  • IP20 protection rating.

Reliable Safety Switching for Industrial Machinery

Safety relays with forcibly guided contacts are important components in industrial safety-related control systems. Their mechanically linked contact construction ensures that normally open and normally closed contacts cannot simultaneously assume closed positions under specified fault conditions. This characteristic allows suitable external monitoring circuits to detect failures such as welded contacts and helps support the diagnostic functions required in machinery safety applications.

The Finder 7S.14.9.012.4310 features a 3 NO + 1 NC contact arrangement, making it particularly suitable for applications requiring multiple normally open switching paths and a normally closed feedback contact. The relay can be incorporated into safety interface assemblies, monitored switching arrangements and industrial automation control systems.

Its 12 V DC coil, 6 A contact rating and compact DIN rail-mounted construction make it convenient for electrical panel builders and machinery manufacturers. The integrated LED indicator assists with operational checks, while spring-loaded terminals support straightforward installation and servicing.

As an electromechanical safety relay, the 7S.14.9.012.4310 is intended to operate as a component within a properly engineered safety-related control system. The achievable safety performance level, diagnostic coverage and system reliability depend on the complete circuit architecture, external monitoring arrangements and application-specific safety assessment.

Typical Applications

  • Industrial machinery safety-related control circuits.
  • Emergency-stop switching arrangements with suitable external safety monitoring.
  • Safety relay interface assemblies and monitored switching systems.
  • Machine guarding and safety interlock feedback circuits.
  • Industrial automation and electrical control cabinets.
  • Safety-related contactor monitoring and auxiliary switching.
  • Manufacturing machinery and automated production lines.
  • Packaging machinery and material handling equipment.
  • OEM machine building and industrial control panel applications.
  • Safety-related control systems requiring forcibly guided relay contacts.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Positively Guided Relay
Terminal Type Spring clamp
Switching Current (A) 6 A
Mounting Type DIN rail
Manufacturer Finder
Series 7S Series
Model 7S.14.9.012.4310
Product type Electromechanical safety relay
Contact technology Forcibly guided contacts
Contact configuration 3 NO + 1 NC
Number of contacts 4
Contact form 4PST, 3 Form A + 1 Form B
Nominal coil voltage 12 V DC
Rated contact current 6 A
Nominal switching voltage 250 V AC
Nominal coil power 800 mW
Nominal coil current 64.7 mA
Coil resistance 185.5 Ω
Must-operate voltage 9.6 V DC
Must-release voltage 1.2 V DC
Operate time 12 ms
Release time 10 ms
Contact material Silver tin oxide (AgSnO)
Operating temperature −40 to +70 °C
Protection rating IP20
Mounting type DIN rail mounting
Terminal type Spring-loaded screwless terminals
Status indication Integrated LED indicator
Contact terminal arrangement 11–12, 23–24, 33–34, 43–44
Coil terminals A1 / A2
Weight approx. 118 g
Country of origin Italy
RoHS compliance Compliant

Frequently Asked Questions

What is the Finder 7S.14.9.012.4310 used for?

The Finder 7S.14.9.012.4310 is an electromechanical safety relay with forcibly guided contacts, designed for safety-related switching, contact monitoring and industrial machinery control applications.

What is the contact configuration of this safety relay?

The relay features four forcibly guided contacts arranged as 3 normally open (NO) and 1 normally closed (NC), providing three switching paths and one feedback contact for appropriately designed safety-related circuits.

What coil voltage does the Finder 7S.14.9.012.4310 require?

The relay operates from a 12 V DC coil supply, with a nominal coil power consumption of 800 mW and a nominal coil current of approximately 64.7 mA.

What is the rated contact current and switching voltage?

The Finder 7S.14.9.012.4310 has a 6 A rated contact current and a 250 V AC nominal switching voltage. The permissible switching load depends on the electrical utilisation category and operating conditions.

What are forcibly guided contacts and why are they important?

Forcibly guided contacts are mechanically linked normally open and normally closed contacts designed to prevent both contact types from being closed simultaneously under specified fault conditions. This enables suitable external monitoring circuits to detect contact failures, including welded contacts.

Does the Finder 7S.14.9.012.4310 include an LED indicator?

Yes. The relay features an integrated LED status indicator that provides visual indication of coil energisation, making operational checks and fault investigation easier.

How is the Finder 7S.14.9.012.4310 installed?

The relay is designed for DIN rail mounting inside suitable electrical control cabinets. Its spring-loaded screwless terminals allow convenient wiring without conventional screw terminal connections.

Trusted Safety Relay Technology from Finder

Finder 7S Series safety relays combine forcibly guided contact technology, dependable electromechanical switching and compact DIN rail construction to support industrial automation engineers and machine builders developing reliable safety-related control systems.